BLRQL - INTERIOR ODORLESS SEMIGLOSS ENAMEL, SS9-11

  • MSDS: BLRQL
  • Manufacturer: SINCLAIR PAINT CO
  • Product Name: INTERIOR ODORLESS SEMIGLOSS ENAMEL, SS9-11
  • National Stock Number: 8010-00-174-1584
Product Identification

Product ID:INTERIOR ODORLESS SEMIGLOSS ENAMEL, SS9-11
MSDS Date:03/11/1988
FSC:8010
NIIN:00-174-1584
MSDS Number: BLRQL

Responsible Party
SINCLAIR PAINT CO
6100 SOUTH GARFIELD AVE
LOS ANGELES, CA 90040
US

Emergency Phone: 213-664-2121

Info Phone: 213-888-8888

Cage: SNCLA

Contractor
SINCLAIR PAINT CO
LOS ANGELES, CA 90040 US

Telephone: 213-664-2121

Cage: SNCLA

Ingredients

STODDARD SOLVENT

CAS: 8052-41-3

RTECS: WJ8925000

OSHA PEL 500 PPM

ACGIH TLV: 100 PPM; 9293


NAPHTHA, HEAVY ALKYLATE (ALIPHATIC PETROLEUM DISTILLATE).

CAS: 64741-65-7

OSHA PEL 500 PPM (MFR)

ACGIH TLV: 100 PPM (MFR)

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MAY CAUSE EYE, NOSE, THROAT, OR SKIN
IRRITATION. MAY CAUSE HEADACHE, NAUSEA, DIZZINESS, LASSITUDE, OR
LOSS OF COORDINATION OR CONSCIOUSNESS. CHRONIC:NONE RECOGNIZED.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL:REMOVE TO FRESH AIR. GIVE ARTIFICIAL RESPIRATION IF
BREATHING HAS STOPPED. EYE:FLUSH WITH FRESH WATER FOR AT LEAST 15
MINUTES. SKIN:WASH WITH SOAP & WATER. CHANGE CONTAMINATED CLOTHING.
INGEST:D O NOT INDUCE VOMITING. KEEP HEAD LOWER THAN WAIST.
ASPIRATION OF VOMITUS MAY CAUSE CHEMICAL PNEUMONITIS. CALL MD.

Fire Fighting

Flash Point:105F,41C
Lower Limits:SEE INGRED
Extinguishing Media:FOAM, DRY CEHMICAL OR CO2.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. WATER MAY BE UNSIUTABLE AS EXTING MEDIUM, BUT HELPFUL IN COOLING
HOT SURFS/UNRUPTURED CNTNRS. (SUPP DATA)
Unusual Fire/Explosion Hazard:VAPS ARE HEAVIER THAN AIR & MAY
ACCUMULATE IN LOW AREAS OF POOR VENT OR TRAVEL ALONG GROUND TO
REMOTE IGNIT SITES. CLSD CNTNRS CAN BUILD PRESS & MAY (SUPP DATA)

Accidental Release

Spill Release Procedures:REMOVE SOURCES OF HEAT, SPARK OR FLAME. WEAR
APPROPRIATE CLOTHING AND GEAR. CLEAN UP SPILLS IMMEDIATELY WITH
ABSORBENTS SUCH AS CLAY, SAND OR OTHER SUITABLE MATERIALS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP COOL, DRY AND AWAY FROM HEAT,
SPARK OR FLAME (ALL IGNITION SOURCES). STORE IN WELL VENT AREA.
KEEP CONTAINERS CLOSED & UPRIGHT WHEN NOT IN USE.
Other Precautions:AVOID EXCESSIVE PERSONAL EXPOSURE. GROUND & BOND ALL
TRANSFER CNTNRS & EQUIP. DO NOT WELD, DRILL, CUT, OR GRIND FULL,
PARTIAL, OR EVEN EMPTY CNTNRS (RESIDUE AND/OR VAPORS MAY BE
PRESENT). USE W/ADEQ V ENT. AVOID EXCESSIVE VAPOR INHALATION.

Exposure Controls

Respiratory Protection:AVOID EXCESSIVE VAPOR INHALATION. IF PEL OR TLV
IS EXCEEDED, USE NIOSH/MSHA APPROVED RESPIRATOR OR SCBA. USE A
MECHANICAL FILTER TO REMOVE SOLID AIRBORNE PARTICLES DURING SPRAY
APPLICATION.
Ventilation:GEN MECH VENT MAY PROVIDE SUFFICIENT VOLUME/PATTERN TO KEEP
EXPOS BELOW PEL & TLV. EXPLO-PROOF VENT REC FOR FLAMM MATLS.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES, MAY(SUPP DATA)
Other Protective Equipment:EYE WASHES AND SAGETY SHOWERS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC:IF WATER MUST BE USED, USE WATER FOG (NOT A DIRECT
STREAM OF WATER) AS BURNING MATL MAY SPREAD AND/OR FLOAT ON WATER
SURFACE. EXPLO HAZ:EXPLODE WHEN EXPOSED TO EXTREME HEAT. EYE PROT:A
DD FULL LENGTH FACESHIELD TO GOGGLES .

Chemical Properties

HCC:F4
Boiling Pt:B.P. Text:300F,149C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:54-58

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, STRONG ACIDS & BASES, SELECTED AMINES.
Stability Condition to Avoid:HEAT, SPARKS, OR FLAME.
Hazardous Decomposition Products:CO, CO2 & UNIDENTIFIED ORGANIC
COMPOUNDS.

Disposal

Waste Disposal Methods:PLACE IN NON-LEAKING CONTAINERS AND DISPOSE OF
IN ACCORDANCE WITH APPLICABLE LOCAL, COUNTY, STATE, AND FEDERAL
REGULATIONS. BEFORE BEGINNING CLEAN-UP, REFER TO ALL SECTIONS OF
MSDS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.