BHVBG - STRIPTHANE,8955

Product Identification

Product ID:STRIPTHANE,8955
MSDS Date:10/26/1987
FSC:8010
NIIN:00N010107
MSDS Number: BHVBG

Responsible Party
CALGON VESTAL LABORATORIES (DIVISION OF CALGON CO)
5035 MANCHESTER AVE.
ST.LOUIS, MO 63110

Emergency Phone: 314-535-1810

Info Phone: 314-535-1810

Preparer: DESTIN A LEBLANC

Cage: OB1W3

Contractor
CALGON VESTAL LABORATORIES
ST. LOUIS, MO 63110 US

Telephone: 314-535-1810;(SEE SUPP DATA)

Cage: OB1W3

Ingredients

CRESOL, ALL ISOMERS (CRESYLIC ACID) (SARA III)

CAS: 1319-77-3

RTECS: GO5950000

Fraction By Weight: 7.5%

OSHA PEL S, 5 PPM

ACGIH TLV: S, 5 PPM; 9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


FORMIC ACID (SARA III)

CAS: 64-18-6

RTECS: LQ4900000

Fraction By Weight: 7.5%

OSHA PEL 5 PPM

ACGIH TLV: 5 PPM/10 STEL; 9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


METHYLENE CHLORIDE (SARA III)

CAS: 75-09-2

RTECS: PA8050000

Fraction By Weight: 79%

OSHA PEL 500 PPM/C,1000; Z2

ACGIH TLV: 50 PPM, A2; 9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


TOLUENE (SARA III)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 5 - 10%

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

LD50 LC50 Mixture:N/K
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:HALOGENATED HYDROCARBONS MAY
PRECIPITATE CARDIAC ARRHYTHMIAS .
Explanation of Carcinogenicity:METHYLENE CHLORIDE:ACGIH A2=SUSP HUM
CARCIN (1989).INAD EVID FOR CARCIN IN HUM;SUFF EVID FOR CARCIN IN
ANIM (IARC,1987).
Effects of Overexposure:EYES:CAUSES BURNS.SKIN:CAUSES BURNS.INGEST:N/K
.INHAL:VAPORS ARE IRRITATING & PAINFUL.EXCESS VAPOR EXPOSURE CAUSES
IRRITATION TO RESPIRATORY TRACT & ANETHESIA (NARCOSIS).
Medical Cond Aggravated by Exposure:N/K

First Aid

First Aid:EYES:FLUSH W/ WATER FOR AT LEAST 15 MIN & GET MED ATTN
IMMED.SKIN:FLUSH W/ WATER & THEN WASH W/ SOAP & WATER.SEEK MED ATTN
IF IRRITATION PERSISTS.INGEST:GIVE 1-2 GLASSES MILK OR WATER.DO NOT
INDUCE VO MITING.GET MED ATTN IMMED.INHAL:MOVE TOFRESH AIR AND
CONTACT MD.

Fire Fighting

Flash Point Method:CC
Flash Point:NONE
Extinguishing Media:WATER FOG
Fire Fighting Procedures:WEAR PRESSURE DEMAND SELF-CONTAINED BREATHING
APPARATUS AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE HCL & PHOSGENE .

Accidental Release

Spill Release Procedures:SOAK UP WITH INERT ABSORBENT.

Handling

Handling and Storage Precautions:KEEP IN COOL PLACE.KEEP CONTAINER
CLOSED.KEEP AWAY FROM OPEN FLAME.DO NOT REUSE CONTAINER.SEND
CONTAINER TO RECONDITIONER OR BURY IN A SAFE PLACE.
Other Precautions:NO SMOKING IN AREA OF USE.DO NOT USE IN THE GENERAL
VICINITY OF ARC WELDING,OPEN FLAMES OR HOT SURFACES.HEAT/UV RADIA
MAY CAUSE FORMATION OF HCL/PHOSGENE .FOR INDUS & INSTITUTIONAL USE
ONLY.READ & OBSERVE LABELLED USE INSTRUCTIONS.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:LOCAL AND GENERAL VENTILATION NECESSARY TO KEEP AIR
CONCENTRATION BELOW TLV .
Protective Gloves:RUBBER
Eye Protection:CHEM WORK GOGG,FACESHLD OPTIONAL .
Other Protective Equipment:CHEMICAL APRON
Work Hygienic Practices:N/K
Supplemental Safety and Health
BP:100-390F,37.78-198.89C AT 14.7 PSIG.% VOLATILE BY WEIGHT:98.5.

Chemical Properties

Boiling Pt:B.P. Text:SEE SUPP
Melt/Freeze Pt:M.P/F.P Text:N/K
Decomp Temp:Decomp Text:N/K
Vapor Density:2.8,AIR=1
Spec Gravity:1.245 (WATER=1)
Evaporation Rate & Reference:3 (ETHER=1)
Solubility in Water:IMMISCIBLE
Appearance and Odor:VISCOUS LIQUID,PUNGENT ODOR.

Stability

NONE KNOWN
Stability Condition to Avoid:NONE KNOWN
Hazardous Decomposition Products:HCL, PHOSGENE .
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH
FEDERAL,STATE AND LOCAL REGULATIONS .BURY AWAY FROM WATER SUPPLY OR
ALLOW SOLVENT TO EVAPORATE TO ATMOSPHERE AWAY FROM INHABITED
BUILDINGS (MFR).

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.