BLVBP - INHIBISOL

  • MSDS: BLVBP
  • Manufacturer: PENETONE CORP
  • Product Name: INHIBISOL
  • National Stock Number: 6850-00-973-6955
Product Identification

Product ID:INHIBISOL
MSDS Date:05/31/1989
FSC:6850
NIIN:00-973-6955
MSDS Number: BLVBP

Responsible Party
PENETONE CORP
74 HUDSON AVE
TENAFLY, NJ 07670-1017
US

Emergency Phone: 201-567-3000

Info Phone: 201-567-3000

Cage: 56881

Contractor
PENETONE CORP
TENAFLY, NJ 07670 US

Telephone: 201-567-3000

Cage: 56883

Ingredients

METHYL CHLOROFORM (1,1,1-TRICHLOROETHANE)

CAS: 71-55-6

RTECS: KJ2975000

OSHA PEL 350 PPM;450 STEL

ACGIH TLV: 350 PPM;450 STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

LD50 LC50 Mixture:LD50:(ORAL RAT) 10-12 MG/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CHRONIC:OVEREXP HAS CAUSED LIVER TOX
EFTS IN EXPERIMENTAL ANIMALS. ACUTE:EYE:TEMPORARY IRRIT;
SKIN:DEFAT, IRRIT. SIGNS & SYMPS:EYE:TEMPORARY IRRIT. SKIN:DEFAT,
IRRIT. INHAL:DIZZ, DROWS, THROAT IRRIT A T LEVELS ABOVE 1000 PPM.
UNCON & DEATH POSS AT LEVELS ABOVE 10,000 PPM . BLOOD PRESS,
DEPRESS, CARDIAC (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:SENSIT & VENTRICULAR ARRHYTHMIA CAN
RESULT FROM OVEREXP TO NEAR ANESTHETIC LEVEL. CHLOROCARBON MATLS
HAVE PRODUCED SENSIT OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS &
COULD HAVE SIMILAR EFT IN HUMANS. ADRENOMIMETICS (E.G.
EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT FOR LIFE-SUSTAINING USES
IN HUMANS(SUPP DATA)
Medical Cond Aggravated by Exposure:ACUTE CHRONIC LIVER DISEASE AND
RHYTHM DISORDERS OF THE HEART.

First Aid

First Aid:EYE:FLUSH WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES, CALL
MD. SKIN:FLUSH WITH SOAP & WATER. APPLY A GOOD LANOLIN SKIN CREAM.
INHAL:REMOVE TO FRESH AIR. GIVE OXYGEN IF NECESSARY. INGEST:DRINK
LARGE QUANTITIES OF WATER. IF CONSCIOUS, DO NOT INDUCE VOMITING.
GET MD IMMEDIATELY.

Fire Fighting

Flash Point:NONE
Lower Limits:7.5%
Upper Limits:15%
Extinguishing Media:CO*2, DRY CHEMICALS, FOAM TYPE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:COMBUSTION PRODUCTS CONTAIN HYDROGEN
CLHORIDE AND VERY SMALL AMOUTNS OF PHOSGENE AND CHLORINE. THERMAL
DECOMPOSITION PRODUCTS MAY INCLUDE HCL & PHOSGENE .

Accidental Release

Spill Release Procedures:EVACUATE THE AREA VENTILATE & AVOID BRTHG
VAPS. CLEAN UP BY MOPPING OR WITH ABSORBENT MATERIAL & PLACE IN
CLOSED CONTAINERS FOR DISPOSAL. AVOID CONTAMINATION OF GROUND &
SURFACE WATERS. DO NOT FLUSH T O SEWER. IF SPILL OCCURS INDOORS,
TURN (SUPP DATA)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN COOL, DRY, WELL VENTIATED
AREA. PREVENT WATER OR MOIST AIR FROM ENTERING STORAGE TANKS OR
CONTAINERS.
Other Precautions:DO NOT CUT OR WELD ON EMPTY OR FULL DRUMS. ALUMINIM
EQUIP SHOULD NOT BE SUED FOR STORAGE &/OR TRANSFER. VAPORS ARE
HEAVIER THAN AIR & WILL COLLECT IN LOW AREAS. CONTACT W/ALUMINIM
PARTS IN PRESS FLUID SYS MAY CAUSE VIOLENT REACTION.(SUPDAT)

Exposure Controls

Respiratory Protection:WHERE VAPOR CONC EXCEEDS/IS LIKELY TO EXCEED 350
PPM, A NIOSH/MSHA APPROVED ORGANIC VAPOR TYPE RESP IS ACCEPTABLE.
NIOSH/MSHA APPROVED SCBA OR AIR-LINE RESP, FULL FACEPIECE, IS REQ
FOR VAP CONC ABOVE 1,000 PPM & FOR SPILL &/OR EMERGENCIES.
Ventilation:DO NOT USE IN CLOSED OR CONFINED SPACE. OPEN DOORS &/OR
WINDOWS. USE VENTILATEION TO MAINTAIN EXPOS BELOW 350 PPM.
Protective Gloves:SOLVENT RESISTANT GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:SOLVENT RESISTANT BOOTS, GAUNTLETS, APRONS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SPILL PROC:OFF AIR CONDITIONING &/OR HEATING SYS TO PVNT VAPS FROM
CONTAM ENTIRE AREA. OTHER PREC:NO SMOKING IN AREA OF USE. DO NOT
USE IN GEN VICIN OF ARC WELDING, OPEN FLAMES/HOT SURFS. HEAT &/OR
UV RADIA MAY CAUSE FORMATION OF HCL &/OR PHOSGENE. EFTS OF
OVEREXP:ACUTELY/CHRONICALLY EXPOSED TO CHLOROCARBONS .

Chemical Properties

Boiling Pt:B.P. Text:165F,74C
Vapor Pres:100 @ 20C
Vapor Density:4.55
Spec Gravity:1.320
Evaporation Rate & Reference:0.4 (ETHER=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR COLORLESS LIQUID; ETHER LIKE ODOR
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ALKALIES, OXIDIZERS, REACTIVE METALS.
Stability Condition to Avoid:OPEN FLAME, ELECTRIC ARCS, HOT SURFACES.
Hazardous Decomposition Products:HYDORGEN CHLORIDE, SMALL AMOUNT OF
PHOSGENE.

Disposal

Waste Disposal Methods:RECOVER LIQUIDS, MAY BE SENT TO A LICENSED
RECLAIMER OR INCINERATION FACILTIY. CONTAMINATED MATERIAL MUST BE
DISPOSED OF IN A PERMITTED WASTE MANAGEMENT FACILITY. CONSULT
FEDERAL, STATE OR LOCAL EPA P ROCEDURES.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.