BCSQC - CABLE CLEAN AEROSOL 2069

  • MSDS: BCSQC
  • Manufacturer: CRC CHEMICALS
  • Product Name: CABLE CLEAN AEROSOL 2069
  • National Stock Number: 6850-00N009516
Product Identification

Product ID:CABLE CLEAN AEROSOL 2069
MSDS Date:11/01/1985
FSC:6850
NIIN:00N009516
MSDS Number: BCSQC

Responsible Party
CRC CHEMICALS
885 LOUIS DRIVE
WARMINSTER, PA 18974

Emergency Phone: 215 674-4300

Info Phone: 215 674-4300

Cage: CRCCE

Contractor
CRC INDUSTRIES, INC.
WARMINSTER, PA 18974-2820 US

Telephone: 215-674-4300/800-424-9300

Cage: 10136

Ingredients

METHYL CHLOROFORM (1,1,1-TRICHLOROEHANE) (SARA III)

CAS: 71-55-6

RTECS: KJ2975000

Fraction By Weight: 72%

OSHA PEL 350 PPM/450 STEL

ACGIH TLV: 350 PPM/450STEL;9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


PERCHLOROETHYLENE (TETRACHLOROETHYLENE) (SARA III)

CAS: 127-18-4

RTECS: KX3850000

Fraction By Weight: 24%

OSHA PEL 100 PPM

ACGIH TLV: 25PPM/100,A3 STEL;94

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


CARBON DIOXIDE

CAS: 124-38-9

RTECS: FF6400000

Fraction By Weight: 4%

OSHA PEL 5000 PPM

ACGIH TLV: 5000PPM/30000STEL;93

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and
Chronic:ACUTE:INHALE:HEADACHE,DIZZINESS,ANESTHESIA,UNCONSCIOUSNESS.
EYES:CAUSES PAIN AND IRRITATION.SKIN:CAUSES IRRITATION ON REPEATED
EXPOSURE.CHRONIC:REPEATED OVEREXPOSURE MAY CAUSE LIVER AND KIDNEY
EFFECTS.
Explanation of Carcinogenicity:NA
Effects of Overexposure:INHALE:HEADACHE, DIZZINESS, ANESTHESIA,
UNCONSCIOUSNESS. EYE:CAUSES PAIN AND SOME IRRITATION. SKIN:CAUSES
IRRITATION ON REPEATED EXPOSURES.
Medical Cond Aggravated by Exposure:MAY CAUSE LIVER AND KIDNEY EFFECTS.
HIGH LEVELS (8000PPM+) OF VAPOR MAY CAUSE CARDIAC ARRTHYMIAS.

First Aid

First Aid:INHALE:REMOVE TO FRESH AIR,APPLY ARTIFICIAL RESPIRATION IF
NECESSARY. EYES:FLUSH FOR 15 MINUTES WITH LARGE AMOUNTS OF WATER.
SKIN:REMOVE CONTAMINATED CLOTHING,WASH EXPOSED SKIN WITH SOAP AND
WATER. IN GEST:DO NOT INDUCE VOMITING,CALL A PHYSICIAN.

Fire Fighting

Flash Point Method:TCC
Flash Point:NONE
Lower Limits:7.5
Upper Limits:14.5
Extinguishing Media:WATER FOG
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT.
Unusual Fire/Explosion Hazard:AEROSOLS MAY EXPLODE IF THEIR TEMPERATURE
EXCEEDS 130F/54.4C

Accidental Release

Spill Release Procedures:USUALLY NOT A PROBLEM WITH AEROSOLS-AREA
SHOULD BE VENTILATED AND ABSORBENT USED TO PICK UP EXCESS MATERIAL.

Handling

Handling and Storage Precautions:STORE IN A COOL DRY AREA.
Other Precautions:AVOID PROLONGED SKIN CONTACT OR BREATHING OF
VAPORS.SINCE VAPORS ARE HEAVIER THAN AIR,AEROSOLS SHOULD NOT BE
USED IN CONFINED AREAS OR LOW SPOTS WITHOUT ADEQUATE VENTILATION.
IF VAPORS ARE SUSPECTED I N A LOW AREA DO NOT ENTER(SEE SUPP DATA)

Exposure Controls

Respiratory Protection:ABOVE TLV USE SELF-CONTAINED AIR MASK OR VAPOR
MASK.(MFG) NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE
OF CONCERN.
Ventilation:MAINTAIN VAPOR CONCENTRATION BELOW TLV. USE MECHANICAL
MEANS IF NECESSARY.
Protective Gloves:SOLVENT RESISTANT
Eye Protection:SAFETY GLASSES/CHEMICAL WORKERS GOGGLES
Other Protective Equipment:NOT NORMALLY REQUIRED FOR AEROSOL PRODUCTS
Work Hygienic Practices:OBSERVE GOOD WORK HYGIENIC PRACTICES
Supplemental Safety and Health
BP:73.8-122.2C FP:TOC,COC OTHER PREC:UNLESS SPECIAL BREATHING APPARATUS
IS USED AND AN OBSERVER IS PRESENT FOR ASSISTANCE. KEEP AEROSOLS
AWAY FROM HEAT.

Chemical Properties

Boiling Pt:B.P. Text:165-252F
Vapor Pres:85MM
Vapor Density:4.8(AIR=1)
Spec Gravity:1.385@77F/25C
Evaporation Rate & Reference:RAPID(MFG)
Solubility in Water:SLIGHTLY SOLUBLE
Appearance and Odor:COLORLESS LIQUID-IRRITATING ODOR AT HIGH CONC.
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
AVOID STORAGE IN ALUMINUM CONTAINERS OR CONTACT WITH ALUMINUM AND ZINC
POWDER.
Stability Condition to Avoid:AVOID EXPOSURES TO OPEN FLAMES,ARCS,AND
HIGH TEMPERATURES.
Hazardous Decomposition Products:THERMAL-HYDROGEN CHLORIDE,CHLORINE,
AND SOME PHOSGENE.

Disposal

Waste Disposal Methods:DISCARDED FILLED CANS OR PARTIALLY USED CANS ARE
HAZARDOUS WASTE-DISPOSE OF IN CONFORMANCE TO
REGULATIONS.(MFG)DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL,STATE
AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.