BFRPK - M-PHENYLENEDIAMINE,TECHNICAL
- MSDS: BFRPK
- Manufacturer: FISHER SCIENTIFIC COMPANY (CHEMICAL COMMODITIES)
- Product Name: M-PHENYLENEDIAMINE,TECHNICAL
- National Stock Number: 6810-00-829-7066
Product Identification
Product ID:M-PHENYLENEDIAMINE,TECHNICAL
MSDS Date:01/01/1985
FSC:6810
NIIN:00-829-7066
MSDS Number: BFRPK
Responsible Party
FAIR LAWN, NJ 07410-2802
US
Cage: 2G230
Contractor
Telephone: 201-796-7100/800-766-7000 X3725
Cage: 2G230
Ingredients
M-PHENYLENEDIAMINE
Fraction By Weight: 99.3%
ACGIH TLV: 0.1MG/CUM(PARA)
Hazards
Effects of Overexposure:HARMFUL IF SWALLOWED.CAUSES IRRITATION.
First Aid
First Aid:INGESTION:INDUCE VOMITING.CONTACT A PHYSICIAN.SKIN &
EYES:FLUSH WITH PLENTY OF WATER FOR AT LEAST 15 MIN.REMOVE
CONTAMINATED CLOTHES & SEND TO DOCTOR.INHALATION:FRESH
AIR,REST,HALF UPRIGHT POSITION,& TRANSPORT TO HOSPITAL.
Fire Fighting
Extinguishing Media:CO*2,DRY CHEMICAL
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS
Unusual Fire/Explosion Hazard:WHEN HEATED TO DECOMPOSITION EMITS TOXIC
FUMES OF NOX.
Accidental Release
Spill Release Procedures:SCOOP UP & PLACE IN A SUITABLE CONTAINER OR
ABSORB W/SAND,EARTH,OTHER ABSORB MATL.SWEEP AREA TO CLEAN ANY
RESIDUAL MATERIAL.LG SPILL:DIKE FOR DECONTAMINATION &
DISPOSAL.COVER POWDERED SPILLS.CLEAN UP UNDER SUPERVISION OF
EXPERT.
Handling
Handling and Storage Precautions:STORE IN COOL,DRY,WELL VENTILATED
AREA.PROTECT FROM PHYSICAL DAMAGE.AVOID ANY PHYSICAL CONTACT.KEEP
CONTAINERS TIGHTLY CLOSED.
Other Precautions:SEPARATE FROM OXIDUNTS,IN THE DARK.REMOVE
CONTAMINATED CLOTHES,RINSE SKIN WITH PLENTY OF WATER OR SHOWER.USE
GOOD INDUSTRIAL HYGIENE PRACTICES.
Exposure Controls
Respiratory Protection:DUST MASK
Ventilation:LOCAL EXHAUST & MECHANICAL IS ACCEPTABLE.
Protective Gloves:RUBBER
Eye Protection:SAFETY GLASSES.
Supplemental Safety and Health
Chemical Properties
HCC:T4
Boiling Pt:B.P. Text:494.6F(257C
Spec Gravity:UNK
Solubility in Water:SLIGHT
Appearance and Odor:LIGHT-TAN,SMALL FLAKES
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS
Hazardous Decomposition Products:WHEN HEATED TO DECOMPOSITION,EMITS
TOXIC FUMES OF NO*X
Disposal
Waste Disposal Methods:MFR SUGGESTS DISPOSE OF BY MEANS AS TO COMPANY
WITH ALL LOCAL,STATE & FEDERAL REGULATIONS OR CONTACT AN APPROVED
AND LICENSED DISPOSAL AGENCY.KEEP IN COVERED DRUMS,PENDING
DISPOSAL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.