BGCJK - AWS #347

Product Identification

Product ID:AWS #347
MSDS Date:09/01/1989
FSC:3439
NIIN:00-995-9721
MSDS Number: BGCJK

Responsible Party
TECHALLOY MARYLAND INC., REID-AVERY DIV.
2310 CHESAPEAKE AVE.
BALTIMORE, MD 21222-4012
US

Emergency Phone: 301-633-9300

Info Phone: 800-638-1458

Cage: 59711

Contractor
TECHALLOY COMPANY, INC.
BALTIMORE, MD 21222 US

Telephone: 410-633-9300; 800-638-1458

Cage: 59711

Ingredients

IRON

CAS: 7439-89-6

RTECS: NO4565500

Fraction By Weight: 45-80%

OSHA PEL 10 MG/CUM

ACGIH TLV: 10 MG/CUM


CHROMIUM (SARA III)

CAS: 7440-47-3

RTECS: GB4200000

Fraction By Weight: 11-32%

OSHA PEL 1 MG/M3

ACGIH TLV: 0.5 MG/M3; 9192

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


NICKEL (SARA III)

CAS: 7440-02-0

RTECS: QR5950000

Fraction By Weight: 4-37%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3; 9192


MANGANESE (SARA III)

CAS: 7439-96-5

RTECS: OO9275000

Fraction By Weight: 0.5-2.5%

OSHA PEL (C) 5 MG/M3 DUST

ACGIH TLV: 5 MG/M3 DUST 9293


SILICON

CAS: 7440-21-3

RTECS: VW0400000

Fraction By Weight: 0.1-1.0%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


MOLYBDENUM

CAS: 7439-98-7

RTECS: QA4680000

Fraction By Weight: <4.0%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3; 9293

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:MAY RESULT IN DISCOMFORT SUCH AS
DIZZINESS,NAUSEA,DRYNESS OR IRRITATION OF NOSE,THROAT OR
EYES,TIGHTNESS IN CHEST,FEVER & ALLERGIC REACTIONS. CHRONIC:MAY
LEAD TO SIDEROSIS & IS BELIEVED BY SOME INVESTIGATORS TO AFFECT
PULMONARY FUNCTION.
Explanation of Carcinogenicity:NICKEL & CHROMIUM ARE LISTED AS
CARCINOGENIC.
Effects of Overexposure:SEE "HEALTH HAZARDS".
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:REMOVE TO FRESH AIR,IF BREATHING IS DIFFICULT,ADMINISTER
OXYGEN,IF BREATHING HAS STOPPED,APPLY ARTIFICIAL RESPIRATOR; GET
MEDICAL HELP.

Fire Fighting

Extinguishing Media:MEDIA APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:WELDING ARC & SPARKS CAN IGNITE
COMBUSTIBLES. REFER TO AMERICAN NATIONAL STANDARD Z49.1 FOR FIRE
PREVENTION DURING THE USE OF WELDING AND ALLIED PROCEDURES.

Accidental Release

Spill Release Procedures:SWEEP UP OR SCOOP UP AND PLACE IN A CONTAINER
FOR LATER DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:USE EXHAUST SYSTEM TO CLEAR WELDING
FUMES.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:USE RESPIRABLE FUME RESPIRATOR OR AIR SUPPLIED
RESPIRATOR WHEN WELDING IN A CONFINED SPACE OR WHERE LOCAL EXHAUST
OR VENTILATION DOES NOT KEEP EXPOSURE BELOW TLV.
Ventilation:USE ADEQUATE GENERAL VENTILATION & LOCAL EXHAUST AT THE
ARC.
Protective Gloves:WELDER'S GLOVES.
Eye Protection:HELMET/FACE SHIELD WITH FILTER LENS.
Other Protective Equipment:WEAR PROTECTIVE CLOTHING.
Work Hygienic Practices:WASH HANDS AFTER USE AND BEFORE EATING,
DRINKING, OR SMOKING.
Supplemental Safety and Health
MIL-347 ALSO APPLIES.

Chemical Properties

HCC:N1
Solubility in Water:INSOLUBLE
Appearance and Odor:SOLID WIRE OR ROD.
Percent Volatiles by Volume:0

Stability

Stability Indicator/Materials to Avoid:YES
NONE
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:IT IS COMPLEX & CAN NOT BE CLASSIFIED
EASILY,DEPENDING ON THE ELECTRODE USED,COATING & CONTAMINANTS IN
THE ATMOSPHERE.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.