BFVFD - BLT-059

Product Identification

Product ID:BLT-059
MSDS Date:04/19/1994
FSC:5960
NIIN:00-894-7128
MSDS Number: BFVFD

Responsible Party
VARIAN ASSOCIATES,BEVERLY DIV
150 SOHIER RD.
BEVERLY, MA 01915-5595
US

Emergency Phone: 508-922-6000

Info Phone: 508-922-6000

Preparer: FRANK TROJAN

Cage: 88236

Contractor
COMMUNICATIONS AND POWER INDUSTRIES INC
BEVERLY, MA 01915-5595 US

Telephone: 978-922-6000 EXT.285

Cage: 88236

Ingredients

COBALT (SARA III)

CAS: 7440-48-4

RTECS: GF8750000

OSHA PEL 0.1 MG/M3;AS CO

ACGIH TLV: 0.05 MG/M3;DUST 9293

Hazards

LD50 LC50 Mixture:ORAL LD50 (RAT) IS 6170 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:THIS ITEM EMITS BETA AND GAMMA
RADIATION.SKIN:MAY CAUSE BURNS.EYES:MAY CAUSE BURNS.INHAL:MAY BE
HARMFUL.INGEST:MAY BE HARMFUL IF SWALLOWED.
Explanation of Carcinogenicity:COBALT 60 IS A GAMMA AND BETA
EMITTER.THIS RADIATION MAY CAUSE CANCER.
Effects of Overexposure:INGEST/INHAL:HIGH DOSES MAY CAUSE
NAUSEA,VOMITING AND DIARRHEA,DIFFICULT
BREATHING,WHEEZING,ASTMA-LIKE SYMPTOMS,SWOLLEN GLANDS IN THE
CREASES OF ELBOWS,KNEES,ANKLES,NECK.SKIN:DERMATITIS.EYES:CONJUNTIV
ITIS.
Medical Cond Aggravated by Exposure:PERSONS WITH PRE-EXISTING SKIN AND
RESPIRATORY AILMENTS MAY BE AT INCREASED RISK FROM EXPOSURE.HEALING
OF EXISTING WOUNDS MAY BE PROLONGED.

First Aid

First Aid:DECOMTAMINATE THE EXPOSED INDIVIDUAL.TRANSPORT TO THE HOSPIAL
IF NAUSEA AND VOMITNG OCCUR WITHIN THE FIRST 24 HOURS.EYES:FLUSH
WITH WATER.SKIN:WASH WITH SOAP AND WATER.INHAL:REMOVE TO FRESH
AIR.SUPPOR T BREATHING IF NEEDED.INGEST:IF CONSCIOUS,GIVE WATER AND
INDUCE VOMITING.

Fire Fighting

Flash Point:NONE
Extinguishing Media:EXTINQUISH W. AGENT SUITABLE FOR SURROUNDING FIRE.
Fire Fighting Procedures:USE A SELF-CONTAINED BREATHING APPARATUS AND
FULL PROTECTIVE EQUIPMENT.
Unusual Fire/Explosion Hazard:FIRE CONDITIONS MAY CAUSE RELEASE OF
RADIOACTIVE MATERIAL.

Accidental Release

Spill Release Procedures:HANDLE BROKEN DEVICE WITH GLOVES AND FORCEPS.
Neutralizing Agent:NONE

Handling

Handling and Storage Precautions:SHIELD ACCORDING TO EMITTED RADIATION.
PROTECT FILM AND FILM PLATES. KEEP CONTAINERS CLOSED. STORE IN AREA
FOR RADIOACTIVE MATERIALS.
Other Precautions:FOLLOW LABEL DIRECTIONS.AVOID PHYSICAL DAMAGE.

Exposure Controls

Respiratory Protection:WHERE ENVIRONMENTAL CONTROLS ARE LACKING OR IN
ENCLOSED SPACES USE A SELF-CONTAINED BREATHING APPARATUS.
Ventilation:NOT NESCESSARY IN NORMAL SERVICE.FOR EMERGENCY
CONDITIONS,CONTACT YOUR RADIATION SAFETY MANAGER.
Protective Gloves:NOT NEEDED IN NORMAL SERVICE.
Eye Protection:NOT NEEDED IN NORMAL SERVICE.
Other Protective Equipment:NONE
Work Hygienic Practices:USE REASONABLE CARE IN HANDLING THIS MATERIAL.
Supplemental Safety and Health
NONE

Chemical Properties

HCC:A2
Boiling Pt:B.P. Text:5252F,2900C
Melt/Freeze Pt:M.P/F.P Text:2723F,1495C
Vapor Pres:10E-9
Spec Gravity:8.9
Solubility in Water:NEGLIGIBLE
Appearance and Odor:SOLID;SILVER;NO ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
MANUFACTURER STATES NONE.
Stability Condition to Avoid:PHYSICAL DAMAGE.
Hazardous Decomposition Products:DEPENDS ON CHEMICAL COMPOSITION;
FISSION PRODUCTS

Disposal

Waste Disposal Methods:CONTACT YOUR RADIATION SAFETY MANAGER.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.