BHFWF - PRO-SEAL 719-B, PART B
- MSDS: BHFWF
- Manufacturer: PRODUCTS RESEARCH AND CHEMICAL CORP
- Product Name: PRO-SEAL 719-B, PART B
- National Stock Number: 8030-01-105-9100
Product Identification
Product ID:PRO-SEAL 719-B, PART B
MSDS Date:02/10/1988
FSC:8030
NIIN:01-105-9100
Kit Part:Y
MSDS Number: BHFWF
Responsible Party
GLENDALE, CA 91209
US
Emergency Phone: 818-240-2060
Info Phone: 818-240-2060
Preparer: AS
Cage: 8K647
Contractor
Telephone: 800-228-5635
Cage: 8K647
Ingredients
EPOXY RESIN
CAS: 25068-38-6
RTECS: KC2100000
OSHA PEL NOT ESTAB
ACGIH TLV: NOT ESTAB
PHENOL-FORMALDEHYDE RESIN
CAS: 9003-35-4
OSHA PEL NOT ESTAB
ACGIH TLV: NOT ESTAB
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Effects of Overexposure:EYES: IRRI & SEVERE EYE DAMAGE. SKIN: SEVERE
IRRI. MAY BE A SKIN SENSITIZER. INHAL: HEADACHE, NAUSEA,
VOMITING & POSSIBLE DAMAGE TO PERIPHERAL NERVOUS SYSTEMINGESTION:
NONE OBSERVED
First Aid
First Aid:EYES: FLUSH WITH WATER. IF SYMPTOMS PERSISIT, CONSULT
PHYSICIAN. SKIN: WASH W/SOAP AND WATER. IF SYMPTOMS PERSISIT,
CONSULT PHYSICIAN. INHALATION: REMOVE TO FRESH AIR. IF SYMPTOMS ARE
PRESENT, CONSULT A PHYSICIAN. AND INGESTION: GIVE MILK OR WATER TO
DRINK
Fire Fighting
Flash Point Method:PMCC
Flash Point:188 F 87 C
Lower Limits:1.8
Upper Limits:11.5 (MEK)
Extinguishing Media:FOAM, CO2, DRY CHEMICAL, WATER SPRAY
Fire Fighting Procedures:NONE
Unusual Fire/Explosion Hazard:NONE
Accidental Release
Spill Release Procedures:SCOOP INTO CONTAINER. CLEAN UP RESIDUE WITH A
CHLORINATED SOLVENT.
Handling
Handling and Storage Precautions:NONE
Exposure Controls
Ventilation:GENERAL VENTILATION
Protective Gloves:SOLVENT RESISTANT GLOVES
Eye Protection:SAFETY GLASSES
Supplemental Safety and Health
NK
Chemical Properties
Vapor Density:2.42 (MEK)
Spec Gravity:1.40
Evaporation Rate & Reference:NA
Solubility in Water:SLIGHT
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS; STRONG OXIDIZING AGENTS
Hazardous Decomposition Products:OXIDES OF CARBON; SO2,; TRACES OF H2S
AND FORMALDEHYDE
Disposal
Waste Disposal Methods:NOT A HAZARDOUS WASTE ACCORDING TO EPA
REGULATIONSCONSULT STATE REGULATIONS PRIOR TO DISPOSAL OF SPILLAGE
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.