BCKNY - PROXON 19122

  • MSDS: BCKNY
  • Manufacturer: EUTECTIC CORP
  • Product Name: PROXON 19122
  • National Stock Number: 3439-00N003668
Product Identification

Product ID:PROXON 19122
MSDS Date:01/01/1985
FSC:3439
NIIN:00N003668
MSDS Number: BCKNY

Responsible Party
EUTECTIC CORPORATION

Emergency Phone: 212-358-4000

Cage: EO060

Contractor
EUTECTIC CORPORATION
CHARLOTTE, NC 28273 US

Telephone: 704-527-9800/ 800-221-1433

Cage: EO060

Ingredients

CHROMIUM (SARA III)

CAS: 7440-47-3

RTECS: GB4200000

Fraction By Weight: 2.5%

OSHA PEL 1 MG/M3

ACGIH TLV: 0.5 MG/M3; 9192

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


NICKEL (SARA III)

CAS: 7440-02-0

RTECS: QR5950000

Fraction By Weight: >50%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3; 9192


IRON OXIDE

CAS: 1309-37-1

RTECS: NO7400000

Fraction By Weight: <1%

OSHA PEL 10 MG/M3 (FE)

ACGIH TLV: 5 MG/M3(FE),B2; 9293


MOLYBDENUM

CAS: 7439-98-7

RTECS: QA4680000

Fraction By Weight: 2.5%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3; 9293


ALUMINUM (SARA III)

CAS: 7429-90-5

RTECS: BD0330000

Fraction By Weight: 2.5%

OSHA PEL 15MG/M3 DUST/5 FUME

ACGIH TLV: 10MG/M3 DUST; 9192

Hazards

Effects of Overexposure:VAPORS IN CONFINED AREA MAY BE HARMFUL.

First Aid

First Aid:INHALATION: REMOVE TO WELL VENTILATED AREA,OBTAIN MEDICAL
ASSISTANCE IF NECESSARY.

Accidental Release

Spill Release Procedures:NORMAL HOUSEKEEPING MAY BE VACUUM CLEANED.

Handling

Handling and Storage Precautions:REFER TO AWS C2.1-1973,RECOMMENDED
SAFE PRACTICES FOR THERMAL SPARYING.

Exposure Controls

Respiratory Protection:AIR SUPPLIED TYPE IN CONFINED AREA.
Ventilation:LOCAL EXHAUST
Eye Protection:GOGGLES./PROTECT SHIELD
Other Protective Equipment:REFER TO AWS PUBLICATION-AWS C2,1-1973.
Supplemental Safety and Health
ADD INGREDIENTS: CARBON <1%,TLV: 10 MG/CUM; BORON <1%,TLV:10MG/CUM;
SILICON <1%,TLV: 10 MG/CUM.

Stability

Stability Indicator/Materials to Avoid:YES

Disposal

Waste Disposal Methods:NORMAL INDUSTRIAL WASTE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.