BLGSF - TOPCOATS BRUSH GOODS, 7564

  • MSDS: BLGSF
  • Manufacturer: RUST OLEUM CORP
  • Product Name: TOPCOATS BRUSH GOODS, 7564
  • National Stock Number: 8010-00N019498
Product Identification

Product ID:TOPCOATS BRUSH GOODS, 7564
MSDS Date:07/16/1991
FSC:8010
NIIN:00N019498
MSDS Number: BLGSF

Responsible Party
RUST-OLEUM CORP
11 HAWTHORN PARKWAY
VERNON HILLS, IL 60061

Emergency Phone: 708-367-7700

Info Phone: 708-367-7700

Cage: 08882

Contractor
RUST-OLEUM CORP
VERNON HILLS, IL 60061-1583 US

Telephone: 847-367-7700

Cage: 08882

Ingredients

STODDARD SOLVENT

CAS: 8052-41-3

RTECS: WJ8925000

Fraction By Weight: 40-55%

OSHA PEL 500 PPM

ACGIH TLV: 100 PPM; 9293

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: HARMFUL IF INHALED. MAY
AFFECT BRAIN/NERVOUS SYS CAUSING DIZZ, HDCH OR NAUS. RPTD OVEREXP
MAY PROGRESSIVELY LEAD TO STAGGERING GAIT, CONFUSION, UNCON/COMA.
CAUSES NOSE & THROAT IRRIT. SK IN/EYE: CAUSES SKIN & EYE IRRIT
WHICH CAN LEAD TO DERM W/ RPTD OVEREXP. INGEST: MAY CAUSE GI IRRIT,
(SEE EFTS OF OVEREXP
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: NAUS, VOMIT & DIARRHEA. CHRONIC:
REPORTS HAVE SHOWN RPTD & PRLNGD OCCUPATIONAL OVEREXP TO SOLV
W/PERM BRAIN & NERVOUS SYS DAMAGE.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL: REMOVE FROM EXPOSURE, RESTORE BREATHING & SEE MD. EYE:
FLUSH IMMED W/LARGE AMTS OF WATER FOR AT LEAST 15 MIN. SEE MD.
SKIN: WASH AFFECTED AREA W/SOAP & WATER, REMOVE CONTAMINATED
CLOTHING. WASH BEFORE REUSE. INGEST: DO NOT INDUCE VOMIT. KEEP
WARM & QUIET. GET MD. ASPIRATION OF MATL INTO LUNGS CAN CAUSE CHEM
PNEUM WHICH CAN BE FATAL.

Fire Fighting

Flash Point Method:TCC
Flash Point:104F,40C
Lower Limits:1.0%
Extinguishing Media:NFPA CLASS B EXTINGUISHERS (CARBON DIOXIDE, DRY
CHEMICAL OR FOAM)
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP .
H2O SPRAY MAY BE INEFFECTIVE. H2O MAY BE USED TO COOL CLSD CNTNRS
TO PVNT PRESS BUILDUP & POS (SUPP DATA)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPARKS & OPEN FLAME. CLSD CNTNRS MAY EXPLODE WHEN
EXPOSED TO EXTREME HEAT. DO NOT APPLY TO HOT SURFS.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION, VENT AREA &
REMOVE WITH INERT ABSORBENT & NON-SPARKING TOOLS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 120 F. STORE LRG
QTYS IN BUILDINGS DESIGNED & PROT FOR STORAGE OF NFPA CLASS II
COMBUST LIQ. CNTNRS SHD BE GROUNDED WHEN POURING.
Other Precautions:DO NOT TAKE INTERNALLY. EMPTY CONTAINERS MAY BE
HAZARDOUS.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED CHEMICAL CARTRIDGE
RESPIRATOR (TC23C) TO REMOVE SOLID AIRBORNE PARTICLES OF OVERSPRAY
AND ORGANIC VAPORS DURING SPRAY APPLICATION. IN CONFINED AREAS: USE
NIOSH/MSHA APPROVED SU P-AIR RESPIRATOR OR HOODS (TC19C).
Ventilation:PROVIDE GENRAL DILUTION/LOCAL EXHAUST VENT IN VOL AND
PATTERN TO KEEP TLV OF HAZ INGREDIENTS BELOW ACCEPTABLE LIMITS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:IMPERVIOUS CLOTHING TO PREVENT CONTACT.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC: AUTOIGNITION OR EXPLOSION. IF WATER IS USED, FOG
NOZZLES ARE PREFERRED.

Chemical Properties

HCC:F4
Boiling Pt:B.P. Text:>307F,153C
Vapor Pres:2.0 @ 20 C
Vapor Density:HVR/AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:59-68

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BY OPEN FLAME-CARBON MONOXIDE AND
CARBON DIOXIDE.

Disposal

Waste Disposal Methods:DISPOSE OF ACCORDING TO LOCAL, STATE, AND
FEDERAL REGULATIONS. DO NOT INCINERATE CLOSED CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.