BLNBH - CERAMICAST 4-200 PART A, IC-4200-566000-A
- MSDS: BLNBH
- Manufacturer: PERMAGILE INDUSTRIES INC
- Product Name: CERAMICAST 4-200 PART A, IC-4200-566000-A
- National Stock Number: 8030-00-229-8735
Product Identification
Product ID:CERAMICAST 4-200 PART A, IC-4200-566000-A
MSDS Date:10/03/1990
FSC:8030
NIIN:00-229-8735
Kit Part:Y
MSDS Number: BLNBH
Responsible Party
PLAINVIEW, NY 11803
US
Emergency Phone: 800-424-9300 (CHEMTREC)
Info Phone: 516-349-1100-DAY/800-645-7546-OTHER
Preparer: LAWRENCE T. DEMAIO
Cage: 13549
Contractor
Telephone: 516-349-1100/800-424-9300(CHEMTREC)
Cage: 13549
Ingredients
EPOXY RESIN (VAPOR PRESSURE 0.01 MM HG).EPOXY RESIN MAY
Fraction By Weight: 14-20%
MODIFIED EPOXY RESIN (VAPOR PRESSURE 20.0 MM HG)
Fraction By Weight: 3-7%
ACGIH TLV: 10 MG/M3 / 2 PPM
Hazards
LD50 LC50 Mixture:ORL 11400/5000MG/KG,DERM 17094/2000MG/KG
Effects of Overexposure:VAPORS MAY IRRITATE RESPIRATORY TRACT. CONTACT
IRRITATING TO EYES. MODERATELY IRRITATING TO SKIN. MAY CAUSE SKIN
SENSITIZATION AND OTHER ALLERGIC RESPONSES.
Medical Cond Aggravated by Exposure:MAY AGGRAVATE AN EXISTING
DERMITITIS.
First Aid
First Aid:MOVE TO FRESH AIR.CPR IF NECESSARY.WASH SKIN W/SOAP,WATER OR
WATERLESS HAND CLEANERS.REMOVE CONTAMINATED CLOTHING.DO NOT INDUCE
VOMITING.DRINK LG AMOUNTS WATER IMMEDIATELY.FLUSH EYES W/WATER FOR
15 MI NUTES,GET MED ATTN.DRINK LG AMOUNTS MILK MIXED W/SALT.NEVER
GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON.IF
SWALLOWED,CONTACT PHYSICIAN IMMEDIATELY.IF BREATHING IS
DIFFICULT,OXYGEN MAY BE GIVEN.
Fire Fighting
Flash Point Method:PMCC
Flash Point:207F,97C
Extinguishing Media:WATER FOG, FOAM, CARBON DIOXIDE (CO2), DRY CHEMICAL
AND SAND.
Fire Fighting Procedures:COOL CONTAINERS W/WATER FOG.WEAR PROTECTIVE
CLOTH.FIGHT FIRE FROM SAFE DISTANCE.CLOSE VALVES/SHUT OFF POWER TO
AREA.TURN EMERG LGHTS ON.USE SCBA.UNDER FIRE*
Unusual Fire/Explosion Hazard:N/K *CONDITIONS IRRITATING AND/OR TOXIC
GASES MAY BE PRESENT.COMBUSTION PRODUCTS MAY BE TOXIC.
Accidental Release
Spill Release Procedures:ABSORB W/SAND & DISPOSE IN APPROVED
MANNER.REMOVE SOURCES OF IGNITION.WEAR PROTECT CLOTH.DIKE AREA
W/SAND TO CONTAIN SPILLED LIQ.PREVENT SPILL FROM ENTERING
UNDERGROUND WATER SYSTEMS.VENT AREA.FLUSH A REA W/WATER/DON'T FLUSH
TO SEWER.EMULSIFY REMAIN *
Neutralizing Agent:*MATERIAL WITH SOAP AND WATER AND ABSORB. SCOOP UP
AND PLACE IN DRY DRUMS.
Handling
Handling and Storage Precautions:STORE IN COOL,DRY PLACE. KEEP FROM
OPEN FLAMES. KEEP CLOSED TIGHTLY WHEN NOT IN USE. STORE AWAY FROM
FOOD/BEVERAGES. WASH THOROUGHLY AFTER HANDLING**
Other Precautions:CHECK ALL CONTAINERS FOR LEAKS. AVOID PROLONGED
BREATHING OR CONTACT WITH SKIN.
Exposure Controls
Respiratory Protection:NESA/NIOSH APPROVED RESPIRATOR HIGHLY
RECOMMENDED.SCBA IN CONCENTRATIONS ABOVE PEL/TLV.AVOID BREATH
POSSIBLE FUMES,MIST,VAPOR WHICH CAN CAUSE SEVERE RESPIRATORY
DAMAGE.WORK W/ADEQUATE VENT TO ALLOW DI SSIPATION OF CHEM FUMES &
SOLVENT FUMES.
Ventilation:PROVIDE ADEQUATE CROSS AIR CIRCULATION.
Protective Gloves:RESIST TO CHEM PENETRATN-RUBBER/NEOPRENE
Eye Protection:SPLASHPROOF SAFETY & CHEM WORKER GOGGLES
Other Protective Equipment:EYEWASH STATION.EMERGENCY SHOWER.BARRIER
CREAM RECOMMENDED.CHEM APRON,RUBBER FOOT COVERING,CLEAN LONG SLEEVE
& LEG CLOTH
Work Hygienic Practices:WASH BEFORE EATING, DRINKING, SMOKING OR USING
TOILET.
Supplemental Safety and Health
KEY1:N1. THIS ENTRY DESCRIBES PART A OF A TWO PART KIT. SEE THIS SAME
NSN, P/N IND B AND P/N IND D, FOR PART B DATA.
Chemical Properties
HCC:T6
Spec Gravity:2.1
Evaporation Rate & Reference:SLOWER:N-BUTYL ACETATE
Solubility in Water:NEGLIGIBLE (<0.1%)
Appearance and Odor:BLACK LIQUID, SLIGHT ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, ACIDS, BASES AND/OR CONCENTRATED ALKALI.
MINERAL ACIDS. AMINES.
Hazardous Decomposition Products:OXIDES OF CARBON. ALDEHYDES. TOXIC
MONOMER FUMES AND/OR SHORT CHAIN HYDROCARBONS.
Disposal
Waste Disposal Methods:INCINERATE IN APPROVED MANNER. BURY IN APPROVED
LANDFILL PER GOVERNMENTAL REGULATIONS. DISPOSE OF PER LOCAL
REGULATIONS. IF TRANSPORTATION SPILL, CALL CHEMTREC 800/424-9300.
LARGE SPILL IN CLOSED, NOT SEALED CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.