BHGGZ - EPOXY PRIMER, DP40

  • MSDS: BHGGZ
  • Manufacturer: PPG INDUSTRIES INC
  • Product Name: EPOXY PRIMER, DP40
  • National Stock Number: 8010-00F006623
Product Identification

Product ID:EPOXY PRIMER, DP40
MSDS Date:11/10/1987
FSC:8010
NIIN:00F006623
MSDS Number: BHGGZ

Responsible Party
PPG INDUSTRIES, INC
260 KAPPA DRIVE
PITTSBURGH, PA 15238

Emergency Phone: (304) 843-1300

Info Phone: (412) 963-5822

Cage: DO894

Contractor
PPG INDUSTRIES, INC.
9 ALLISON PARK, PA 15101 US

Telephone: 412-592-5555

Cage: DO894

Ingredients

TALC (CONTAINING NO ASBESTOS)

CAS: 14807-96-6

RTECS: WW2710000

Fraction By Weight: 5%

OSHA PEL 2 MG/M3 RDUST

ACGIH TLV: 2 MG/M3 RDUST; 9192


TITANIUM DIOXIDE

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: 10 - 15%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


BARIUM SULFATE

CAS: 7727-43-7

RTECS: CR0600000

Fraction By Weight: 10%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


STRONTIUM CHROMATE (SARA III)

CAS: 7789-06-2

RTECS: GB3240000

Fraction By Weight: 5%

OSHA PEL 0.1 PPM CRO3;CEILING

ACGIH TLV: 0.0005MG CR/M3;A2;93

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


PROPYLENE GLYCOL MONOMETHYL ETHER

CAS: 107-98-2

RTECS: UB7700000

Fraction By Weight: 5%

OSHA PEL 100 PPM/150 STEL

ACGIH TLV: 100 PPM/150STEL;9192


OXO-HEPTYL ACETATE

CAS: 90438-79-2

Fraction By Weight: 1%


ISOBUTYL ACETATE (SARA III)

CAS: 110-19-0

RTECS: AI4025000

Fraction By Weight: 15%

OSHA PEL 150 PPM

ACGIH TLV: 150 PPM; 9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ISOPROPYL ALCOHOL (SARA III)

CAS: 67-63-0

RTECS: NT8050000

Fraction By Weight: 5%

OSHA PEL 400 PPM/500 STEL

ACGIH TLV: 400 PPM/500STEL;9192


METHYL ETHYL KETONE (2-BUTANONE) (MEK) (SARA III)

CAS: 78-93-3

RTECS: EL6475000

Fraction By Weight: 15%

OSHA PEL 200 PPM/300 STEL

ACGIH TLV: 200 PPM/300STEL 9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


TOLUENE (SARA III)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 5 - 10%

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


FILM FORMERS, RESINS, & ADDITIVES

Fraction By Weight: 20%


CHROMIUM ION (CR 6+)

CAS: 18540-29-9

RTECS: GB6262000

Fraction By Weight: 5%

OSHA PEL C, 0.1 MG/M3 (CRO3)

ACGIH TLV: 0.05 MG/M3 (CR);8990

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:EYE: IRRITATION. INHALATION:
IRRITATION OF THE RESPIRATORY SYSTEM, PERMANENT BRAIN, NERVOUS
SYSTEM DAMAGE, EYES, NOSE, & THROAT, HEADACHES, NAUSEA, DIZZINESS,
& LOSS OF COORDINATION.
Explanation of Carcinogenicity:CHROMIUM (6+) COMPOUND & STRONTIUM
CHROMATE. HIGH LEVELS OF THESE MATERIALS W/AN INCREASED RISK OF
CANCER.
Effects of Overexposure:SKIN: PROLONGED/REPEATED CONTACT MAY CAUSE AN
ALLERGIC REACTION. INHALATION: VAPOR/SPRAY MIST/SANDING/GRINDING
DUSTS MAY BE HARMFUL. INTENTIONAL MISUSE BY DELIBERATELY
CONCENTRATING/INHALING THE CONTE NTS CAN BE HARMFUL OR FATAL.
SKIN/EYE IRRITATION/BREATHING DIFFICULTIES. INGESTION: EXPOSURE TO
A CORROSIVE MATERIAL.
Medical Cond Aggravated by Exposure:ALLERGIC SKIN REACTION

First Aid

First Aid:INGESTION: DON'T INDUCE VOMITING. EYE: FLUSH W/PLENTY OF
WATER FOR AT LEAST 15 MINS. SKIN: REMOVE PROMPTLY BY WIPING,
FOLLOWED BY WATERLESS HAND CLEANER, SOAP & WATER. INHALATION: IF
AFFECTED, REMOVE TO FRESH AIR. CONTACT POISON CONTROL CENTER.

Fire Fighting

Flash Point Method:PMCC
Flash Point:30F
Lower Limits:1.6%
Extinguishing Media:USE NFPA CLASS B EXTINGUISHERS CO2, DRY CHEMICAL,
OR UNIVERSAL AQUEOUS FILMING FORMING FOAM.
Fire Fighting Procedures:WATER SPRAY MAY BE INEFFECTIVE. IF WATER IS
USED, FOG NOZZLES ARE PREFERABLE. WEAR SCBA. DON'T APPLY ON HOT
SURFACES.
Unusual Fire/Explosion Hazard:WATER SPRAY MAY BE USED TO COOL CLOSED
CONTAINERS TO PREVENT PRESSURE BUILD-UP/POSSIBLE
AUTOIGNITION/EXPLOSION WHEN EXPOSED TO EXTREME HEAT.

Accidental Release

Spill Release Procedures:PROVIDE MAXIMUM VENTILATION. ONLY PERSONNEL
EQUIPPED W/PROPER RESP, SKIN/EYE PROTECTION SHOULD BE PERMITTED IN
THE AREA. REMOVE ALL SOURCES OF IGNITION. TAKE UP SPILLED MATERIAL
W/SAWDUST/VERMICULTIE/ OTHER ABSORBENT MATERIAL/PLACE INTO
CONTAINERS.

Handling

Handling and Storage Precautions:DON'T STORE >120F. STORE LARGE QTYS IN
BUILDINGS DESIGNED & PROTECTED FOR STORAGE OF NFPA CLASS IB
FLAMMABLE LIQUIDS. KEEP CONTAINERS TIGHTLY CLOSED.
Other Precautions:IF THIS MATERIAL IS PART OF A MULTIPLE COMPONENT
COATING SYSTEM, READ THE MATERIAL SAFETY DATA SHEETS FOR THE OTHER
COMPONENT OR COMPONENTS BEFORE BLENDING AS THE RESULTING MIXTURE
MAY HAVE THE HAZARD S OF ALL OF ITS PARTS.

Exposure Controls

Respiratory Protection:NIOSH/MSHA-APPROVED TC-23C PAINT SPRAY OR AIR
SUPPLIED TC-19C RESPIRATORS MAY ALSO REDUCE EXPOSURE. OVEREXPOSURE
TO VAPORS MAY BE PREVENTED BY ENSURING VENTILATION CONTROLS, VAPOR
EXHAUST OR FRESH AIR ENTRY.
Ventilation:PROVIDE MECHANICAL/LOCAL EXHAUST VENTILATION TO KEEP Protective Gloves:NEOPRENE, LATEX, POLYVINYL ALCOHOL
Eye Protection:CHEMICAL SPLASH GOGGLES, FULL FACESHIELD
Other Protective Equipment:CLEAN OR DISCARD CONTAMINATED CLOTHING &
SHOES.
Work Hygienic Practices:TO REMOVE DECOMPOSITION PRODUCTS DURING WELDING
OR FLAME CUTTING ON SURFACES COATED WITH THIS PRODUCT.
Supplemental Safety and Health
WT/GAL: 10.40 LBS.

Chemical Properties

Boiling Pt:B.P. Text:78-200C
Vapor Pres:37.9
Vapor Density:>AIR
Spec Gravity:1.25
Evaporation Rate & Reference:(BU AC = 100): 348
Solubility in Water:13.4%
Percent Volatiles by Volume:69.90%

Stability

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT W/STRONG ALKALIES, MINERAL ACIDS, OXIDIZING AGENTS.
Stability Condition to Avoid:TOXIC GASES MAY FORM WHEN PRODUCT IS
CONTACTED BY FLAME OR HOT SURFACES. HEAT, SPARKS, & OPEN FLAMES.
Hazardous Decomposition Products:MAY PRODUCE HAZARDOUS DECOMPOSITION
PRODUCTS WHEN HEATED. CO, HYDROGEN CHLORIDE CHLORINATED PRODUCTS,
CHLORINE, COX.

Disposal

Waste Disposal Methods:WASTE MATERIAL MUST BE DISPOSED OF IN ACCORDANCE
W/FEDERAL, STATE, & REGULATIONS. EMPTY CONTAINERS SHOULD BE
RECYCLED OR DISPOSED OF THROUGH AN APPROVED WASTE MANAGEMENT
FACILITY.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.