BHDRN - NITROGEN

Product Identification

Product ID:NITROGEN
MSDS Date:08/01/1985
FSC:6830
NIIN:00-616-9183
MSDS Number: BHDRN

Responsible Party
HAMPTON ROADS WELDERS SUPPLY CO.
3450 VIRGINIA BEACH BLVD.
NORFOLK, VA 23502
US

Emergency Phone: 514-645-5311

Info Phone: CONTACT YOUR LOCAL SUPPLIER

Cage: 70711

Contractor
HAMPTON ROADS WELDERS SUPPLY CO
12567 NORFOLK, VA 23502-3123 US

Cage: 70711

Ingredients

NITROGEN

CAS: 7727-37-9

RTECS: QW9700000

Fraction By Weight: 100%

ACGIH TLV: ASPHYXIANT; 9192

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Health Hazards Acute and Chronic:ACUTE:SKN: NO EVIDENCE OF ADVRS/HARMFL
EFFECTS FROM VAPORS. LIQ MAY CAUSE FRSTBTEYE: NO HARMFUL EFFECT.
INGST:PROD IS A GAS AT NRML TEMP & PRESS. INHL:MOD.CONCTMAY
HDACHES,DROWINS,DIZZINS,EXCITATION,E XCESS SALIVATION,VOMITING.
ASPHYXIANT.CHRONIC: NO EVIDENCE OF ADVRS EFFECTS FROM AVAIL. INFO.
Effects of Overexposure:CONTACT WITH LIQUID MAY CAUSE FROSTBITE.
Medical Cond Aggravated by Exposure:THE TOXICOLOGY/PHYSICAL/CHEMICAL
PROPERTIES OF THEMATERIAL DONOT SUGGEST THAT OVREXPOSURE IS LIKELY
TO AGGRAVATE EXISTING MEDICAL CONDITIONS.

First Aid

First Aid:SKIN: EXPOSURE TO LIQ. IMMEDIATELY WARM FRSTBITE AREA W/WRM
WTR (NOT OVER 105F) IN CASE OF MASSIVE EXPSR REMOVE CLOTHING
W/SHOWERING W/WRM WTR. CALL A PHYSICIANEYE: IN CASE OF SPLASH
CONTAMINATION, IM MEDIATELY. FLUSH EYE W/WTR FOR 15MINS.INHL:
REMOVE TO FRESH AIR. GIVE ARTIFICIAL RESP. IF NOT BREATHING. GIVE
OXYGEN IF BREATHING IS DIFFICULT. GET MEDICAL ATTENT. INGST:PROD
IS GAS AT NRML TEMP.

Fire Fighting

Flash Point:NA
Lower Limits:NA
Upper Limits:NA
Extinguishing Media:NITROGEN CANNOT CATCH FIRE. USE MEDIA APPROPRIATE
FOR SURROUNDING FIRE.
Fire Fighting Procedures:EVACUATE ALL PERSONNEL FROM DANGER AREA.
IMMEDIATELY DELUGE CONTAINERS W/WTR SPRAY FROM MAX. DISTANCE
UNTIL COOL,THEN MOVE CONTAINERS AWAY FROM FIRE AREA.
Unusual Fire/Explosion Hazard:GAS CANNOT CATCH FIRE. CONTAINER MAY
RUPTURE DUE TO HEAT OF FIRE. NO PART OF A CONTAINER SHOULD REACH
TEMP OVER 125F. MOST CONTNRS DESIGNED TO VENT W/EXPOSED

Accidental Release

Spill Release Procedures:EVACUATE ALL PERSNL FROM DANGER AREA. USE SCBA
WHERE NEEDED. SHUT OFF LEAK IF W/O RISK. VENT AREAOF LEAK/MOVE
LEAKING CONTAINER TO WELL VENTL AREA.TEST AREA,ESPECIALLY CONFINED
AREA,FOR SUFFICIENT OXYGEN PRIOR TO PERMITTING RE-ENTRY OF
PERSONNEL.

Handling

Handling and Storage Precautions:NEVER WORK ON A PRESSURIZED SYSTEM. IF
THERE IS A LEAK,CLOSE THE CYLINDER VALVE,BLOW DOWN THE SYSTEMBY
VENTING TO A SAFE PLACE,THEN REPAIR THE LEAK.
Other Precautions:HIGH PRESSURE GAS. USE PIPING AND EQUIPMENT
ADEQUATELY DESIGNED TO WITHSTAND PRSURES TO BE ENCOUNTERED. CAN
CAUSE RAPID SUFFOCATION DUE TO OXYGEN DEFICIENCY.STORE AND USE
W/ADEQUATE VENTILATION. CL OSE VLV WHEN NOT IN USE & WHEN EMPTY.

Exposure Controls

Respiratory Protection:SELECT IN ACCORDANCE W/OSHA 29 CFR 1910.134.
RESPIRATORS SHALL BE ACCEPTABLE TO MSHA AND NIOSH.
Ventilation:LOCAL EXHAUST PREFERRED. MECHANICAL ACCEPTABLE
Protective Gloves:PREFERRED FOR CYLINDER HANDLING
Eye Protection:SELECT IN ACCRD. W/OSHA 29 CFR 1910.133
Other Protective Equipment:METATARSAL SHOES FOR CYLINDER HANDLING.
Supplemental Safety and Health
NK

Chemical Properties

Boiling Pt:B.P. Text:-320.46F
Vapor Pres:GAS
Vapor Density:0.967
Spec Gravity:GAS
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS, ODORLESS GAS AT NORMAL TEMPERATURE AND
PRESSURE
Percent Volatiles by Volume:NA

Stability

Stability Indicator/Materials to Avoid:YES
UNDER CERTAIN CONDITIONS, NITROGEN CAN REACT VIOLENTLY WITH LITHIUM,
NEODYMIUM, TITANIUM, OZONE.
Hazardous Decomposition Products:NONE

Disposal

Waste Disposal Methods:SLOWLY RELEASE INTO ATMOSPHERE. DISCARD ANY
PRODCTRESIDUE,DISPOSABLE CONTAINER OR LINER IN AN ENVIORMENTALLY
ACCEPTABLE MANNER,IN FULL COMPLIANCE WITHSTATE, AND LOCAL
REGULATIONS

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.