BHWJD - NITROGEN
- MSDS: BHWJD
- Manufacturer: AIR PRODUCTS AND CHEMICALS INDUSTRIAL GAS DIV
- Product Name: NITROGEN
- National Stock Number: 6830-00-787-2643
Product Identification
Product ID:NITROGEN
MSDS Date:06/01/1989
FSC:6830
NIIN:00-787-2643
MSDS Number: BHWJD
Responsible Party
ALLENTOWN, PA 18197-1501
US
Emergency Phone: 800-523-9374/800-322-9092(PA)
Info Phone: 215-481-4911
Cage: 00742
Contractor
Telephone: 800-345-3148/ 800-752-1597
Cage: 5H199
Ingredients
NITROGEN
CAS: 7727-37-9
RTECS: QW9700000
Fraction By Weight: 100%
ACGIH TLV: ASPHYXIANT; 9192
Hazards
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NITROGEN IS A SIMPLE ASPHYXIANT.
NITROGEN UNDER HIGH PRESSURE CAN PRODUCE NARCOSIS.
Explanation of Carcinogenicity:NONE OF THE CHEMICALS IN THIS PRODUCT IS
LISTED BY IARC, NTP OR OSHA AS A CARCINOGEN.
Effects of Overexposure:INHALATION:DIZZINESS, NAUSEA, VOMITING, LOSS OF
CONSCIOUSNESS, AND DEATH.
Medical Cond Aggravated by Exposure:NONE NOTED.
First Aid
First Aid:INHALATION: REMOVE SUBJECT TO FRESH AIR. RESCUE WORKERS, WEAR
SCBA. GIVE OXYGEN/CPR AS NEEDED.
Fire Fighting
Autoignition Temp:Autoignition Temp Text:NONE
Extinguishing Media:AS APPROPIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER
SPRAY TO COOL NEARBY CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:CYLINDERS MAY EXPLODE IN HEAT OF FIRE.
Accidental Release
Spill Release Procedures:VENTILATE ENCLOSED AREAS TO PREVENT FORMATION
OF OXYGEN-DEFICIENT ATMOSPHERES CAUSED BY THE RELEASE OF GASEOUS
NITROGEN.
Neutralizing Agent:NONE APPLICABLE FOR THIS MATERIAL
Handling
Handling and Storage Precautions:USE ONLY IN WELL VENTILATED AREAS.
CONTAINS NITROGEN AT EXTREMELY HIGH PRESSURE.HANDLE WITH CARE.
Other Precautions:AVOID DRAGGING,ROLLING OR SLIDING CYLINDERS.USE HAND
TRUCK.STORE OUTSIDE.KEEP AWAY FROM HEAT,FLAMES AND COMBUSTIBLE
MATERIALS.KEEP AWAY FROM HEAVY TRAFFIC AREAS.AVOID EXPOSURE TO SALT
OR OTHER CORROSI VE CHEMICALS.REPLACE CAP WHEN NOT IN USE
Exposure Controls
Respiratory Protection:USE SCBA IN OXYGEN-DEFICIENT ATMOSPHERES.
CAUTION! RESPIRATORS WILL NOT FUNCTION.USE MAY RESULT IN
ASPHYXIATION.
Ventilation:MECHANICAL (GENERAL) VENTILATION AND/OR LOCAL EXHAUST AS
NECESSARY.
Protective Gloves:LEATHER WORK GLOVES.
Eye Protection:SAFETY GLASSES.
Other Protective Equipment:OXYGEN MONITORING EQUIPMENT TO TEST FOR
OXYGEN DEFICIENT ATMOSPHERES.
Work Hygienic Practices:STANDARD HYGENIC PRACTICES.
Supplemental Safety and Health
NONE.
Chemical Properties
HCC:G3
Boiling Pt:B.P. Text:-320F,-196C
Melt/Freeze Pt:M.P/F.P Text:-346F,-210C
Vapor Density:0.07245
Spec Gravity:0.967
Solubility in Water:1.52%
Appearance and Odor:COLORLESS, ODORLESS GAS.
Stability
Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:NONE.
Disposal
Waste Disposal Methods:VENT NITROGEN GAS SLOWLY TO A WELL VENTILATED
OUTODOOR LOCATION REMOTE FROM WORK AREAS. DO NOT DISPOSE OF
RESIDUAL NITROGEN IN CYLINDERS. RETURN TO MANUFACTURER WITH
RESIDUAL PRESSURE, VALVE TIGHTLY C LOSED, AND VALVE CAPS IN PLACE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.