BDQDY - R-1053

Product Identification

Product ID:R-1053
MSDS Date:01/01/1987
FSC:8040
NIIN:00-262-9025
MSDS Number: BDQDY

Responsible Party
SIDMAK LABORATORIES, INC
17 WEST ST
EAST HANOVER, NJ 07936-2822
US

Emergency Phone: 201-386-5566

Info Phone: 201-386-0547

Cage: 1BL76

Contractor
SIDMAK LABORATORIES, INC
371 EAST HANOVER, NJ 07936-2822 US

Telephone: 201-386-5566

Cage: 1BL76

Ingredients

SBR RUBBER

Fraction By Weight: 11%


SOLVENTS

Fraction By Weight: 60%


ROSIN DERIVED RESINS

Fraction By Weight: 25%

ACGIH TLV: 500PPM


STABLIZERS


MODIFIED STYRENE-BUTADIENE RUBBER

Hazards

Effects of Overexposure:NARCOSSIS AND/OR POSSIBLE HEADACHE OR BRONCHIAL
CATARRAH

First Aid

First Aid:FRESH AIR-SEE DOCTOR

Fire Fighting

Flash Point:<20F TCC -7C
Lower Limits:1.2
Upper Limits:6.7
Extinguishing Media:DRY CHEMICAL,CO*2,FOAM,TRICHLORETHANE
Fire Fighting Procedures:SELF-CONTAINED BREATHING APPARATUS SHOULD BE
WORN.
Unusual Fire/Explosion Hazard:KEEP AWAY FROM OPEN FLAME,SPARKS,HOT
SURFACES AND OXIDERS.

Accidental Release

Spill Release Procedures:WIPE UP

Handling

Handling and Storage Precautions:DO NOT STORE NEAR HEAT OR IN DIRECT
SUNLIGHT.STORE IN SOLVENT STORAGE AREA.

Exposure Controls

Ventilation:LOCAL EXHAUST
Protective Gloves:YES
Eye Protection:SAFETY GLASSES
Supplemental Safety and Health

Chemical Properties

HCC:F2
Boiling Pt:B.P. Text:152F 41C
Vapor Pres:2.1
Vapor Density:0.68
Spec Gravity:0.78
Evaporation Rate & Reference:8.3
Solubility in Water:NONE
Appearance and Odor:LIGHT AMBER,CHARACTERISTIC NAPHTHA ODOR
Percent Volatiles by Volume:74

Stability

Stability Indicator/Materials to Avoid:YES
OXIDES OF CARBON METHANE

Disposal

Waste Disposal Methods:SOLVENT DISPOSAL PROCEDURES

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.