BDZYV - BOSTIK

Product Identification

Product ID:BOSTIK
MSDS Date:01/01/1985
FSC:8010
NIIN:00-482-5652
Kit Part:Y
MSDS Number: BDZYV

Responsible Party
BOSTIK WEST,DIV. OF USM CORP,AN EMHART UNIT
434 W. MEAT ST.
ORANGE, CA 92661
US

Cage: LO442

Contractor
BOSTIK WEST,DIV. OF EMHART CORP
ORANGE, CA 92661 US

Telephone: 714-637-1750; CHEMTREC 800-424-9300

Cage: LO442

Ingredients

ETHYL ACETATE

RTECS: KQ4900000

Fraction By Weight: 20-2%


CELLOSOLVE ACETATE

RTECS: FJ4375000

Fraction By Weight: 20-2%


TOLUENE (SARA III)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 15-2%

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


XYLENES (O-,M-,P- ISOMERS) (SARA III)

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 5-10%

OSHA PEL 100 PPM/150 STEL

ACGIH TLV: 100 PPM/150STEL;9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

Effects of Overexposure:HEADACHE NAUSEA,DIZZINESS,BREATHING VAPOR WILL
BE IRRITATING TO NOSE, THROAT AND EYES.

First Aid

First Aid:SKIN EXPOSURE:WASH AFFECTED AREA W/SOAP AND WATER.EYE
EXPOS:FLUSH W/WATER FOR AT LEAST 15 MINUTES,CONSULT
PHYS.INGESTION:CONSULT PHYS. IMMEDIATELY.INHALATION:REMOVE VICTIM
TO FRESH AIR,CONSULT PHYSICI AN.

Fire Fighting

Flash Point:24F TCC -4C
Lower Limits:1.0
Extinguishing Media:EXCLUDE AIR-USE FOAM,CO*2,STEAM,WATER FOG,DRY
CHEM.DO NOT
Fire Fighting Procedures:DO NOT USE WATER,EXCLUDE AIR,USE WATER SPRAY
TO COOL FIRE EX
Unusual Fire/Explosion Hazard:VAPOR FORMS EXPLOSIVE MIXTURE W/AIR
BETWEEN UPPER & LOWER EXPLOSION LIMITS.

Accidental Release

Spill Release Procedures:ELIMINATE SOURCES OF IGNITION & CLEAR FUMES
FROM AREA,PREVENT LIQUID FROM ENTERING SEWERS,WATER SOURCES,OR LOW
AREAS.KEEP UNNEC.PERSONNEL AWAY.SHUT OFF SOURCE,IF POSS TO DO SO
W/O HAZARD.CONTAIN SPILL ED LIQUID W SAWDUST OR OIL ABSORB
COMPOUND,WASH AR

Handling

Handling and Storage Precautions:MATERIAL IS SENSITIVE TO MOISTURE &
SHOULD BE KEPT IN TIGHTLY CLOSED CONTAINERS
Other Precautions:ALL HANDLING EQUIPMENT SHOULD BE ELECTRICALLY
GROUNDED.TREAT AS A VERY FLAMMABLE LIQUID.

Exposure Controls

Respiratory Protection:USE APPRVD RESPIR PROTECTION SUCH AS AN
AIR-SUPPLIED MASK IF USED IN
Ventilation:FACE VELOSITY >60 FPM IN CONFINED AREA
Protective Gloves:CHEM RESISTANT
Eye Protection:CHEM SPLASH GOGG OR FACE
Other Protective Equipment:EYE BATH & SAFETY SHOWER
Supplemental Safety and Health
RESPIR. PROTECT:USE APPRVD RESPIRATORY PROTECTION SUCH AS AN
AIR-SUPPLIED MASK IF USED IN NON-VENTILATED
AREA.MECH:EXPLOSION-PROOF VENTILATION EQUIPMENT.NO SMOKING OR OPEN
LIGHTS.

Chemical Properties

HCC:F3
Boiling Pt:B.P. Text:171-321 F
Vapor Density:HEAV
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:71

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS,INORGANIC ACIDS
Stability Condition to Avoid:STORAGE AT HIGH TEMPERATURES.SPARKS & OPEN
FLAMES
Hazardous Decomposition Products:BY FIRE, CO,CO*2 OXIDES OF
NITROGEN:AVD CONTACT W/WATER;ALCO

Disposal

Waste Disposal Methods:CONSULT DISPOSAL EXPERT & ENSURE CONFORMITY
W/LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their