BHDQK - ENAMEL ALKYD GLOSS BLUE 15044 ID742504

  • MSDS: BHDQK
  • Manufacturer: PRATT AND LAMBERT INC
  • Product Name: ENAMEL ALKYD GLOSS BLUE 15044 ID742504
  • National Stock Number: 8010-00-598-5927
Product Identification

Product ID:ENAMEL ALKYD GLOSS BLUE 15044 ID742504
MSDS Date:03/23/1988
FSC:8010
NIIN:00-598-5927
MSDS Number: BHDQK

Responsible Party
PRATT & LAMBERT, INC.
WICHITA, KS 67201
US

Emergency Phone: 316-733-1361

Info Phone: 316-733-1361

Preparer: W.A. ELLISON

Cage: FO127

Contractor
PRATT AND LAMBERT INC
22 CLEVELAND, OH 44101-1027 US

Telephone: 216-566-2902

Cage: 61196

Ingredients

NO INGREDIENT FOR THIS FORMULATION_INGREDIENT

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Health Hazards Acute and Chronic:SWALLOWING: GASTROINTESTINAL
IRRITATION, NAUSEA, AND VOMITING. ASPIRATION OF MA TERIAL INTO LUNG
MAY CAUSE CHEMICAL PNEUMONITIS. INHALATION NOSE OR THROAT
IRRITATION. EYE: MAY CAUSE EYE IRRITATION. SK IN: MAY CAUSE
DEFATTING AND IRRITATIONOF THE SKIN.
Effects of Overexposure:REPORTS HAVE ASSOCIATED PROLONGED AND REPEATED
OCCUPATIONAL OVEREXPOSURE TO SOLVENTS WITH PERMANENT BRAIN AND
NERVOUS SYSTEM DAMAGE. INTENTIONAL MISUSE BY DELIBERATELY
CONCENTRATING AND INHALING THE C ONTENTS MAY BE HARMFUL OR FATAL.

First Aid

First Aid:SWALLOWING: DO NOT INDUCE VOMITING. GET MED ATTN. INHALATION:
REMOVE TO FRESH AIR IMMED. IF BREATHING HAS STOPPED GIVE CPR. GET
MED ATTN. SKIN: REMOVE CONTAMINATED CLOTHING. WASH AFFECTED AREA
W/SOA P AND WATER. OBTAIN MED ATTN IF IRRITATION PERSISTS. NOTE TO
PHYSICIAN- ANY TREATMENT SHOULD BE DIRECTED AT THE CONTROL OF
SYMPTOMS AND THE CLINICAL CONDITIONS. EYE: FLUSH WITH LARGE AMOUNTS
OF WATER.

Fire Fighting

Flash Point Method:SCC
Flash Point:>102F/38.89C
Extinguishing Media:CLASS B FIRE EXTINGUISHERS TO EXTINGUISH FLAMMABLE
LIQUID FIRES. POLYMER FOAM IS PREFERRED FOR LARGE FIRES.
Fire Fighting Procedures:WEAR SELF CONTAINED BREATHING APPARATUS. USE
WATER TO COOL EXPOSED CONTAINERS TOPREVENT PRESSURE BUILD-UP AND
POSSIBLE EXPLOSION. FOG NOZZLE PREFERRED W/WATER.
Unusual Fire/Explosion Hazard:KEEP CONTAINERS TIGHTLY CLOSED ISOLATE
FROM HEAT CLOSED CONTAINERS MAY EXPLODE WHEN EXPOSED TO EXTREME
HEAT.

Accidental Release

Spill Release Procedures:ELIMINATE ALL IGNITION SOURCES. DIKE AND
CONTAIN SPILL W/INERT MATERIAL. TRANSFER IN METAL CONTAINERS FOR
RECOVERY OR DISPOSAL. USE ONLY NON-SPARKING TOOLS. PREVENT
CONTAMINATION OF SEWERS, STREAMS, G ROUNDWATER WITH SPILLED
MATERIAL OR USED ABSORBENT

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 95F. STORE LARGE
QUANTITIES IN COMPLIABNCE WITH OSHA 29CFR1910.106. RCRA
CLASSIFICATION D001.
Other Precautions:DO NOT RE USE FOR ANY PURPOSE. CONTAINERS S/B
GROUNDED AND BONDED TO THE RECEIVING CONTAINER. DO NOT
WELD/BRAZE/CUT CONTAINER. NEVER USE PRESSURE TO EMPTY. CLOSE
CONTAINER AFTER EACH USE. DO NOT TAKE INTERNALLY.

Exposure Controls

Respiratory Protection:SEE OSHA 29CFR1910.1025 RESPIRATORY PROTECTION
FOR LEAD. IN RESTRICTED AREAS A NIOSH APPROVED CHEM CARTRIDGE
RESPIRATOR MAY BE REQUIRED. IN CONFINED AREAS USE ANIOSH/MSHA AIR
SUPPLIED RESPIRATOR. MECH ANICAL PREFILTER MAY BE REQ IF SPRAYING.
Ventilation:PROVIDE GENERAL DILUTION AND LOCAL EXHAUST IN SUFFICIENT
VOLUME AND PATTERN TO KEEP CONCT OF HAZARDS ING. BELOW EXP LIM
Protective Gloves:SOLVENT IMPERMEABLE GLOVES
Eye Protection:WEAR SAFETY SPECTACLES
Other Protective Equipment:NOT LIKELY TO BE NEEDED.
Supplemental Safety and Health
NK

Chemical Properties

Boiling Pt:B.P. Text:280F / 388F
Vapor Density:>AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:60

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS OR ALKALINE MATERIALS
Stability Condition to Avoid:AVOID EXCESSIVE HEAT AND SOURCES OF
IGNITION.
Hazardous Decomposition Products:BURNING,INCLUDING WHEN HEATED BY
WELDING OR CUTTING, WILL PRODUCE SMOKE, CARBON MONOXIDE AND CARBON
DIOXIDE.
Conditions to Avoid Polymerization:KEEP AWAY FROM HEAT SPARKS AND
FLAME.

Disposal

Waste Disposal Methods:DISPOSE IAW FEDERAL, STATE AND LOCAL LAWS.
INCINERATE ONLY IN EPA FACILITY. DO NOT INCINERATE
CLOSEDCONTAINERS. OBSERVE PRECAUTION FOR DISPOSAL OF FLAMMABLE
MATERIALS. CONTAMINATED ABSORBANT DISPOS E IN A HAZARDOUS WASTE
LANDFILL.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.