BMCNB - OMNI-BOND ADHESIVE WITH MIXERS PART A, 4345
- MSDS: BMCNB
- Manufacturer: PREMIER INDUSTRIAL CORP
- Product Name: OMNI-BOND ADHESIVE WITH MIXERS PART A, 4345
- National Stock Number: 8040-00N025501
Product Identification
Product ID:OMNI-BOND ADHESIVE WITH MIXERS PART A, 4345
MSDS Date:09/27/1988
FSC:8040
NIIN:00N025501
Kit Part:Y
MSDS Number: BMCNB
Responsible Party
CLEVELAND, OH 44103
US
Emergency Phone: 216-391-8300
Info Phone: 216-391-8300
Preparer: T.G.
Cage: 18399
Contractor
Telephone: 216-391-8300
Cage: 18399
Ingredients
METHYLENE BISPHENYL; (ISOCYANATE)
CAS: 26447-40-5
Fraction By Weight: <10%
POLYURETHANE POLYMER; (OIL)
CAS: 68424-09-9
Fraction By Weight: >90%
Hazards
LD50 LC50 Mixture:LD50: (ORAL,RAT) >6000 MG/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CONTINUED CONTACT WITH SKIN MAY RESULT
IN SENSITIZATION. CHRONIC VAPORS CAN CAUSE CHEST PAINT AND
SHORTNESS OF BREATH IN RARE INSTANCES.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES: IMMEDIATELY FLUSH WITH PLENTY OF WATER FOR AT LEAST 15
MINUTES AND CALL PHYSICIAN. SKIN: WASH SKIN WITH ISOPROPANOL & THEN
WITH PLENTY OF SOAP AND WATER. INHALATION: IF AFFECTED, REMOVE TO
FRESH AIR, ADMINISTER OXYGEN AND CALL PHYSICIAN. INGESTION: SEEK
PHYSICIAN IMMEDIATELY, SHOW MSDS OR LABEL, DO NOT INDUCE VOMITING.
Fire Fighting
Flash Point:280F,138C
Lower Limits:0.9%
Upper Limits:9.5%
Extinguishing Media:WATER, FOG, FOAM, DRY CHEMICAL, CARBON DIOXIDE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:MOISTURE CONTAMINATION MAY FORM CARBON
DIOXIDE GAS PRESSURE IN CONTAINER.
Accidental Release
Spill Release Procedures:EVACUATE AREA, VENT AREA, WEAR NIOSH/MSHA
APPROVED RESPIRATORY PROTECTION, WEAR SUITABLE PROTECTIVE CLOTHING,
GLOVES, AND EYE/FACE PROTECTION. CLEAN UP WITH ABSORBENT MATERIAL,
CONTAIN AND PICK-UP WAS TE MATERIAL, PUT IN SEALED APPROVED
CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP AWAY FROM HEAT & FLAME. USE ONLY
W/ADEQ VENT. AVOID PRLNGD BRTHG OF VAP/SPRAY MIST. IF VENT IS
INADEQ, WEAR NIOSH/MSHA APPRVD RESP EQUIPMENT.
Other Precautions:AVOID CONT W/EYES & SKIN.DO NOT TAKE INTERNALLY. WASH
THORO AFTER USING. KEEP CNTNRS CLSD WHEN NOT IN USE.IN CASE OF
ACCIDENT/ILLNESS, SEEK PHYS IMMED& SHOW MSDS/LABEL. KEEP OUT OF
REACH OF CHILDREN. ALWAYS READ/FOLLOW DIRECTIONS(SUPP DATA)
Exposure Controls
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN .
Ventilation:LOCAL AND MECHANICAL VENTILATION REQUIRED.
Protective Gloves:SOLVENT RESISTANT GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:WEAR SUITABLE PROTECTIVE CLOTHING.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
OTHER PREC: ON PRODUCT LABEL. ADDITIONAL TECHNICAL DATA SHEETS AND/OR
MATERIAL SAFETY DATA SHEETS (MSDS) ARE AVAILABLE UPON REQUEST. FOR
PROFESSIONAL AND INDUSTRIAL USE ONLY.
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:400F,204C
Vapor Pres:0.00001
Vapor Density:6.0
Spec Gravity:1.04
Evaporation Rate & Reference:NIL
Solubility in Water:NIL
Appearance and Odor:BLACK LIQUID, NO ODOR.
Percent Volatiles by Volume:>0.01
Stability
Stability Indicator/Materials to Avoid:YES
STRONG BASES, WATER, PEROXIDES.
Stability Condition to Avoid:HEAT AND MOISTURE.
Hazardous Decomposition Products:CO, CO*2, AMINES, PYROLYSIS PRODUCTS.
Conditions to Avoid Polymerization:HEAT AND FLAME.
Disposal
Waste Disposal Methods:DISPOSE OF WASTES IN ACCORDANCE WITH FEDERAL,
STATE, AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.