BBKKV - 50C3 LAMINAR X-500 HARDENER

Product Identification

Product ID:50C3 LAMINAR X-500 HARDENER
MSDS Date:05/26/1993
FSC:8010
NIIN:00F002153
MSDS Number: BBKKV

Responsible Party
DEXTER CROWN METRO AEROSPACE COATINGS
31500 HAYMAN ST
HAYWARD, CA 94544-7120
US

Emergency Phone: 803-277-1870

Info Phone: 510-471-7171

Cage: 0S4B8

Contractor
DEXTER CORP THE DEXTER CROWN METRO AEROSPACE DIV
HAYWARD, CA 94544-7120 US

Telephone: 510-471-7171

Cage: 98795

Ingredients

XYLENE, DIMETHYLBENZENE, XYLOL

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 10-20%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPM, SKIN

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


9.350

RTECS: 9999999WG


3.7 LBS/GAL LESS WATER

RTECS: 9999999VO


1,6-HEXAMETHYLENE DIISOCYANATE, TOLUENE DIISOCYANATE

CAS: 63368-95-6

Fraction By Weight: 50-60%


TOLUENE DIISOCYANATE (ANIMAL CARCINOGEN BY NTP)

CAS: 26471-62-5

RTECS: HQ9490000

Fraction By Weight: <10%

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


PROPYLENEGLYCOL MONOMETHYL ETHER ACETATE,

CAS: 108-65-6

RTECS: AI8925000

Fraction By Weight: 20-30%

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: RESPIRATORY IRRITATION.
EYES: IRRITATION. SKIN: IRRITATION & SENSITIVITY. MAY BE ABSORBED
THROUGH THE EYES, SKIN, INHALATION & INGESTION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INHALATION: HEADACHE, DIZZINESS OR DROWSINESS.
Medical Cond Aggravated by Exposure:RESPIRATORY PROBLEMS

First Aid

First Aid:INHALATION: REMOVE TO FRESH AIR. EYES: FLUSH W/PLENTY OF
WATER FOR AT LEAST 15 MINS. SKIN: REMOVE CONTAMINATED CLOTHING &
WASH W/SOAP & WATER. INGESTION: DRINK WATER. OBTAIN MEDICAL
ATTENTION IN ALL C ASES.

Fire Fighting

Flash Point Method:SCC
Flash Point:92F
Lower Limits:1.10%
Extinguishing Media:WATER FOG, FOAM, DRY CHEMICAL OR CO2
Unusual Fire/Explosion Hazard:FLAMMABLE LIQUID

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE
AREA. REMOVE W/INERT ABSORBENT & NON-SPARKING TOOLS.

Handling

Handling and Storage Precautions:GROUND CONTAINERS WHEN POURING. AVOID
FREE FALL OF LIQUID IN EXCESS OF A FEW INCHES. DRUM MUST BE
COMPLETELY EMPTY BEFORE ATTEMPTING TO WELD OR BRAZE.
Other Precautions:DON'T TAKE INTERNALLY. DRUM SHOULD BE INDUSTRIALLY
CLEANED PRIOR TO REUSE. DON'T FLAME CUT, BRAZE OR WELD W/OUT A
NIOSH APPRVED RESPIRATOR OR APPROPRIATE VENTILATION. KEEP CONTAINER
CLOSED WHEN NOT IN USE.

Exposure Controls

Respiratory Protection:PROPERLY FITTED RESPIRATOR NIOSH/OSHA APPROVED
WHEN EXPOSED. RECOMMEND AIR LINE RESPIRATOR (TC19C NIOSH/MSHA).
VAPOR/PARTICULATE RESPIRATOR (TC23C NIOSH/MSHA) MAY BE APPROPRIATE
WHEN EXPOSURE OF ISOCY ANATES IS 10 TIMES LESS THE TLV.
Ventilation:PROVIDE GENERAL DILUTION OR LOCAL EXHAUST TO KEEP BELOW TWA
& LEL & TO REMOVE DECOMPOSITION PRODUCTS.
Protective Gloves:CHEMICAL RESISTANT
Eye Protection:SAFETY GLASSES
Work Hygienic Practices:REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE.
Supplemental Safety and Health

Chemical Properties

Boiling Pt:B.P. Text:280-484F
Vapor Density:>1

Stability

Stability Indicator/Materials to Avoid:NO
WATER OR WATER CONTAINING PRODUCTS
Stability Condition to Avoid:SOURCES OF IGNITION
Hazardous Decomposition Products:CO, OXIDES OF NITROGEN, HEAT & FUMES.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/LOCAL, STATE, &
FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.