BDZYV - BOSTIK
- MSDS: BDZYV
- Manufacturer: BOSTIK WEST DIV OF USM CORP AN EMHART UNIT
- Product Name: BOSTIK
- National Stock Number: 8010-00-482-5652
Product Identification
Product ID:BOSTIK
MSDS Date:01/01/1985
FSC:8010
NIIN:00-482-5652
Kit Part:Y
MSDS Number: BDZYV
Responsible Party
ORANGE, CA 92661
US
Cage: LO442
Contractor
Telephone: 714-637-1750; CHEMTREC 800-424-9300
Cage: LO442
Ingredients
ETHYL ACETATE
RTECS: KQ4900000
Fraction By Weight: 20-2%
CELLOSOLVE ACETATE
RTECS: FJ4375000
Fraction By Weight: 20-2%
TOLUENE (SARA III)
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 15-2%
OSHA PEL 200 PPM/150 STEL
ACGIH TLV: 50 PPM; 9293
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
XYLENES (O-,M-,P- ISOMERS) (SARA III)
CAS: 1330-20-7
RTECS: ZE2100000
Fraction By Weight: 5-10%
OSHA PEL 100 PPM/150 STEL
ACGIH TLV: 100 PPM/150STEL;9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
Effects of Overexposure:HEADACHE NAUSEA,DIZZINESS,BREATHING VAPOR WILL
BE IRRITATING TO NOSE, THROAT AND EYES.
First Aid
First Aid:SKIN EXPOSURE:WASH AFFECTED AREA W/SOAP AND WATER.EYE
EXPOS:FLUSH W/WATER FOR AT LEAST 15 MINUTES,CONSULT
PHYS.INGESTION:CONSULT PHYS. IMMEDIATELY.INHALATION:REMOVE VICTIM
TO FRESH AIR,CONSULT PHYSICI AN.
Fire Fighting
Flash Point:24F TCC -4C
Lower Limits:1.0
Extinguishing Media:EXCLUDE AIR-USE FOAM,CO*2,STEAM,WATER FOG,DRY
CHEM.DO NOT
Fire Fighting Procedures:DO NOT USE WATER,EXCLUDE AIR,USE WATER SPRAY
TO COOL FIRE EX
Unusual Fire/Explosion Hazard:VAPOR FORMS EXPLOSIVE MIXTURE W/AIR
BETWEEN UPPER & LOWER EXPLOSION LIMITS.
Accidental Release
Spill Release Procedures:ELIMINATE SOURCES OF IGNITION & CLEAR FUMES
FROM AREA,PREVENT LIQUID FROM ENTERING SEWERS,WATER SOURCES,OR LOW
AREAS.KEEP UNNEC.PERSONNEL AWAY.SHUT OFF SOURCE,IF POSS TO DO SO
W/O HAZARD.CONTAIN SPILL ED LIQUID W SAWDUST OR OIL ABSORB
COMPOUND,WASH AR
Handling
Handling and Storage Precautions:MATERIAL IS SENSITIVE TO MOISTURE &
SHOULD BE KEPT IN TIGHTLY CLOSED CONTAINERS
Other Precautions:ALL HANDLING EQUIPMENT SHOULD BE ELECTRICALLY
GROUNDED.TREAT AS A VERY FLAMMABLE LIQUID.
Exposure Controls
Respiratory Protection:USE APPRVD RESPIR PROTECTION SUCH AS AN
AIR-SUPPLIED MASK IF USED IN
Ventilation:FACE VELOSITY >60 FPM IN CONFINED AREA
Protective Gloves:CHEM RESISTANT
Eye Protection:CHEM SPLASH GOGG OR FACE
Other Protective Equipment:EYE BATH & SAFETY SHOWER
Supplemental Safety and Health
RESPIR. PROTECT:USE APPRVD RESPIRATORY PROTECTION SUCH AS AN
AIR-SUPPLIED MASK IF USED IN NON-VENTILATED
AREA.MECH:EXPLOSION-PROOF VENTILATION EQUIPMENT.NO SMOKING OR OPEN
LIGHTS.
Chemical Properties
HCC:F3
Boiling Pt:B.P. Text:171-321 F
Vapor Density:HEAV
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:71
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS,INORGANIC ACIDS
Stability Condition to Avoid:STORAGE AT HIGH TEMPERATURES.SPARKS & OPEN
FLAMES
Hazardous Decomposition Products:BY FIRE, CO,CO*2 OXIDES OF
NITROGEN:AVD CONTACT W/WATER;ALCO
Disposal
Waste Disposal Methods:CONSULT DISPOSAL EXPERT & ENSURE CONFORMITY
W/LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.