BHCVY - FREON TMS SOLVENT

Product Identification

Product ID:FREON TMS SOLVENT
MSDS Date:01/01/1987
FSC:6810
NIIN:01-120-6694
MSDS Number: BHCVY

Responsible Party
E. I. DUPONT DE NEMOURS AND COMPANY
FREON PRODUCTS DIVISION
WILMINGTON, DE 19898

Emergency Phone: 302-774-2421

Info Phone: 302-774-2421

Cage: 73925

Contractor
DU PONT E I DE NEMOURS AND CO INC PETROCHEMICALS DEPT
WILMINGTON, DE 19898

Telephone: 302-773-5676

Cage: 73925

Ingredients

1,1,2-TRICHLORO-1,2,2-TRIFLUOROETHANE (FREON 113) (SARA

CAS: 76-13-1

RTECS: KJ4000000

Fraction By Weight: >90%

OSHA PEL 1000PPM/1250STEL

ACGIH TLV: 1000PPM/1250STEL9192


METHYL ALCOHOL (METHANOL) (SARA III)

CAS: 67-56-1

RTECS: PC1400000

Fraction By Weight: 5.5%

OSHA PEL S,200PPM/250STEL

ACGIH TLV: S,200PPM/250STEL; 93

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:POSSIBLE CARDIAC ARRHYTHMIAS AT HIGH
CONCENTRATIONS.
Effects of Overexposure:LIGHT-HEADEDNESS, GIDDINESS, SHORTNESS OF
BREATH, POSSIBLE CARDIAC ARRHYTHMIAS AT HIGH CONCENTRATIONS.

First Aid

First Aid:INHALE: REMOVE TO FRDSH AIR, CALL A PHYSICIAN. DO NOT GIVE
EPINEPHRINE OR SIMILAR DRUGS. SKIN OR EYE CONTACT: FLUSH WITH
WATER.

Fire Fighting

Flash Point:NONE
Extinguishing Media:MATERIAL IS NON-FLAMMABLE
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER
SPRAY TO COOL NEARBY CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:ADDITION OF EXCESS WATER (>0.2%) WILL
ECTRACT ALCOHOL AND MAY FORM A FLAMMABLE SUPERNATANT LIQUID LAYER

Accidental Release

Spill Release Procedures:VENTILATE AREA, ESPECIALLY LOW PLACES WHERE
HEAVY VAPORS MIGHT COLLECT. REMOVE OPEN FLAMES.

Handling

Handling and Storage Precautions:STORE CONTAINERS IN A CLEAN, DRY AREA.
DO NOT STORE ABOVE 125F.
Other Precautions:FOR FURTHER INFORMATION SEE FREON PRODUCTS BULLETIN
S-30.

Exposure Controls

Respiratory Protection:USE AIR MASK IN HIGH CONCENTRATIONS.
Ventilation:LOCAL EXHAUST WHEN LARGE AMOUNTS ARE RELEASED. MECHANICAL
EXHAUST ESPECIALLY IN LOW PLACES.
Protective Gloves:WHEN HANDLING LIQUID
Eye Protection:WHEN HANDLING LIQUID
Work Hygienic Practices:WASH AFTER HANDLING
Supplemental Safety and Health

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:103F,40C
Vapor Pres:273
Vapor Density:2.8
Spec Gravity:1.52
Solubility in Water:<0.5
Appearance and Odor:COLORLESS LIQUID, FAINT SOLVENT ODOR
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
ALKALI OR ALKALINE EARTH METALS, POWDERED AL, ZN, BE, ETC.
Stability Condition to Avoid:HIGH TEMPERATURES, SPARKS, AND OPEN FLAMES
Hazardous Decomposition Products:HYDROCHLORIC AND HYDROFLOURIC ACIDS,
POSSIBLE CARBONYL HALIDE.

Disposal

Waste Disposal Methods:RECLAIM BY DISTILLATION

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.