BBGVX - DELTRON CATALYST, DAU2

Product Identification

Product ID:DELTRON CATALYST, DAU2
MSDS Date:01/01/1985
FSC:8010
NIIN:00F000533
MSDS Number: BBGVX

Responsible Party
PPG INDUSTRIES, INC. COATINGS & RESINS DIVISION

Emergency Phone: 304/ 843-1300

Cage: DO894

Contractor
PPG INDUSTRIES, INC.
9 ALLISON PARK, PA 15101 US

Telephone: 412-592-5555

Cage: DO894

Ingredients

ISOPHORONE DIISOCYANATE (SARA III)

CAS: 4098-71-9

RTECS: NQ9370000

Fraction By Weight: <5%

OSHA PEL S 0.005PPM/0.02STEL

ACGIH TLV: 0.005 PPM; 9394


2-ETHOXYETHYL ACETATE (CELLOSOLVE ACETATE) (EGEEA)

CAS: 111-15-9

RTECS: KK8225000

Fraction By Weight: 30%

OSHA PEL S,100 PPM

ACGIH TLV: S, 5 PPM; 9192


ISOBUTYL ACETATE (SARA III)

CAS: 110-19-0

RTECS: AI4025000

Fraction By Weight: 10%

OSHA PEL 150 PPM

ACGIH TLV: 150 PPM; 9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


N-BUTYL ACETATE (SARA III)

CAS: 123-86-4

RTECS: AF7350000

Fraction By Weight: 10%

OSHA PEL 150 PPM/200 STEL

ACGIH TLV: 150 PPM/200STEL;9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


XYLENES (O-,M-,P- ISOMERS) (SARA III)

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 5 - 10%

OSHA PEL 100 PPM/150 STEL

ACGIH TLV: 100 PPM/150STEL;9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

Effects of Overexposure:HARMFUL IF INHALED OR ABSORBED THROUGH SKIN;
MAY CAUSE LUNG IRRITATION OR ALLERGIC REACTION

First Aid

First Aid:VAPOR: REMOVE TO FRESH AIR. IF BREATHING DIFFICULTY PERSISTS,
CONSULT PHYSICIAN. EYES: FLUSH IMMEDIATELY WITH PLENTY OF WATER FOR
15 MINUTES. CALL A PHYSICIAN. SKIN: WASH THOROUGHLY WITH SOAP &
WATER.

Fire Fighting

Flash Point:24 F, PMCC
Lower Limits:2.1
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL OR FOAM
Fire Fighting Procedures:WATER SPRAY MAY BE USED TO COOL CLOSED
CONTAINERS
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY EXPLODE WHEN
EXPOSED TO EXTREME TEMPERATURES.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. AVOID
BREATHING VAPORS. VENTILTATE AREA. REMOVE WITHNERT ABSORBENT AND
NON-SPARKING TOOLS.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 120F. STORE LARGE
QUANTITIES IN BUILDINGS DESIGNED AND PROTECTED FOR STORAGOF CLASS
IB FLAMMABLE LIQUIDS.
Other Precautions:DO NOT TAKE INTERNALLY. CONTAINERS SHOULD BE GROUNDED
WHEN POURING. AVOID FREE FALL OF LIQUID IN EXCESS OF A FEW INCHES.
DO T FLAME CUT, BRAZE OR WELD WITHOUT APPROVED RESPIRATORS.

Exposure Controls

Respiratory Protection:POSITIVE PRESSURE AIR SUPPLIED RESPIRATOR
Ventilation:GENERAL DILUTION OR LOCAL EXHAUST
Protective Gloves:REQUIRED
Eye Protection:REQUIRED
Other Protective Equipment:IMPERVIOUS CLOTHING
Supplemental Safety and Health
ONE GATEWAY CENTER - PITTSBURGH, PA 15222. PRODUCT ALSO CONTAINS
POLYMERIC ISOCYANATE (20%), ETHYL ACETATE (15%), ALIPHAT
HYDROCARBON (10%).

Chemical Properties

Boiling Pt:B.P. Text:75-156PPM
Vapor Density:>AIR
Evaporation Rate & Reference:< ETHER
Percent Volatiles by Volume:85

Stability

Stability Indicator/Materials to Avoid:YES
WATER, ALCOHOLS, AND STRONG BASES
Hazardous Decomposition Products:CARBON DIOXIDE, HYDROGEN CYANIDE,
ISOPHORONE DIISOCYANATE

Disposal

Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS. DO NOT INCINERATE CLOSED CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.