BDLZX - ENSOLITE TYPE LSC

  • MSDS: BDLZX
  • Manufacturer: UNIROYAL INC
  • Product Name: ENSOLITE TYPE LSC
  • National Stock Number: 5640-00-237-4781
Product Identification

Product ID:ENSOLITE TYPE LSC
MSDS Date:01/01/1985
FSC:5640
NIIN:00-237-4781
MSDS Number: BDLZX

Responsible Party
UNIROYAL, INC.

Emergency Phone: 219-255-2181

Cage: KO401

Contractor
UNIROYAL, INC.
2000 MISHAWAKA, IN 46544-1399 US

Cage: KO401

Ingredients

NO INGREDIENT FOR THIS FORMULATION_INGREDIENT

Hazards

Effects of Overexposure:ENSOLITE DOES NOT PRESENT ANY KNOWN HEALTH
HAZARD UNDER NORMAL CONTIONS OF USE. SEE ALSO SECTION IX

Fire Fighting

Extinguishing Media:WATER SPRAY, DRY CHEMICAL, CO*2
Fire Fighting Procedures:FIREFIGHTERS SHOULD USE SELF-CONTAINED
BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:COMBUSTION PROD. SHOULD BE CONSIDERED
TOXIC. TOXIC FIRE/GAS HAZARD INCL. HCL, A PULMONARY IRRITANT.

Accidental Release

Spill Release Procedures:ACCORDING TO MANUFACTURER NO SPECIAL STEPS
NECESSARY.

Handling

Handling and Storage Precautions:BEST STORED IN COOL, DRL LOCATION.
NORMALLY NO OTHER PRECAUTIONS NEEDED FOR ORDINARY HANDLING OR
STORAGE.
Other Precautions:FOR HOT PROCESSING(ABOVE 175F,79C E.G. THERMOFORMING)
LOCAL EXHAUST, SAFETY GLASSES, AND GLOVES(FOR THERMAL PROTECTION)
ARE RECOMMENDED.

Exposure Controls

Respiratory Protection:SEE SECTION IX
Ventilation:SEE SECTION IX
Protective Gloves:SEE SECTION IX
Eye Protection:SEE SECTION IX
Supplemental Safety and Health
DENSITY(POUNDS/CUBIC FOOT):4.5 TO 8.5. MANUFACTURER SPECIFIES EACH
SHEET TO MEASURE 42" X 56" AND 1/2" THICK.

Chemical Properties

HCC:N1
Solubility in Water:NIL
Appearance and Odor:CLOSED CELL PVC/NITRILE FOAM, NEGLIGIBLE ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
NONE
Hazardous Decomposition Products:THERMD3ECOMP:POS ORGANIC&INORG HALOGEN
CMPD,CO**,CYANIDE CMP

Disposal

Waste Disposal Methods:BURY IN AN APPROVED LANDFILL SITE IN ACCORDANCE
WITH APPLICABLE LOCAL, STATE, AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.