BLXYD - LABOR SAVER FLUORESCENT TOPCOATS, 7554

  • MSDS: BLXYD
  • Manufacturer: RUST OLEUM CORP
  • Product Name: LABOR SAVER FLUORESCENT TOPCOATS, 7554
  • National Stock Number: 8010-00N021791
Product Identification

Product ID:LABOR SAVER FLUORESCENT TOPCOATS, 7554
MSDS Date:09/29/1987
FSC:8010
NIIN:00N021791
MSDS Number: BLXYD

Responsible Party
RUST-OLEUM CORP
11 HAWTHORN PKWY
VERNON HILLS, IL 60061
US

Emergency Phone: 312-864-8200

Info Phone: 312-367-7700

Preparer: MJS

Cage: 08882

Contractor
RUST-OLEUM CORP
VERNON HILLS, IL 60061-1583 US

Telephone: 847-367-7700

Cage: 08882

Ingredients

NO INGREDIENT FOR THIS FORMULATION_INGREDIENT

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:ANESTHETIC, IRRIT OF RESP
TRACT OR ACUTE NERV SYS DEPRESS CHARACTERIZED BY HDCH, DIZZ,
STAGGERING, CONFUSION, UNCON OR COMA. SKIN/EYE:PRIMARY IRRIT WHICH
DEFATS SKIN & CAN LEAD TO DERM W/R PTD OVEREXP. INGEST:GI IRRIT,
NAUSEA, VOMIT & DIARR. CHRONIC:REPORTS HAVE SHOWN RPTD/PRLNGD
OCCUPATIONAL(EFTS OF OVEREXP
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:OVEREXP TO SOLVS W/PERM BRAIN & NERV
SYS DMG. OVEREXP TO TOLUENE IN LAB ANIMALS HAS SHOWN LIVER, KIDNEY,
SPLEEN & EYE DMG AS WELL AS ANEMIA. IN HUMANS, OVEREXP HAS BEEN
FOUND TO CAUSE LIVER & CARDIAC ABNORM. OVEREXP TO HEXANE IN HIGH
VAP CONC (1000-1500 PPM) OVER A PERIOD OF SEVERAL MONTHS HAS BEEN
(SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL:REMOVE FROM EXPOSURE, RESTORE BREATHING & CALL MD.
EYE:FLUSH IMMEDIATELY W/LARGE AMOUNTS OF WATER FOR AT LEAST 15
MINUTES. CALL MD. SKIN:WASH AFFECTED AREA WITH SOAP & WATER, REMOVE
CONTAMINATED CLOTHING & WASH BEFORE REUSE. WASH HANDS BEFORE
EATING OR SMOKING. INGEST:DO NOT INDUCE VOMITING. KEEP WARM, QUIET
AND GET MD. ASPIRATION OF MATL INTO LUNGS CAN CAUSE CHEM PNEUMIT
WHICH CAN BE FATAL.

Fire Fighting

Flash Point Method:TCC
Flash Point:<0F,<-18C
Lower Limits:SEE INGRED
Extinguishing Media:NFPA CLASS B EXTINGUISHERS (CARBON DIOXIDE, DRY
CHEMICAL OR FOAM).
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. WATER SPRAY MAY BE INEFTIVE BUT MAY BE USED TO COOL CLSD CNTNRS
TO PVNT PRESS BUILDUP & POSS (SUPP DATA)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPARKS & OPEN FLAME. CLSD CNTNRS MAY EXPLODE WHEN
EXPOSED TO EXTREME HEAT. DO NOT APPLY TO HOT SURFACES

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION, VENTILATE AREA
AND REMOVE WITH INERT ABSORBENT AND NONSPARKING TOOLS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 120F. DO NOT
PUNCTURE.
Other Precautions:INTENTIONAL MISUSE BY DELIBERATELY CONCENTRATING AND
INHALING THE CONTENTS CAN BE HARMFUL OR FATAL.

Exposure Controls

Respiratory Protection:ALL RESPIRATORS MUST BE NIOSH/MSHA APPROVED. USE
CHEMICAL CARTRIDGE RESPIRATOR (TC23C) TO REMOVE SOLID AIRBORNE
PARTICLES OF OVERSPRAY & ORGANIC VAPORS DURING SPRAY APPLIC. IN
CONFINED AREAS USE SUPPL IED-AIR RESPIRATORS OR HOODS (TC19C).
Ventilation:PROVIDE GENERAL DILUTION OR LOCAL EXHAUST VENT IN VOLUME &
PATTERN TO KEEP TLV OF MOST HAZ INGRED BELOW APPLIC LIMIT.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC:AUTOIGNITION OR EXPLOSION. IF WATER USED, FOG NOZ ARE
PREF. EFTS OF OVEREXP:SHOWN TO CAUSE PERIPHERAL POLYNEUROPATHY
WHICH HAS THE POTENTIAL OF BECOMING IRREVERSIBLE.

Chemical Properties

HCC:V3
Boiling Pt:B.P. Text:<0F,<-18C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Evaporation Rate & Reference:SLOWER/ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BY OPEN FLAME-CO, CO2.

Disposal

Waste Disposal Methods:DISPOSE ACCORDING TO LOCAL, STATE, AND FEDERAL
REGULATIONS. DO NOT INCINERATE CLOSED CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.