Product Identification
Product ID:N-29
MSDS Date:09/01/1989
FSC:8040
NIIN:01-017-1508
Kit Part:Y
MSDS Number: BJJGH
Responsible Party
WILMINGTON, DE 19801
US
Emergency Phone: 302-656-9951
Info Phone: 302-656-9951
Cage: 88112
Contractor
Telephone: 203-433-1000
Cage: 96169
Ingredients
TOLUENE (SARA III)
CAS: 108-88-3
RTECS: XS5250000
Fraction By Weight: 45 - 50%
OSHA PEL 200 PPM/150 STEL
ACGIH TLV: 50 PPM; 9293
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
VM&P NAPTHA.
CAS: 64742-89-8
Fraction By Weight: 10%
OSHA PEL 300 PPM
ACGIH TLV: 300 PPM
LACTOL SPIRITS.
CAS: 64742-89-8
Fraction By Weight: 10%
OSHA PEL 300 PPM
ACGIH TLV: 300 PPM
HYDRATED AMORPHOUS SILICA
CAS: 63231-67-4
Fraction By Weight: 5%
OSHA PEL 6 MG/M3
ACGIH TLV: 5 MG/M3
XYLENES (O-,M-,P- ISOMERS) (SARA III)
CAS: 1330-20-7
RTECS: ZE2100000
Fraction By Weight: <5%
OSHA PEL 100 PPM/150 STEL
ACGIH TLV: 100 PPM/150STEL;9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
LD50 LC50 Mixture:SEE INGREDIENTS.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE: IRRITATION. SKIN: PRLNGD OR RPTD
CONTACT MAY CAUSE DERMATITIS AND IRRITATION. INHAL: RESP TRACT
IRRIT AND ANESTHETIC AND CAUSES CNS DEPRESSION. INGEST: MAY CAUSE
LIVER AND/OR KIDNEY DAMAGE.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:ANY PRE-EXISTING HEART OR SKIN
CONDITION OR AN IMPAIRED LUNG FUNCTION.
First Aid
First Aid:EYES: FLUSH W/LG AMTS OF WATER FOR 15 MINUTES. SEE MD. SKIN:
WASH THORO W/SOAP & WATER. INHAL:REMOVE TO FRESH AIR. SUPPORT
BREATHING (O*2/ARTIFICIAL RESP). SEE MD. INGEST: SEE MD.
Fire Fighting
Flash Point Method:SCC
Flash Point:37.0F,2.8C
Lower Limits:0.9%
Upper Limits:7.0%
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT. .
Unusual Fire/Explosion Hazard:VAPORS MAY TRAVEL CONSIDERABLE DISTANCE
TO A SOURCE OF IGNITION AND FLASH BACK.
Accidental Release
Spill Release Procedures:ABSORB ON SUITABLE INERT MATERIAL. REMOVE ALL
SOURCES OF IGNITION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP AND STORE IN A COOL DRY PLACE
AWAY FROM SOURCES OF IGNITION. GROUND DURING TRANSFER.
Other Precautions:RPTD AND PRLNGD OVER EXPOSURE TO SOLVENTS MAY CAUSE
BRAIN AND NERVOUS SYSTEM DAMAGE. CONCENTRATING AND INHALING THE
CONTENTS MAY BE HARMFUL OR FATAL.
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED CARTRIDGE RESPIRATOR
UNLESS AIR MONITORING DEMONSTRATES THAT VAPOR/MIST LEVELS ARE
WITHIN APPLICABLE LIMITS.
Ventilation:MECHANICAL/GENERAL VENTILATION.
Protective Gloves:IMPERMEABLE
Eye Protection:CHEMICAL WORKERS GOGGLES.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE
Chemical Properties
Boiling Pt:B.P. Text:215F,102C
Vapor Density:>1
Spec Gravity:0.9
Evaporation Rate & Reference:<1 BUTYL ACETATE=1
Solubility in Water:INSOLUBLE
Appearance and Odor:BLACK VISCOUS LIQUID W/CHARACTERISTIC
Percent Volatiles by Volume:80-85
Stability
Stability Indicator/Materials to Avoid:NO
STRONG OXIDIZING AGENTS, STRONG ACIDS.
Stability Condition to Avoid:SPARKS, OPEN FLAMES OR HOT SURFACES.
Hazardous Decomposition Products:CARBON MONOXIDE, HYDROGEN CHLORIDE,
AND PHOSGENE.
Disposal
Waste Disposal Methods:DISPOSE OF I/A/W FEDERAL, STATE & LOCAL
REGULATIONS
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.