BJQZZ - CHEM-WIK
- MSDS: BJQZZ
- Manufacturer: CHEMTRONICS INC
- Product Name: CHEM-WIK
- National Stock Number: 6810-00D002727
Product Identification
Product ID:CHEM-WIK
MSDS Date:08/01/1987
FSC:6810
NIIN:00D002727
MSDS Number: BJQZZ
Responsible Party
KENNESAW, GA 30144
US
Emergency Phone: 404-424-4888
Info Phone: 404-424-4888
Preparer: H. ALPER
Cage: 2M589
Contractor
Telephone: 770-424-4888/800-645-5244
Cage: 2M589
Ingredients
COPPER (SARA III)
CAS: 7440-50-8
RTECS: GL5325000
OSHA PEL 0.1MG/M3 FUME/1 DUST
ACGIH TLV: 0.2MG/M3 FUME; 9192
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ROSIN
OSHA PEL 0.1 MG/M3
ACGIH TLV: 0.1 MG/M3; 9091
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION OF DUST OR FUMES DURING
DESOLDERING CAN BE A RESPIRATORY TRACT IRRITANT. LONG-TERM ACUTE
OVEREXPOSURE TO FUMES DURING DESOLDERING CAN CAUSE LEAD POISONING.
SKIN CONTACT CAN CAUSE ALLERGIC R EACTION IN CERTAIN INDIVIDUALS.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO INGREDIENTS AT
CONCENTRATIONS OF 0.1% OR GREATER THAT ARE CARCINOGENS OR SUSPECT
CARCINOGENS.
Effects of Overexposure:MAY CAUSE EYE, SKIN & RESPIRATORY TRACT
IRRITATION AND HEADACHE. LEAD POISONING IS EVIDENCED BY WEAKNESS,
LASSITUDE, INSOMNIA, FACIAL PALLOR, ANOREXIA, LOW WEIGHT,
MALNUTRITION, CONSTIPATION, ABDOMINA L PAIN, COLIC, ANEMIA,
GINGIVAL LEAD LINE, TREMOR, PARALYSIS OF THE WRIST & ANKLES,
ENCEPHALOPATHY, AND NEPHROPATHY.
Medical Cond Aggravated by Exposure:PERSONS WITH A HISTORY OF AILMENTS
OR WITH A PRE-EXISTING DISEASE INVOLVING THE STOMACH, BLOOD,
KIDNEYS OR CENTRAL NERVOUS SYSTEM MAY BE AT INCREASED RISK FROM
REPEATED AND PROLONGED DESOLDERING.
First Aid
First Aid:EYES: FLUSH WITH RUNNING WATER FOR 15 MINUTES WHILE HOLDING
EYELIDS OPEN. GET MEDICAL ATTENTION IMMEDIATELY. SKIN: WASH WITH
SOAP AND WATER. REMOVE CONTAMINATED CLOTHING. GET MEDICAL ADVICE.
INHALATIO N: REMOVE TO FRESH AIR. GET MEDICAL ATTENTION IF
IRRITATION CONTINUES. INGESTION: SEEK MEDICAL ATTENTION FOR ACUTE
ORAL INGESTION OF DUST OR FUMES.
Fire Fighting
Flash Point Method:TOC
Flash Point:400F(ROSIN)
Extinguishing Media:USE WATER FOG, CARBON DIOXIDE, FOAM, OR DRY
CHEMICAL.
Fire Fighting Procedures:WEAR FIRE FIGHTING PROTECTIVE EQUIPMENT AND A
FULL FACED SELF CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:NONE
Handling
Handling and Storage Precautions:STORE IN A DRY ENVIRONMENT.
Other Precautions:BREATHING HEAVY CONCENTRATIONS OF DUST OR FUMES
DURING DESOLDERING SHOULD BE AVOIDED. WORK SHOULD BE DONE UNDER
FUME HOOD WITH AIR VELOCITY EQUAL TO 200 FT/MIN THRU HOOD OPENING.
Exposure Controls
Respiratory Protection:NONE NORMALLY REQUIRED.
Ventilation:WORK SHOULD BE DONE UNDER FUME HOOD WITH AIR VELOCITY EQUAL
TO 200 FT/MIN THRU HOOD OPENING.
Protective Gloves:NONE NORMALLY REQUIRED.
Eye Protection:SAFETY GLASSES RECOMMENDED.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH THOROUGHLY AFTER USING AND BEFORE EATING,
DRINKING OR SMOKING. KEEP WORK AREA CLEAN.
Supplemental Safety and Health
AVOID PROLONGED OR REPEATED EXPOSURE TO FUMES WHEN DESOLDERING.
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:604F(ROSIN)
Vapor Pres:0
Vapor Density:<1 (ROSIN)
Spec Gravity:1.07(ROSIN)
pH:<7
Solubility in Water:NEGLIGIBLE
Appearance and Odor:BRAIDED COPPER WIRE WITH THIN TRANSPARENT COATING
OF WATER WHITE ROSIN.
Percent Volatiles by Volume:0
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS AND STRONG ACIDS
Hazardous Decomposition Products:CARBON MONOXIDE AND CARBON DIOXIDE
Disposal
Waste Disposal Methods:DISPOSAL MUST BE MADE IN ACCORDANCE WITH
APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.