BKNPJ - TEFLON PRIMERS (458-500)
- MSDS: BKNPJ
- Manufacturer: E I DUPONT DE NEMOURS AND CO
- Product Name: TEFLON PRIMERS (458-500)
- National Stock Number: 8010-00N015181
Product Identification
Product ID:TEFLON PRIMERS (458-500)
MSDS Date:01/01/1987
FSC:8010
NIIN:00N015181
MSDS Number: BKNPJ
Responsible Party
WILMINGTON, DE 19898
US
Emergency Phone: 800-441-3637;800-424-9300(CHEMTREC)
Info Phone: 800-441-7515
Cage: 0ERJ7
Contractor
Telephone: 800-441-7515;800-441-9442
Cage: 18873
Ingredients
XYLENES (O-,M-,P- ISOMERS) (SARA III)
CAS: 1330-20-7
RTECS: ZE2100000
OSHA PEL 100 PPM/150 STEL
ACGIH TLV: 100 PPM/150STEL;9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
OCTYLPHENOXYPOLYETHOXYETHANOL (NONIONIC SURFACTANT)
CALL MD IMMED & HAVE NAMES OF INGRED
RTECS: 9999999ZZ
LUNG DMG, PULM EDEMA/BURNS. SOME VEGETATION IS
RTECS: 9999999ZZ
AMORPHOUS
RTECS: 9999999ZZ
MAY CAUSE EYE IRRIT W/DISCOMFORT, TEARING/BLURRED
RTECS: 9999999ZZ
RASH. CAN BE ABSORBED THROUGH THE SKIN IN HARMFUL
RTECS: 9999999ZZ
OVEREXP MAY CAUSE EYE, NOSE & THROAT IRRIT.
RTECS: 9999999ZZ
CAUSE CNS EFTS SUCH AS DIZZ, HDCH, NAUS & LOSS OF
RTECS: 9999999ZZ
OVEREXP MAY CAUSE EYE, NOSE & THROAT IRRIT.
RTECS: 9999999ZZ
DERMAT. MAY CAUSE CNS EFTS SUCH AS DIZZ, HDCH, NAUS
RTECS: 9999999ZZ
RPTD & PRLNGD OVEREXP TO SOLV W/PERM BRAIN & NERV
RTECS: 9999999ZZ
IN LAB ANIMALS. RECURRENT OVEREXP MAY RESULT IN
RTECS: 9999999ZZ
CAUSES EYE CORR & PERM
RTECS: 9999999ZZ
FULL LGTH FSHLD TO GOG
SILICA GEL (AMORPHOUS SILICA)
CAS: 112945-52-5
RTECS: VV7310000
OSHA PEL 6 MG/M3
ACGIH TLV: 10.0 MG/M3 TDUST
ETHANOL,2-(2-BUTOXYETHOXY)-2-(2-BUTOXY ETHOXY) ETHANOL. VP
CAS: 112-34-5
RTECS: KJ9100000
OSHA PEL 5.0 PPM (MFR)
ACGIH TLV: 5.0 PPM (MFR)
0.01.
CAS: 102-71-6
RTECS: KL9275000
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL: NORMALLY NOT A HAZARD. THESE
PRODUCTS CONTAIN SM AMTS OF SOLV AS DESCRIBED BELOW. SKIN/EYE: MAY
CAUSE IRRIT/BURNING OF EYES. RPTD/PRLNG LIQ CONT MAY CAUSE SKIN
IRRIT W/DISCOMFORT & DERMAT. OTHE R POTENTIAL HAZ (OF THE PURE
MATLS) INCLUDE: ING 1: EXPOS TO TEFLON DECOMP PRODS CAN CREATE (SEE
EFTS OF OVEREXP)
Explanation of Carcinogenicity:NONE SPECIFIED BY MANUFACTURER.
Effects of Overexposure:HLTH HAZ: INFLUENZA-LIKE SYMPTOMS, COMMONLY
REFERRED TO AS POLYMER FUME FEVER. THESE SYMPTOMS DO NOT ORDINARILY
OCCUR UNTIL SEV HRS AFTER EXPOS & PASS WITHIN 36-48 HRS. EFTS ARE
NOT CUMULATIVE. EXPOS USUALLY RESULTS FROM SMOKING TOBACCO
ORCIGARETTES CONTAM W/THE FLUOROCARBON DURING HANDLING OR FROM
BRTHG (SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL: IF AFFECTED BY INHAL OF VAP/SPRAY MIST, REMOVE TO
FRESH AIR. IF NOT BRTHG, GIVE ARTF RESP, PREF MOUTH-TO-MOUTH. IF
BRTHG DIFFICULTY PERSISTS, OR OCCURS LATER, CALL MD. SKIN/EYE: IN
CASE OF EYE CONT, IMMED FLUSH W/PLENTY OF WATER FORAT LEAST 15
MIN, CALL MD. IN CASE OF SKIN CONT, WASH W/SOAP & WATER. IF IRRIT
OCCURS, CALL MD. INGEST: GI DISTRESS. IN THE UNLIKELY EVENT OF
INGEST, (SEE ING 7)
Fire Fighting
Flash Point:NONE
Extinguishing Media:FOAM, CO*2, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL PROT
EQUIP . WATER FROM FOG NOZZLES MAY BE USED TO COOL CLOSED CNTNRS TO
PREVENT PRESSURE BUILD-UP.
Unusual Fire/Explosion Hazard:HYDROGEN FLUORIDE IS RELEASED DURING A
FIRE.
Accidental Release
Spill Release Procedures:VENTILATE AREA. REMOVE SOURCES OF IGNITION.
AVOID SKIN CONTACT AND BREATHING OF VAPOR. CONFINE AND REMOVE WITH
INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:OBSERVE LABEL PREC. KEEP AWAY FROM
HEAT, SPARKS & FLAME. CLOSE CNTNR AFTER EACH USE. GROUND CNTNRS
WHEN POURING. DO NOT STORE ABOVE 120F.
Other Precautions:EXPLOSIVE RXN MAY OCCUR ABOVE 796F W/FINELY DIVIDED
FLUOROCARBON & METAL POWDER (ALUMINUM OR MAGNESIUM). OPERATIONS
SUCH AS GRINDING, BUFFING OR GRIT BLASTING MAY GENERATE SUCH
MIXTURES. KEEP WET. USE ADEQUATE VENTILATION TO CONTROL.
Exposure Controls
Respiratory Protection:DO NOT BREATHE VAP/MISTS. WEAR A PROPERLY FITTED
NIOSH/MSHA APPRVD VAPOR/PARTICULATE RESP FOR USE WITH PAINTS DURING
APPLICATN & UNTIL ALL VAPS & SPRAY MIST ARE EXHAUSTED. FOLLOW RESP
MFR DIRECTIONS F OR RESP USE.
Ventilation:PROVIDE SUFFICIENT VENTILATION IN VOLUME & PATTERN TO KEEP
CONTAMINANTS BELOW APPLICABLE OSHA REQUIREMENTS.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:CHEM WORKERS GOG. MAY ADD (SEE ING 1)
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE
EATING AND SMOKING.
Supplemental Safety and Health
% VOLAT: 51.1-53.7%. EFTS OF OVEREXP: VAPS EMITTED DURING BAKING. DO
NOT EXCEED REC BAKING TEMP. BAKING OVENS MUST BE PROPERLY VENT. AT
TEMP ABOVE 400C (750F) SM AMTS OF HYDROGEN FLUORIDE CAN BE EVOLV
ED; AMTS INCREASE AS TEMP INCREASES. HYDROGEN FLUORIDE IS TOXIC &
CAN CAUSE SKIN & EYE IRRIT (3 PPM CEILING (SEE ING 7)
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:212F,100C
Vapor Pres:SEE INGRED
Vapor Density:>AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:APPRECIABLE
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:SUPDAT
Stability
Stability Indicator/Materials to Avoid:YES
NONE REASONABLY FORESEEABLE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:OXIDES OF HEAVY METALS.
Disposal
Waste Disposal Methods:DO NOT ALLOW MATL TO CONTAMINATE GROUND WATER
SYSTEMS. SEND TO HAZ WASTE WATER TREATMENT PLANT OR INCINERATE
ABSORBED MATL IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL
REQUIREMENTS. DO NOT INCINERATE I N CLOSED CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.