BJQZZ - CHEM-WIK

  • MSDS: BJQZZ
  • Manufacturer: CHEMTRONICS INC
  • Product Name: CHEM-WIK
  • National Stock Number: 6810-00D002727
Product Identification

Product ID:CHEM-WIK
MSDS Date:08/01/1987
FSC:6810
NIIN:00D002727
MSDS Number: BJQZZ

Responsible Party
CHEMTRONICS INC
8125 COBB CENTERR ROAD
KENNESAW, GA 30144
US

Emergency Phone: 404-424-4888

Info Phone: 404-424-4888

Preparer: H. ALPER

Cage: 2M589

Contractor
CHEMTRONICS INC (CANCELLED USE 21267)
HAUPPAUGE, NY 11760 US

Telephone: 770-424-4888/800-645-5244

Cage: 2M589

Ingredients

COPPER (SARA III)

CAS: 7440-50-8

RTECS: GL5325000

OSHA PEL 0.1MG/M3 FUME/1 DUST

ACGIH TLV: 0.2MG/M3 FUME; 9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ROSIN

OSHA PEL 0.1 MG/M3

ACGIH TLV: 0.1 MG/M3; 9091

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION OF DUST OR FUMES DURING
DESOLDERING CAN BE A RESPIRATORY TRACT IRRITANT. LONG-TERM ACUTE
OVEREXPOSURE TO FUMES DURING DESOLDERING CAN CAUSE LEAD POISONING.
SKIN CONTACT CAN CAUSE ALLERGIC R EACTION IN CERTAIN INDIVIDUALS.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO INGREDIENTS AT
CONCENTRATIONS OF 0.1% OR GREATER THAT ARE CARCINOGENS OR SUSPECT
CARCINOGENS.
Effects of Overexposure:MAY CAUSE EYE, SKIN & RESPIRATORY TRACT
IRRITATION AND HEADACHE. LEAD POISONING IS EVIDENCED BY WEAKNESS,
LASSITUDE, INSOMNIA, FACIAL PALLOR, ANOREXIA, LOW WEIGHT,
MALNUTRITION, CONSTIPATION, ABDOMINA L PAIN, COLIC, ANEMIA,
GINGIVAL LEAD LINE, TREMOR, PARALYSIS OF THE WRIST & ANKLES,
ENCEPHALOPATHY, AND NEPHROPATHY.
Medical Cond Aggravated by Exposure:PERSONS WITH A HISTORY OF AILMENTS
OR WITH A PRE-EXISTING DISEASE INVOLVING THE STOMACH, BLOOD,
KIDNEYS OR CENTRAL NERVOUS SYSTEM MAY BE AT INCREASED RISK FROM
REPEATED AND PROLONGED DESOLDERING.

First Aid

First Aid:EYES: FLUSH WITH RUNNING WATER FOR 15 MINUTES WHILE HOLDING
EYELIDS OPEN. GET MEDICAL ATTENTION IMMEDIATELY. SKIN: WASH WITH
SOAP AND WATER. REMOVE CONTAMINATED CLOTHING. GET MEDICAL ADVICE.
INHALATIO N: REMOVE TO FRESH AIR. GET MEDICAL ATTENTION IF
IRRITATION CONTINUES. INGESTION: SEEK MEDICAL ATTENTION FOR ACUTE
ORAL INGESTION OF DUST OR FUMES.

Fire Fighting

Flash Point Method:TOC
Flash Point:400F(ROSIN)
Extinguishing Media:USE WATER FOG, CARBON DIOXIDE, FOAM, OR DRY
CHEMICAL.
Fire Fighting Procedures:WEAR FIRE FIGHTING PROTECTIVE EQUIPMENT AND A
FULL FACED SELF CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:NONE

Handling

Handling and Storage Precautions:STORE IN A DRY ENVIRONMENT.
Other Precautions:BREATHING HEAVY CONCENTRATIONS OF DUST OR FUMES
DURING DESOLDERING SHOULD BE AVOIDED. WORK SHOULD BE DONE UNDER
FUME HOOD WITH AIR VELOCITY EQUAL TO 200 FT/MIN THRU HOOD OPENING.

Exposure Controls

Respiratory Protection:NONE NORMALLY REQUIRED.
Ventilation:WORK SHOULD BE DONE UNDER FUME HOOD WITH AIR VELOCITY EQUAL
TO 200 FT/MIN THRU HOOD OPENING.
Protective Gloves:NONE NORMALLY REQUIRED.
Eye Protection:SAFETY GLASSES RECOMMENDED.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH THOROUGHLY AFTER USING AND BEFORE EATING,
DRINKING OR SMOKING. KEEP WORK AREA CLEAN.
Supplemental Safety and Health
AVOID PROLONGED OR REPEATED EXPOSURE TO FUMES WHEN DESOLDERING.

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:604F(ROSIN)
Vapor Pres:0
Vapor Density:<1 (ROSIN)
Spec Gravity:1.07(ROSIN)
pH:<7
Solubility in Water:NEGLIGIBLE
Appearance and Odor:BRAIDED COPPER WIRE WITH THIN TRANSPARENT COATING
OF WATER WHITE ROSIN.
Percent Volatiles by Volume:0

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS AND STRONG ACIDS
Hazardous Decomposition Products:CARBON MONOXIDE AND CARBON DIOXIDE

Disposal

Waste Disposal Methods:DISPOSAL MUST BE MADE IN ACCORDANCE WITH
APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.