Product Identification

Product ID:ARGON
MSDS Date:10/01/1985
FSC:6830
NIIN:00-973-7274
MSDS Number: BHFBG

Responsible Party
LIQUID AIR CORPORATION
2121 N. CALIFORNIA BLVD., SUITE 350
WALNUT CREEK, CA 94596
US

Emergency Phone: 800-434-9300 OR NIGHT 800-231-1366

Info Phone: 415-977-6500

Cage: DO426

Contractor
WELCO GASES CORP.
WALNUT CREEK, CA 94596 US

Telephone: 510-977-6500

Cage: OC525

Ingredients

ARGON

CAS: 7440-37-1

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Explanation of Carcinogenicity:ARGON IS NONTOXIC BUT LIBERATION OF
LARGE AMOUNT IN A CONFNDAREA COULD DISPLACE AMOUNT OF OXYGEN IN AIR
Effects of Overexposure:LOSS OF BALANCE, DIZZINESS, TIGHTNESS IN
FRONTAL AREA OF FOREHEAD,TINGLING OF
TONGUE,FINGERTIPS,TOES,WEAKENED SPEECH LEADING TO UTTER SOUNDS,
RAPID REDUCTION IN MOVEMENTS, REDUCED CONSCIOUSNESS OF S
URROUNDING, LOSS OF TACTILE SENSATIONS,HEIGHTENED MENTAL ACTIVITY

First Aid

First Aid:PROMPT MEDICAL ATTENTION IS MANDATORY IN ALL CASES OF
OVEREXPOSURE TO AGRON. RESCUE PERSONNEL SHOULD BE EQUIPPED WITH
SCBA. INHALATION: QUICK REMOVAL FROM THE CONTAMINATED AREA IS
MOST IMPORTANT. UNCONSCIOUS PERSONS SHOULD BE MOVED TOAN
UNCONTAMINATED AREA, GIVEN MOUTH TO MOUTH RESUSCITATION &
SUPPLEMENTAL OXYGENMEDICAL ASSISTANCE SHOULD BE SOUGHT IMMEDIATELY.

Fire Fighting

Flash Point:NA
Lower Limits:NA
Upper Limits:NA
Extinguishing Media:NONFLAMMABLE INERT GAS
Fire Fighting Procedures:NA
Unusual Fire/Explosion Hazard:NA

Accidental Release

Spill Release Procedures:EVACUATE ALL PERSONNEL FROM AFFECTED AREA. IF
LEAKIS IN CONTAINER/CONTAINER VALVE, CONTACT THE CLOSEST
LIQUID AIR CORPORATION. USE APPROPRIATE PROTECTIVE EQUIPMENT

Handling

Handling and Storage Precautions:USE SUITABLE HANDTRUCK FOR CYLINDER
MOVEMENT. STORE IN COOL,DRY,WELL VENTILATED AREA AWAY FROM
HEAVY TRAFFICKED AREAS.
Other Precautions:PROTECT CYLINDERS FROM PHYSICAL DAMAGE. CYLINDERS
SHOULD BE STORED UPRIGHT & FIRMLY SECURED TO PREVENT FALLING.
FULL & EMPTY CYLINDERS SHOULD BE SEGREAGATED.DO NOT ALLOW TEMP
WHERE CYLINDERS ARE ST ORED TO EXCEED 130F (54C).

Exposure Controls

Respiratory Protection:POSITIVE PRESSURE AIR LINE W/MASK OR SELF
CONTAINED BREATHING APPARATUS SHOULD BE AVAILABLE FOR EMERGENCY
USE.
Ventilation:LOCAL EXHAUST TO PREVENT ACCUMULATION OF HIGH
CONCENTRATIONSSO AS TO REDUCE THE OXYGEN LEVEL IN THE AIR TO <18
MOLAR % .
Protective Gloves:ANY MATERIAL
Eye Protection:SAFETY GOGGLES/GLASSES
Other Protective Equipment:SAFETY SHOES
Supplemental Safety and Health
NK

Chemical Properties

Boiling Pt:B.P. Text:-302.55F
Vapor Pres:-188.12F
Vapor Density:.1034
Spec Gravity:1.38
Solubility in Water:.0340
Appearance and Odor:COLORLESS, ODORLESS GAS
Percent Volatiles by Volume:NA

Stability

Stability Indicator/Materials to Avoid:YES
NONE
Hazardous Decomposition Products:NONE

Disposal

Waste Disposal Methods:DO NOT ATTEMPT TO DISPOSE OF RESIDUAL/UNUSED
QYT. RETURN IN SHIPPING CONTNR PROPERLY LABELED, WITH VALVE OUTLET
PLUGS/CAPS SECURED & VALVE PROTECTIONCAP IN PLACE. CONTACT CLOSEST
LIQUID AIR CORP. FOR EMERGENCY DISPOSAL.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.