BCSKB - LIQUID PAPER PEN AND INK CORRECTION FLUID

Product Identification

Product ID:LIQUID PAPER PEN AND INK CORRECTION FLUID
MSDS Date:01/06/1986
FSC:7510
NIIN:00N009423
MSDS Number: BCSKB

Responsible Party
GILLETTE MEDICAL EVALUATION LABORATORIES
1413 RESEARCH BOULEVARD
ROCKVILLE, MD 20850

Emergency Phone: 301-424-2000

Info Phone: 301-424-2000

Cage: 9A977

Contractor
GILLETTE MEDICAL EVALUATION LABORATORIES
ROCKVILLE, MD 20850

Telephone: 301-424-2000

Cage: 9A977

Ingredients

METHYL CHLOROFORM (1,1,1-TRICHLOROEHANE) (SARA III)

CAS: 71-55-6

RTECS: KJ2975000

Fraction By Weight: Fraction by Wt

OSHA PEL 350 PPM/450 STEL

ACGIH TLV: 350 PPM/450STEL;9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


TITANIUM DIOXIDE

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: Fraction by Wt

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


RESINS, DISPERSANTS, COLORANTS

Fraction By Weight: Fraction by Wt

OSHA PEL N/K

ACGIH TLV: N/K


MUSTARD OIL

CAS: 57-06-7

RTECS: NX8225000

Fraction By Weight: Fraction by Wt

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:LD50 IN RATS= >5 ML/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL:NONE ANTICIPATED UNDER
FORESEEABLE USE CONDITION. INGEST:NONE ANTICIPATED UNDER
FORESEEABLE USE CONDTN. SKIN:NONE ANTICIPATED UNDER FORESEEABLE USE
CONDTN. IRRIT MAY OCCUR IF CONTACT IS PRLNG/RP TD. SOLVENT CAN BE
ABSORB THROUGH SKIN (PRLNG CONTACT),BUT NOT LIKELY IN TOXIC AMTS.
EYE:IRRITATION. (SEE SUPP DATA).
Explanation of Carcinogenicity:N/A
Effects of Overexposure:INHAL:IF VAPORS ARE DELIBERATELY CONCENTRATED &
INHALED (ABUSE) FOLLOWING SYMPTOMS MAY OCCUR: RESPIRATORY IRRIT,
DIZZINESS, DROWSINESS HDCH, NAUS, UNCON, CARDIAC SENSITIZATION,
COMA & DEATH. (MUSTTARD OIL IS ADDED TO THE PROD AS AN ABUSE
DETERRENT).INGEST:DEPEND ON AMT INGEST MOST SYMP DESCRIBED ABOVE
MAY OCCUR.
Medical Cond Aggravated by Exposure:N/A

First Aid

First Aid:EYES:FLUSH W/PLENTY OF H*2O FO 15 MIN. IF IRRIT PERSISTS
OBTAIN MED ATTN. SKIN:WASH W/SOAP & H*2O. INHAL:NONE NORM
ANTICIPATED. IN ABUSE SITUATION RMV TO FRESH AIR & CONSULT
PHYSICIAN IMMEDIATELY. ING EST CONSULT PHYSICIAN. NOTES TO
PHYSICIAN: DO NOT USE SYMPATHOMIMETIC AGENTS (E.G. EPINEPHRINE) IN
HALOGENATED HYDROCARBON POISONING BECAUSE OF POSSIBLE INDUCTION OF
VENTRICULAR FIBRILLATION.

Fire Fighting

Flash Point:NONE
Lower Limits:8.0
Upper Limits:10.5
Extinguishing Media:AS FOR ADJACENT FIRE, DRY DHEMICAL, FOAM, CARBON
DIOXIDE
Fire Fighting Procedures:WEAR PRESSURE DEMAND SCBA & FIRES INVOLVING
LARGE QUANTITIES OF PRODUCT USE SCBA (MFR).
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE HCL AND PHOSGENE . HAZARDOUS DECOMPOSITION PRODUCTS.

Accidental Release

Spill Release Procedures:PICK UP SPILLS WITH TOWELS, TISSUES, ETC. AND
PLACE IN TRASH.
Neutralizing Agent:N/K

Handling

Handling and Storage Precautions:NO UNUSUAL HANDLING OR STORAGE WHEN
USED AS DIRECTED; WHEN STORED IN LARGE QUANTITIES (AS IN
WAREHOUSE), IT SHOULD BE IN A WELL-VENTILATED, COOL AREA.
Other Precautions:.

Exposure Controls

Respiratory Protection:NONE UNDER NORMAL USE CONDITIONS.(MFR).
NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN
Ventilation:NONE UNDER NORMAL USE CONDITIONS.
Protective Gloves:NONE UNDER NORMAL USE CONDITIONS
Eye Protection:NONE UNDER NORMAL USE CONDITIONS
Other Protective Equipment:PRODUCT IS NON-HAZARDOUS WHEN USED AS
DIRECTED IN AN OFFICE/ROOM WITH NORMAL AIR CIRCULATION.
Work Hygienic Practices:N/K
Supplemental Safety and Health
PCT VOLT-VOL: FP N. HEALTH HAZARDS:ACCORDING TO NIOSH POCKET GUIDE
1985, 1,1,1-TRICHLOROETHANE MAY CAUSE CARDIAC ARRHYTHMIAS .
NOTE:PHYSICAL DATA REFERS TO SOLVENT. CARCINOGENITY:FP N.

Chemical Properties

Boiling Pt:B.P. Text:165 F (74C)
Decomp Temp:Decomp Text:N/K
Vapor Pres:100 MMHG
Vapor Density:N/K
Spec Gravity:1.32
Evaporation Rate & Reference:ETHER=1, APPROX 2.7
Solubility in Water:<1%
Appearance and Odor:WHITE OR COLORED FLUID, SOLVENT ODOR
Corrosion Rate:

Stability

Stability Indicator/Materials to Avoid:YES
FOR SOLVENT CAUSTICS, ALUMINUM, BARIUM, MAGNESIUM,ZINC, SODIUM,
POTASSIUM.
Hazardous Decomposition Products:HCL, PHOSGENE . THERMAL DEGRADATION,
E.G. OPEN FLAME, CAN PRDCE SM AMTS OF PHOSGENE, HYDROGEN CHLORIDE &
CHLORINE.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN A/W FED, STATE & LCL
REGULATIONS . DISPOSE AS REGULA TRASH (MFR).

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.