Product Identification
Product ID:PRIMER COAT, SYNTHETIC, RUST INHIB. LACQ RE
MSDS Date:10/25/1983
FSC:8010
NIIN:00-292-1127
MSDS Number: BHDKD
Responsible Party
EDISON, NJ 08818-0847
US
Emergency Phone: 908-287-4000
Info Phone: 908-287-4000 / FAX 908-287-9288
Cage: 60189
Contractor
Telephone: 732-287-4000
Cage: 60189
Ingredients
ZINC CHROMATE
CAS: 13530-65-9
RTECS: GB3290000
Fraction By Weight: 4.2%
OSHA PEL 0.1 MG/M3 (CRO3)
ACGIH TLV: 0.01MG/M3(CR)A1;9192
VM&P NAPHTHA
CAS: 8032-32-4
RTECS: OI6180000
Fraction By Weight: 28.1%
ACGIH TLV: 500 PPM
N-BUTYL ALCOHOL (SARA III)
CAS: 71-36-3
RTECS: EO1400000
Fraction By Weight: 9.8%
OSHA PEL 100 PPM
ACGIH TLV: S, C 50 PPM; 9293
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Effects of Overexposure:IRRITATIN OF EYES AND SKIN MAY OCCUR WITH
OVEREXPOSURE. CONTINUED BREATHING OF VAPORS IN SOME INSTANCES, MAY
IRRITATE RESPIRATORY TRACT & CAUSE HEADACHE OR DIZZINESS, WHICH
IS NORMAL FOR SOLVENT B ASE PRODUCTS
First Aid
First Aid:FLUSH SKIN AND EYE CONTACT WITH PLENTY OF WTR. IF INHALED,
REMOVE TO FRESH AIR. IF IRRITATION PERSISTS, CONSULT A PHYSICIAN.
Fire Fighting
Flash Point Method:TCC
Flash Point:50 F 10 C
Extinguishing Media:FOAM, CO2, DRY CHEMICAL, WATER MIST
Fire Fighting Procedures:SMOTHER FLAMES WITH ONE OF THE ABOVE
EXTINGUISHING MEDIA. WATER MAY BE USED TO COOL DOWN UNOPENED
CONTAINERS IN VICINITY
Unusual Fire/Explosion Hazard:CONTAINS FLAMMABLE SOLVENT. DO NOT USE IN
AREAS WHERE SPARKS OR OPEN FLAMES ARE PRESENT
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. AVOID
PROLONGED BREATHING OF VAPORS. VENTILATE AREA. CLEAN UP
WITHABSORBENT MATERIAL
Handling
Handling and Storage Precautions:STORE IN BUILDINGS DESIGNED AND
PROTECTED FOR STORAGE OF NFPA CLASS II FLAMMABLE LIQUIDS
Other Precautions:STORE IN BUILDINGS DESIGNED AND PROTECTED FOR STORAGE
OF NFPA CLASS II FLAMMABLE LIQUIDS
Exposure Controls
Respiratory Protection:OUTDOOR OR OPEN AREAS, USE NIOSH APPROVED FILTER
RESPIRATOR TO REMOVE SOLID AIR-BORNE PARTICLES. IN RESTRICTED
VENTILATION AREAS, USE NIOSH APPROVED CHEMICAL FILTERS TO REMOVE
COMBINATION OF VAPORS
Ventilation:PROVIDE GENERAL DILUTION OR LOCAL EXHAUST VENTILATION IN
VOLUME AND PATTERN BELOW ACCEPTABLE LIMIT
Protective Gloves:REQUIRED FOR LG OR REPEATED EXPOSURE
Eye Protection:TO PROTECT AGAINST SPLASH OF LIQUIDS
Other Protective Equipment:PREVENT PROLONGED SKIN CONTACT WITH
CONTAMINATED CLOTHING
Supplemental Safety and Health
NK
Chemical Properties
HCC:F3
Boiling Pt:B.P. Text:243-245 F
Vapor Density:> AIR
Evaporation Rate & Reference:SLOWER THAN ETHR
Percent Volatiles by Volume:64.6
Stability
Stability Indicator/Materials to Avoid:YES
NK
Hazardous Decomposition Products:CO, CO2
Disposal
Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH LOCAL, STATE &
FEDERALREGULATIONS. DO NOT INCINERATE UNOPENED CONTAINERS
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.