BDDQG - YELLOW #13538 793-310

Product Identification

Product ID:YELLOW #13538 793-310
MSDS Date:01/01/1985
FSC:8010
NIIN:00-162-7525
MSDS Number: BDDQG

Responsible Party
AMERON INDUSTRIAL COATINGS DIVISION
201 N BERRY ST
BREA, CA 92621-3904
US

Emergency Phone: 714-529-4597

Info Phone: 714-529-4597

Cage: 09869

Contractor
AMERON INDUSTRIAL COATINGS DIVISION
BREA, CA 92621-3904 US

Telephone: 714-529-4597

Cage: 09869

Ingredients

NAPHTHA (PETROLEUM SPIRITS OR BENZIN)

CAS: 8030-30-6

RTECS: SE7555000

Fraction By Weight: 18%

OSHA PEL 100 PPM


TOLUENE (SARA III)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 0-10%

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ISOBUTYL ALCOHOL (SARA III)

CAS: 78-83-1

RTECS: NP9625000

Fraction By Weight: 14%

OSHA PEL 100 PPM

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ISOBUTYL ACETATE (SARA III)

CAS: 110-19-0

RTECS: AI4025000

Fraction By Weight: 24%

OSHA PEL 150 PPM

ACGIH TLV: 150 PPM; 9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ISOPROPYL ALCOHOL (SARA III)

CAS: 67-63-0

RTECS: NT8050000

Fraction By Weight: <5.0%

OSHA PEL 400 PPM/500 STEL

ACGIH TLV: 400 PPM/500STEL;9192

Hazards

Effects of Overexposure:INHALATION: ANESTHETIC, IRRITATION OF THE
RESPIRATORY TRACT OR ACUTE NERVOUS SYSTEM DEPRESSION.

First Aid

First Aid:IN CASE OF CONTACT, FLUSH SKIN AND EYES WITH PLENTY OF WATER
WHILE REMOVING CONTAMINATED CLOTHING. IF INHALED, REMOVE TO FRESH
AIR. CALL A PHYSICIAN IF SYMPTOMS PERSIST.

Fire Fighting

Flash Point:28FT.C.C
Lower Limits:.9
Extinguishing Media:USE CARBON DIOXIDE OR DRY CHEMICAL FOR SMALL FIRES.
Fire Fighting Procedures:SELF-CONTAINED BREATHING APPARATUS SHOULD BE
AVAILABLE.
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS EXPOSED TO HEAT MAY
EXPLODE DUE TO PRESSURE BUILD-UP.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION (FLAMES, HOT
SURFACES, AND ELECTRICAL, STATIC, OR FRIIONAL SPARKS). AVOID
BREATHING VAPORS. VENTILATE AREA. REMOVE WITH INERTBSORBENT AND
NON-SPARKING TOOLS.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 120F. STORE LARGE
QUANTITIES IN BUILDINGS DESIGNED AND PROTECTED FOR STORAGOF NFPA
CLASS 1 FLAMMABLE (OR COMBUSTIBLE) LIQUID.
Other Precautions:DO NOT TAKE INTERNALLY. CONTAINERS SHOULD BE GROUNDED
WHEN POURING. AVOID FREE FALL OF LIQUID IN EXCESS OF A FEW INCHES.
DO T FLAME CUT, BRAZE OR WELD COATED MATERIAL W/OUT RESPIRATOR.

Exposure Controls

Respiratory Protection:IN OUTDOOR OR OPEN AREAS USE APPROVED MECHANICAL
FILTER.
Ventilation:PROVIDE GENERAL DILUTION OR LOCAL EXHAUST VENTILATION.
Protective Gloves:REQUIRED
Eye Protection:SPLASH-PROOF EYEWEAR
Other Protective Equipment:PREVENT PROLONGED SKIN CONTACT TO
CONTAMINATED CLOTHING.
Supplemental Safety and Health
604 E. 13TH STREET ANDOVER, KANSAS 67002

Chemical Properties

HCC:F2
Boiling Pt:B.P. Text:174-329F
Vapor Density:YES
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:78.1

Stability

Stability Indicator/Materials to Avoid:YES
(MATERIALS TO AVOID)
Stability Condition to Avoid:AVOID FIRES, HEAT, AND HOT SURFACES.

Disposal

Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH LOCAL, STATE, AND
FEDERAL REGULATIONS. INCINERATE IN APPROVED FACILITY. DO NOT
INCINERATE CLOSED CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.