BFWYM - IRIDITE 14-2

Product Identification

Product ID:IRIDITE 14-2
MSDS Date:01/01/1985
FSC:8030
NIIN:00-926-9131
MSDS Number: BFWYM

Responsible Party
ALLIED-KELITE PROD, DIV OF THE RICHARDSON CO
400 MIDLAND AVE
HIGHLAND PARK, MI 48203-3734
US

Cage: 8G948

Contractor
WITCO ALLIED-KELITE DIV OF WITCO CHEMICAL CORP
HIGHLAND PARK, MI 48203-3734 US

Telephone: 313-437-8161/800-424-9300(CHEMTREC)

Cage: 99442

Ingredients

FLUORIDE

Fraction By Weight: <9.0%

ACGIH TLV: 2.5MG/CUM


CHROMIUM ION (CR 6+)

CAS: 18540-29-9

RTECS: GB6262000

Fraction By Weight: <30%

OSHA PEL C, 0.1 MG/M3 (CRO3)

ACGIH TLV: 0.05 MG/M3 (CR);8990


FERRICYANIDE SALTS

Fraction By Weight: <10%

Hazards

Effects of Overexposure:CHROMIC CNTCT MAY CAUSE SKIN ULCERS & ATTACK
MUCOUS MEMBRANES

First Aid

First Aid:EYE: IMMED FLUSH W/WATER 15 MIN, SEE MD. SKIN: THOROUGHLY
WASH W/SOAP & WATER.

Fire Fighting

Extinguishing Media:WATER OR FOAM
Fire Fighting Procedures:AVOID CNTCT W/ORGANIC MATLS
Unusual Fire/Explosion Hazard:CNTCT W/ALCOHOLS & SOME ORGANICS MAY
CAUSE SPONTANEOUS IGNITION

Accidental Release

Spill Release Procedures:AVOID INH DUST. POWDER CAN ATTACK MUCOUS
MEMBRANES. WASH AREA W/WATER.

Handling

Handling and Storage Precautions:ISOLATE FROM REACTIVE MATLS. STORE
AWAY FROM DIRECT HEAT. TREAT IRIDITE 14-2 AS ANY CHROMIC ACID CMPD.
KEEP FROM ORGANIC & REDUCING AGENT.
Other Precautions:KEEP DRY. ACID SOLUTION: WHEN DISSOLVED IN WATER,
WILL CORRODE IRON, ALUMINUM, ZINC, COPPER. USE STAINLESS STEEL OR
PVC LINED TANKS. DOT: OXIDIZER.

Exposure Controls

Respiratory Protection:MFR REC DUST MASK. USE NIOSH/MSHA APPRVD DEVICE.
Ventilation:MFR REC LOCAL EXHST
Protective Gloves:RUBBER
Eye Protection:FACE SHLD
Other Protective Equipment:RUBBER APRON/BOOTS
Supplemental Safety and Health
EMERGENCY TEL, NITE: 313-644-5626

Chemical Properties

HCC:D4
Boiling Pt:B.P. Text:DRY CMPD
Solubility in Water:APPROX 99
Appearance and Odor:REDDISH-BROWN POWDER, BROWN SOLUTION, NO ODOR

Stability

Stability Indicator/Materials to Avoid:YES
ORGANIC MATLS & ANY REDUCING AGENTS
Stability Condition to Avoid:AVOID HEATING POWDER >150F. AVOID HEATING
SOLUTION >140F.
Hazardous Decomposition Products:INFIRE OR ABNRML TEMP, TOXIC FUMES MAY
BE PRODUCED

Disposal

Waste Disposal Methods:CHECK LOCAL ORDINANCES FOR HEXAVALENT CHROMIUM
CONTAM IN EFFLUENT. IF NECESSARY, TREAT AS FOR CHROMIC ACID. FOLLOW
FED, STATE, LOCAL CODES REGARDING DISPOSAL.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.