BGRLK - FUSER AGENT: XEROX FA-1
- MSDS: BGRLK
- Manufacturer: NASHUA CORP OFFICE PRODUCTS DIV
- Product Name: FUSER AGENT: XEROX FA-1
- National Stock Number: 6850-01-259-7154
Product Identification
Product ID:FUSER AGENT: XEROX FA-1
MSDS Date:10/29/1991
FSC:6850
NIIN:01-259-7154
MSDS Number: BGRLK
Responsible Party
NASHUA, NH 03061
US
Emergency Phone: 603-880-5555
Info Phone: 603-880-5555
Preparer: R. L. SEVIGNY
Cage: 34936
Contractor
Telephone: 603-880-2323
Cage: 34936
Ingredients
MERCAPTO-FUNCTIONAL POLYDIMETHYLSILOXANE
CAS: 63148-62-9
RTECS: JT6484500
Fraction By Weight: 100%
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NO KNOWN CHRONIC OR ACUTE HEALTH
HAZARDS WHEN USED AS INTENDED.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO INGREDIENTS AT
CONCENTRATIONS OF 0.1% OR GREATER THAT ARE CARCINOGENS OR SUSPECT
CARCINOGENS.
Effects of Overexposure:MAY CAUSE TEMPORARY DISCOMFORT TO EYES. HAS
LAXATIVE EFFECT UPON INGESTION.
Medical Cond Aggravated by Exposure:NONE KNOWN.
First Aid
First Aid:INHALATION: REMOVE FROM EXPOSURE. SKIN: WIPE OFF AND WASH
SKIN WITH SOAP AND WATER. EYES: FLUSH EYES FOR AT LEAST 15 MINUTES
WITH LARGE AMOUNTS OF WATER. INGESTION: DRINK WATER IF INGESTED AND
CALL PO ISON CONTROL CENTER.
Fire Fighting
Flash Point Method:COC
Flash Point:600F,316C
Extinguishing Media:WATER FOG, CO2, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
Accidental Release
Spill Release Procedures:USE ABSORBENT MATERIAL TO COLLECT AND CONTROL
SPILLAGE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:AVOID RUBBING EYES WITH HANDS WHILE
USING MATERIAL.
Other Precautions:CLEAN UP SPILLS COMPLETELY AS RESIDUE IS SLIPPERY.
UPON EYE CONTACT REMOVE AND CLEAN CONTACT LENSES PRIOR TO REUSE.
Exposure Controls
Respiratory Protection:IF VENTILATION DOES NOT MAINTAIN INHALATION
EXOSURES BELOW PEL (TLV), USE NIOSH/MSHA APPROVED RESPIRATOR AS PER
CURRENT 29 CFR 1910.134, INSTRUCTIONS/WARNINGS AND NIOSH RESPIRATOR
SELECTION.
Ventilation:LOCAL EXHAUST AND MECHANICAL (GENERAL) VENTILATION TO
MAINTAIN EXPOSURE LEVELS.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES.
Other Protective Equipment:NONE REQUIRED.
Work Hygienic Practices:WASH WITH SOAP AND WATER AFTER HANDLING PRODUCT
AND BEFORE EATING DRINKING OR SMOKING.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:>600F,>316C
Vapor Pres:<5
Spec Gravity:0.98 (H2O=1)
Evaporation Rate & Reference:<1 (BUTYL ACETATE=1)
Solubility in Water:<0.1%
Appearance and Odor:CLEAR COLORLESS LIQUID, VERY LITTLE ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
OXIDIZING MATERIAL CAN CAUSE REACTION.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:SILICON DIOXIDE, CARBON DIOXIDE,
CRABON MONOXIDE, HYDROGEN SULFIDE.
Disposal
Waste Disposal Methods:DISPOSE OF LIQUID AND ABSORBENT MATERIAL
ACCORDING TO LOCAL, STATE AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.