BJBYD - UNITE LIGHT CURED MATERIAL RESIN
- MSDS: BJBYD
- Manufacturer: HENRY SCHEIN INC
- Product Name: UNITE LIGHT CURED MATERIAL RESIN
- National Stock Number: 6520-00F012224
Product Identification
Product ID:UNITE LIGHT CURED MATERIAL RESIN
MSDS Date:01/01/1987
FSC:6520
NIIN:00F012224
MSDS Number: BJBYD
Responsible Party
PORT WASHINGTON, NY 11050
Emergency Phone: (516) 621-4300
Info Phone: (516) 621-4300
Cage: 64682
Contractor
Telephone: (516) 621-4300
Cage: 64682
Ingredients
TRIETHYLENE GLYCOL DIMETHACRYLATE
CAS: 109-16-0
RTECS: OZ4100000
BISPHENOL A GLYCIDYLMETHACRYLATE, BIS-GMA
CAS: 1565-94-2
RTECS: UD3438000
BENZOYL PEROXIDE, DI-BENZOYLPEROXIDE
CAS: 94-36-0
RTECS: DM8575000
OSHA PEL 5 MG/CUM
ACGIH TLV: 5 MG/CUM
Hazards
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN: ALLERGIES TO METHACRYLATES.
INGESTION: DYSPEPSIA, NAUSEA, & VERTIGO.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:SKIN: ALLERGIES TO METHACRYLATES. INGESTION:
DYSPEPSIA, NAUSEA, & VERTIGO.
Medical Cond Aggravated by Exposure:ALLERGIES
First Aid
First Aid:SKIN: WASH W/SOAP & WATER. EYES: RINSE W/WATER. CONSULT
PHYSICIAN.
Fire Fighting
Flash Point:>110C
Extinguishing Media:CO2, SAND, DRY CHEMICAL
Fire Fighting Procedures:FIGHT LIKE FUEL OIL FIRE.
Accidental Release
Spill Release Procedures:ABSORB W/INERT MATERIALS, DRY SAND. PLACE IN
CLOSED CONTAINER FOR DISPOSAL AS SOLID WASTE.
Handling
Handling and Storage Precautions:USE ACCORDING TO DIRECTIONS.
Other Precautions:NONE
Exposure Controls
Respiratory Protection:NONE
Ventilation:NONE
Work Hygienic Practices:USE ACCORDING TO DIRECTIONS.
Supplemental Safety and Health
Chemical Properties
Boiling Pt:B.P. Text:GELS
Spec Gravity:1.1
Evaporation Rate & Reference:(BU AC = 1): <1
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR, VISCOUS, YELLOWISH LIQUID, NEARLY ODORLESS.
Stability
Stability Indicator/Materials to Avoid:NO
STRONG ACIDS, AMINES, REDUCING AGENTS
Stability Condition to Avoid:SUNLIGHT, HEAT, CONTAMINATION
Disposal
Waste Disposal Methods:MIX W/INERT FILLER & REMOVE TO OPEN AREA. ALLOW
TIME TO GEL & CURE. USE PROPER LANDFILL DISPOSAL & INCINERATION IN
ACCORDANCE W/LOCAL, STATE, & FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.