BBYYP - EXIDE BATTERY IRONCLAD

  • MSDS: BBYYP
  • Manufacturer: EXIDE CORP
  • Product Name: EXIDE BATTERY IRONCLAD
  • National Stock Number: 6140-00F007964
Product Identification

Product ID:EXIDE BATTERY IRONCLAD
MSDS Date:05/31/1986
FSC:6140
NIIN:00F007964
MSDS Number: BBYYP

Responsible Party
EXIDE CORPORATION
101 GIBRALTAR RD.
HORSHAM, PA 19044

Emergency Phone: (215) 441-7531

Info Phone: (215) 441-7531

Cage: 60038

Contractor
TIMKEN CORP GOVERNMENT SALES BON-17
14205 CANTON, OH 44706-2798 US

Telephone: 330-471-6587/330-471-6470 FAX

Cage: 60038

Ingredients

LEAD (SARA III)

CAS: 7439-92-1

RTECS: OF7525000

Fraction By Weight: 70-75%

OSHA PEL 0.05 MG/M3;1910.1025

ACGIH TLV: 0.15 MG/M3;DUST 9192

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


ANTIMONY (SARA III)

CAS: 7440-36-0

RTECS: CC4025000

Fraction By Weight: 1-10%

OSHA PEL 0.5 MG/M3

ACGIH TLV: 0.5 MG SB/M3; 9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ARSENIC (SARA III)

CAS: 7440-38-2

RTECS: CG0525000

Fraction By Weight: 1.0%

OSHA PEL 0.5 MG/M3 (AS)

ACGIH TLV: 0.01,A1 MG/M3; 9394

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


SULFURIC ACID (SARA III)

CAS: 7664-93-9

RTECS: WS5600000

Fraction By Weight: 10-30%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3; 9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NO POSSIBILITY OF OVEREXPOSURE TO
LEAD, ETC. UNLESS BATTERY IS DESTROYED. SULFURIC ACID MIST CAUSES
COUGHING & WILL BURN EYES & SKIN.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:CAUSES COUGHING & WILL BURN EYES & SKIN.

First Aid

First Aid:EYES/SKIN: FLUSH WITH WATER FOR AT LEAST 15 MIN. - SEE
PHYSICIAN.

Fire Fighting

Lower Limits:4.0%
Upper Limits:74.2%
Extinguishing Media:CO2, DRY CHEMICAL - HALOGEN TYPE.
Fire Fighting Procedures:WHEN HALOGEN TYPE EXTINGUISHER IS USED PROMPT
EVACUATION AND/OR RESCUE OF TRAPPED PERSONNEL IS NEEDED.
Unusual Fire/Explosion Hazard:WILL GENERATE HYDROGEN & SULFURIC ACID
MIST ON OVERCHARGE.

Accidental Release

Spill Release Procedures:WASH WITH WATER.
Neutralizing Agent:NEUTRALIZE WITH SODIUM CARBONATE OR BICARBONATE.

Handling

Handling and Storage Precautions:KEEP AWAY FROM FLAMES DURING &
IMMEDIATELY AFTER CHARGE. DON'T SHORT BATTERY WITH TOOLS, ETC.
Other Precautions:AVOID PROLONGED OVERCHARGE IN CONFINED AREAS.

Exposure Controls

Respiratory Protection:HALF MASK WITH DUST & MIST FILTER.
Ventilation:LOCAL EXHAUST: CHANGE AIR IN ROOM 3-4 TIMES PER/HOUR.
Protective Gloves:RUBBER
Eye Protection:GOGGLES, FACESHIELD
Other Protective Equipment:RUBBER APRON
Supplemental Safety and Health

Stability

Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:PROLONGED OVERCHARGING IN CONFINED SPACES.
Hazardous Decomposition Products:HYDROGEN, ARSINE OR STIBINE ON
OVERCHARGE ONLY
Conditions to Avoid Polymerization:KEEP AWAY FROM FLAMES.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,