BCQRZ - SODIUM IDIDE (5086,3751,3748,3750)

  • MSDS: BCQRZ
  • Manufacturer: J T BAKER CHEMICAL CO
  • Product Name: SODIUM IDIDE (5086,3751,3748,3750)
  • National Stock Number: 6810-00N008619
Product Identification

Product ID:SODIUM IDIDE (5086,3751,3748,3750)
MSDS Date:08/15/1986
FSC:6810
NIIN:00N008619
MSDS Number: BCQRZ

Responsible Party
J.T. BAKER CHEMICAL CO.
222 RED SCHOOL LANE
PHILLIPSBURG, NJ 08865

Emergency Phone: 201-859-2151 (24 HOURS)

Info Phone: 201-859-2151

Cage: 5B970

Contractor
MALLINCKRODT BAKER, INC.
PHILLIPSBURG, NJ 08865 US

Telephone: 800-582-2537

Cage: 70829

Ingredients

SODIUM IODIDE

CAS: 7681-82-5

RTECS: WB6475000

Fraction By Weight: 90-100%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:LD50 ORAL RAT 4340 MG/KG (SEE SUPP DATA)
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:N/K
Explanation of Carcinogenicity:NONE
Effects of Overexposure:EYES: MAY CAUSE IRRITATION.SKIN:MAY CAUSE
IRRITATION.INHALATION:N/K INGESTION:N/K :Medical Cond Aggravated
by Exposure:N/K (ORNL)

First Aid

First Aid:CALL A PHYSICIAN.EYES:IMMEDIATELY FLUSH WITH PLENTY OF WATER
FOR AT LEAST 15 MIN.SKIN:FLUSH WITH WATER.INGESTION:IF
CONCIOUS,IMMEDIATELY INDUCE VOMITING.INHALATION:REMOVE TO FRESH
AIR.SUPPORT BREATHIN G (GIVE O*2/ARTIFICIAL RESP) .

Fire Fighting

Extinguishing Media:USE MEDIA APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:HAZARDOUS DECOMP PRODUCTS:IODINES.

Accidental Release

Spill Release Procedures:WEAR SCBA AND FULL PROTECTIVE CLOTHING.WITH
CLEAN SHOVEL,CAREFULLY PLACE MATERIAL INTO CLEAN,DRY CONTAINER AND
COVER;REMOVE FROM AREA WITH WATER.
Neutralizing Agent:N/K

Handling

Handling and Storage Precautions:KEEP PRODUCT OUT OF LIGHT.KEEP
CONTAINER TIGHTLY CLOSED.PRODUCT IS SUITABLE FOR ANY GENERAL
CHEMICAL STORAGE AREA.
Other Precautions:AVOID CONTACT WITH EYES,SKIN,CLOTHING.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APROPRIATE FOR
EXPOSURE PF CONCERN .NONE REQUIRED WHERE PROPER VENTILATION EXISTS.
Ventilation:LOCAL AND GENERAL VENTILATION NECESSARY TO KEEP AIR
CONCENTRATION BELOW LEVELS OF CONCERN .
Protective Gloves:RECOMMENDED.
Eye Protection:CHEMICAL WORKERS GOGGLES
Other Protective Equipment:WEAR UNIFORM OR LAB COAT.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
LD50 IP MOUSE 869 MG/KG.SAF-T-DATA*TM
SYSTEM:HEALTH-1(SLIGHT);FLAMMABILITY-0(NONE);REACTIVITY-1(SLIGHT);C
ONTACT-2(MODERTE).

Chemical Properties

Boiling Pt:B.P. Text:1304C,2379F
Melt/Freeze Pt:M.P/F.P Text:651C,1204F
Decomp Temp:Decomp Text:N/K
Spec Gravity:3.6 (WATER=1)
Solubility in Water:APPRECIABLE (>10%)
Appearance and Odor:WHITE ODORLESS CRYSTALS.
Percent Volatiles by Volume:0

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS,BROMINE TRIFLUORIDE AND TRICHLORIDE.
Stability Condition to Avoid:LIGHT
Hazardous Decomposition Products:IODINE,OXIDES
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH
FEDERAL,STATE AND LOCAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.