BKQPQ - AMMONIA
- MSDS: BKQPQ
- Manufacturer: AIR PRODUCTS AND CHEMICALS INC
- Product Name: AMMONIA
- National Stock Number: 6830-00N016541
Product Identification
Product ID:AMMONIA
MSDS Date:02/01/1988
FSC:6830
NIIN:00N016541
MSDS Number: BKQPQ
Responsible Party
ALLENTOWN, PA 18195
US
Emergency Phone: 800-523-9374,800-322-9092
Info Phone: 215-481-8257
Cage: 00742
Contractor
Telephone: 800-345-3148/ 800-752-1597
Cage: 00742
Ingredients
REGULATOR WHEN CONNECTING CYL TO LOWER PRESS (<500
RTECS: 9999999ZZ
INCR DISCHARGE RATE FROM CYL. USE CHECK VALVE OR
RTECS: 9999999ZZ
CYL. PROT CYLS FROM PHYS DMG. STORE IN
RTECS: 9999999ZZ
HEAVILY TRAVELED AREAS/EMER EXITS. DO NOT ALLOW TEMP
RTECS: 9999999ZZ
BE STORED UPRIGHT/FIRMLY SECURED TO PREVENT FALLING
RTECS: 9999999ZZ
SEGREGATED. USE "FIRST IN-FIRST OUT" INVENTORY
RTECS: 9999999ZZ
PERIODS OF TIME.POST "NO SMKNG OR OPEN FLAMES" SIGNS
RTECS: 9999999ZZ
A COMPRESSED GAS CYL WHICH
RTECS: 9999999ZZ
IS A VIOLATION OF FED LAW (49CFR). IN PRESENCE OF
RTECS: 9999999ZZ
SILVER, ZINC, & THEIR ALLOYS. IRON OR STEEL ARE
RTECS: 9999999ZZ
AMMONIA (SARA III)
CAS: 7664-41-7
RTECS: BO0875000
Fraction By Weight: 100%
OSHA PEL 50 PPM
ACGIH TLV: 25 PPM/35 STEL; 9293
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
PULM EDEMA(EXCESS FLUID FORM IN LUNGS) WILL
RTECS: 9999999ZZ
LESIONS RSLTING IN TISS DESTRUCT/SCARRING. BURNS
RTECS: 9999999ZZ
PERSONS W/POTNTL EXPOS SHOULD NOT WEAR CONTACT LESNES
RTECS: 9999999ZZ
REMOVE AFFECTED CLOTHING AS RAPIDLY AS POSS. CONTINUE
RTECS: 9999999ZZ
CONTAM CLTHNG/FLUSH AFFECTED AREA W/LUKEWARM WATER.
RTECS: 9999999ZZ
THE CRYOGENIC "BURN" HAS RSLTD IN BLISTERING OF SKIN
RTECS: 9999999ZZ
CLSD, OUTLET SEALS SECURED/VALVE PROT CAP IN PLACE.
RTECS: 9999999ZZ
SLIDE ROLL CYLS. USE SUITABLE
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CORROSIVE & IRRIT TO SKIN, EYES, UPPER
RESP SYS & ALL MUCOSAL TISSUE. DEPENDING ON CONCENTRATION INHALD,
IT MAY CAUSE BURNING SENSATIONS, COUGHING, WHEEZING, SHORTNESS OF
BREATH, HDCH, NAUS, WITH EVEN TUAL COLLAPSE. MILD CONCENTRATIONS OF
VAP WILL CAUSE DERM OR CONJUNCTIVITIS. HIGHER CONCENTRATIONS (SEE
EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:OF VAP OR LIQ CONTACT WILL CAUSE
CAUSTIC SKIN BURNS/INFLAMM/SWELL OF EYES W/POSS LOSS OF VISION.
RAPIDLY EVAPORATING LIQ CONTACTING SKIN OR EYES WILL CAUSE
CRYOGENIC "BURNS" OR FROSTBITE. SYM PS OF FROSTBITE INCL A CHANGE
IN SKIN COLOR TO GRAY/WHITE POSS FOLLOWED BY BLISTERING.
INHAL:AFFECTS UPPER(SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:PROMPT MD ATTEN IS REQ IN ALL CASES OF OVEREXP TO
AMMONIA.INHAL:REMOVE TO UNCONTAM AREA. IF NOT BRTHNG, GIVE ARTF
RESP,PREF MOUTH-TO-MOUTH. IF BRTHNG DFCLT GIVE O*2. KEEP VICTIM
WARM/QUIET. ASSURE THA T MUCUS/VOMIT MATL DOES NOT OBSTRUCT AIRWAY
BY POSITIONAL DRAINAGE. GET MD IMMED. EYE:FLUSH CONTAM EYE(S) W/LGE
QTYS OF WATER FOR AT LEAST 15 MINS. HOLD EYELIDS OPEN TO ASSURE
COMPLETE (SEE INGRED 4)
Fire Fighting
Flash Point:NONE
Lower Limits:16%
Upper Limits:25%
Extinguishing Media:WATER.
Fire Fighting Procedures:IF POSS W/O RISK, STOP FLOW OF GAS. SINCE
AMMONIA IS SOLUBLE IN WATER, IT IS THE BEST EXTING MEDIA-NOT ONLY
EXTING FIRE, BUT ALSO ABSORBING ESCAPED (SUPP DATA)
Unusual Fire/Explosion Hazard:CYL EXPOSED TO FIRE/HEAT MAY VENT
RAPIDLY/EXPLODE. RUNOFF FROM FIRE CONTROL MAY CAUSE POLLUTION.
COMBINES W/MERCURY TO FORM EXPLO CMPDS. IS FLAMM OVER(SUPPDATA)
Accidental Release
Spill Release Procedures:EVACUATE ALL PERSONNEL FROM AFFECTED AREA. USE
APPROPRIATE PROT EQUIP IF LEAK IN USER'S EQUIP, PURGE PIPING
W/INERT GAS PRIOR TO ATTEMPTING REPAIRS. IF LEAK IS IN CNTNR OR
CNTNR VALVE, CALL "800" EMER GENCY PHONE NUMBER LISTED HEREIN.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:USE ONLY IN WELL-VENT AREAS. VALVE
PROT CAPS MUST REAMIN IN PLACE UNLESS CNTNR IS SECURED W/VALVE
OUTLET PIPED TO USE POINT. DO NOT DRAG(SEE INGRED 8)
Other Precautions:EARTH-GROUND & BOND ALL LINES/EQUIP ASSOCIATED
W/AMMONIA SYSTEM. ELEC EQUIP SHOULD BE NON-SPARKING OR EXPLO PROOF.
COMPRESSED GAS CYLINDERS SHOULD NOT BE REFILLED EXCEPT BY QUALIFIED
PRODUCERS OF COMP RESSED GAS. SHIPMENT OF (SEE INGRED 17)
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED POSITIVE PRESSURE AIR LINE
W/MASK OR SCBA SHOULD BE AVAILABLE FOR USE.
Ventilation:HOOD WITH FORCED VENTILATION. LOCAL:TO PREVENT ACCUM ABOVE
TWA. MECH:I/A/W ELECTRICAL CODES.
Protective Gloves:PLASTIC OR RUBBER GLOVES.
Eye Protection:CHEM WORKERS GOG & FULL LGTH FSHLD
Other Protective Equipment:SAFETY SHOES, SAFETY SHOWER, EYEWASH
"FOUNTAIN", CHEMICAL RESISTANT OVERGARMENTS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC:AMMONIA GAS. USE WATER SPRAY TO COOL SURROUND CNTNRS
UNTIL WELL AFTER FIRE IS OUT. USE NIOSH/MSHA SCBA & FULL PROTECTIVE
EQUIP. EFTS OF OVEREXP: AIRWAY (LARYNX/BRONCHI) BY CAUSING CAUS TIC
BURNING RESULTING IN ABNORMAL FLUIDFORMATION/CHEM PNEUMIT (DEEP
LUNG INFLAMM). IF ENTERS THE DEEP LUNG,(SEE ING 2)
Chemical Properties
HCC:G1
Boiling Pt:B.P. Text:-28F,-33C
Vapor Pres:129.1 PSIA
Vapor Density:SEE ING 1
Solubility in Water:VERY SOL/LIBS HEAT
Appearance and Odor:COLORLESS GAS WITH A PUNGENT ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
REACTS VIGOROUSLY W/CHLORINE, FLUORINE, HYDROGEN BROMIDE, NITROSYL
CHLORIDE, CHROMYL CHLORIDE, TRIOXYGEN (SEE INGRED
Stability Condition to Avoid:ANY SYSTEM CONTAINING MERCURY.
Hazardous Decomposition Products:HYDROGEN AT VERY HIGH TEMPERATURES
(1544F).
Disposal
Waste Disposal Methods:ALL FED, STATE & LOCAL REGS REGARDING
HEALTH/POLLUTION SHOULD BE FOLLOWED IN WASTE DISP. CONTACT AIR
PRODS FOR SPECIFIC RECOMMENDATIONS. DO NOT DISP OF UNUSED QTYS.
RETURN PROPERLY LABELED SHIPPING CN TNR TO AIR PRODS FOR DISP
W/VALVE(S) (SEE ING 7)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.