BHFCJ - INSTANTBOND

  • MSDS: BHFCJ
  • Manufacturer: HERON MANUFACTURING INC
  • Product Name: INSTANTBOND
  • National Stock Number: 8040-01-025-0237
Product Identification

Product ID:INSTANTBOND
MSDS Date:06/23/1989
FSC:8040
NIIN:01-025-0237
MSDS Number: BHFCJ

Responsible Party
HERON MANUFACTURING INC.
865 ESSEX STREET
BROOKLYN, NY 11208-5220
US

Emergency Phone: 718-649-3000

Info Phone: 718-649-3000

Cage: JO919

Contractor
HERON MANUFACTURING INC.
BROOKLYN, NY 11208-5220 US

Telephone: 718-649-3000

Cage: JO919

Ingredients

METHYL 2-CYANOACRYLATE

CAS: 137-05-3

RTECS: AS7000000

Fraction By Weight: > 90%

OSHA PEL 2 PPM/4 STEL

ACGIH TLV: 2 PPM/4 STEL; 9192

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Effects of Overexposure:EXPOSURE TO LIQUID; SKIN WILL BOND VERY RAPIDLY
TO ITSELF OR TO ALMOST ANYTHING ELSE IT IS IN CONTACT. IN EYES CAN
CAUSE IRRITATION. VAPOR, LACHRYMATORY EFFECT

First Aid

First Aid:SKIN: FLUSH IMMEDIATELY WITH WATER. CONTACT PHYSICIAN. EYE:
IRRIGATE IMMEDIATELYAND THOROUGHLY WITH WATER, HOLDING LIDS APART.
DO NOT FORCE APART IF BONDED. CONTACT PHYSICIAN. INHALATION: REMOVE
FROM EXPOSURE

Fire Fighting

Flash Point Method:COC
Flash Point:180 F 82 C
Extinguishing Media:DRY CHEMICAL, CO2, WATER SPRAY IF RESULTING
POLYMERIZATION WILL NOT BE HAZARDOUS
Fire Fighting Procedures:WEAR SELF CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING TO PREVENT CONTACT WITH SKIN OR EYES
Unusual Fire/Explosion Hazard:ADHESIVE IN ABSORBENT MATERIALS USED TO
WIPE UP SPILLS MAY UNDERGO POLYMERIZATION & CAUSE AN INCREASE IN
TEMP. THAT COULD CONCEIVABLY RESULT IN AUTOIGNITION

Accidental Release

Spill Release Procedures:ELIMINATE IGNITION SOURCES. USE DISPOSABLE
CLOTHS TO ABSORB ADHESIVE. INCINERATE IMMED OR STORE IN ACLOSED
METAL CONTAINER; CLOTHS CONTAINING ADHESIVE MAY UNDERGO
AUTOIGNITION. PROTECT EYES, SKIN & CL OTHS FROM CONTACT WITH
ADHESIVE.

Handling

Handling and Storage Precautions:AVOID CONTACT WITH SKIN, EYES, &
CLOTHING. AVOID BREATHING VAPOR. USE WITH VENTILATION ADEQUATE TO
MAINTAIN VAPOR CONCENTRATION BELOW TLV LIMIT
Other Precautions:IF SKIN BONDING OCCURS, ATTEMPTS TO FORCE SEPARATEION
MAY RESULT IN LOCAL MECHANICAL DAMAGE. REPEATE SOAKING OF BONDED
AREA IN WARM WATER MAY HASTEN TO LOOSEN BONDING. MATERIAL IS
CLASSIFIED AS COMBUS TIBLE MATERIAL

Exposure Controls

Respiratory Protection:A NIOSH APPROVED RESPIRATOR FOR ORGANIC VAPOR
SHOULD BE WORN IF NEEDED
Ventilation:LOCAL RECOMMENDED AND MECHANICAL RECOMMENDED
Protective Gloves:POLYETHYLENE GLOVES
Eye Protection:SAFETY GLASSES SHOULD BE WORN
Other Protective Equipment:EYE BATH
Supplemental Safety and Health
NK

Chemical Properties

Boiling Pt:B.P. Text:118-120 F
Vapor Pres:<2 @ 77 F
Vapor Density:3.8
Spec Gravity:1.1 @ 68 F
Evaporation Rate & Reference:NOT DETERMINED
Solubility in Water:NOT DETERMINED
Appearance and Odor:CLEAR-SLIGHTLY HAZY VIRTUALLY COLORLESS LIQUID;
PUNGENT UNPLEASANT ODOR. LACHRY
Percent Volatiles by Volume:98 MAX

Stability

Stability Indicator/Materials to Avoid:YES
OXIDIZING MATERIALS CAN CAUSE A VIGOROUS REACTION.
Hazardous Decomposition Products:COMBUSTION COULD RESULT IN FORMATION
OF CO2, CO, & OXIDES OFNITROGEN
Conditions to Avoid Polymerization:CONTAMINATION OF LIQUID W/ACIDIC OR
BASIC MATERIALS, PEROXIDES OR WTR CAN RESULT POLYMERIZATION
W/UNCONTROL RISE IN TEMP

Disposal

Waste Disposal Methods:INCINERATEION. OBSERVE ALL FED., STATE & LOCAL
LAWS CONCERING HEALTH AND POLLUTION

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.