BMPJY - ABA-PLUS

  • MSDS: BMPJY
  • Manufacturer: FEND ALL CO
  • Product Name: ABA-PLUS
  • National Stock Number: 6505-00N025293
Product Identification

Product ID:ABA-PLUS
MSDS Date:06/10/1990
FSC:6505
NIIN:00N025293
MSDS Number: BMPJY

Responsible Party
FEND ALL CO
5 E COLLEGE DR
ARLINGTON HEIGHTS, IL 60004
US

Emergency Phone: 708-577-7400

Info Phone: 708-577-7400

Preparer: JOHN W. BORNHOEFT

Cage: 9S617

Contractor
FENDALL CO
ARLINGTON HEIGHTS, IL 60004 US

Telephone: 800-543-4842

Cage: 9S617

Ingredients

BENZOIC ACID, P-HYDROXY-, METHYL ESTER; (METHYL

CAS: 99-76-3

RTECS: DH2450000

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL: MAY CAUSE MILD IRRITATION IN
SOME SENSITIVE INDIVIDUALS. SKIN: MAY CAUSE IRRIT IN SOME SENSITIVE
INDIVIDUALS. EYE: MAY CAUSE IRRITATION. INGEST: TOXICITY BY
INGESTION IS LOW. METHYL PARABEN IS CONSIDERED GRAS IN THE UNITED
STATES. THE ACCEPTABLE AVERAGE DAILY INTAKE IS 10 MG/KG OF BODY
WEIGHT.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYE:IMMED FLUSH W/H2O FOR @ LST 15 MIN @ CONSULT MD. SKIN:
IMMED FLUSH W/SOAP & H2O, REMOVE CONTAM CLTHG, & CONSULT A
PHYSICIAN. INHAL: MOVE TO FRESH AIR & CONSULT A PHYSICIAN. INGEST:
INGESTION OF LA RGE AMOUNTS OF METHYL PARABEN MAY REQUIRE
CONSULTATION WITH A PHYSICIAN. NOTE TO MD: REMOVAL OF THE SUBSTANCE
FROM CNTCT W/PATIENT SHOULD ALLEVIATE ANY SYMP ASSOCIATED WITH THIS
SUBSTANCE.

Fire Fighting

Extinguishing Media:WATER FOG OR SPRAY, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:NONE, EXCEPT AVOID FUMES. WEAR NIOSH/MSHA
APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:CONC DUST MAY PRESENT DUST EXPLOSION
HAZARD. PREVENT POTENTIAL IGNITION SOURCES. BURNING MAY PRODUCE
IRRIT FUMES THAT REQUIRE PROT EQUIPMENT.

Accidental Release

Spill Release Procedures:SWEEP UP AND REMOVE TO AN APPROPRIATE DISPOSAL
CONTAINER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID EYE & SKIN CONTACT. AVOID
INHALATION AND INGESTION. IN CASE OF HIGH DUST CONC, WEAR A BUREAU
OF MINES APPROVED DUST REGULATOR.
Other Precautions:STORE IN COOL, WELL VENTILATED AREAS. TO PREVENT DUST
ACCUMULATION, CLEAN UP ANY POWDER FROM THE FLOORS, WALLS AND
EQUIPMENT. WEAR PROTECTIVE CLOTHING, GLOVES AND CHEMICAL SPLASH
GOGGLES WHEN A SPILL HAZARD EXISTS.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:518F,270C
Melt/Freeze Pt:M.P/F.P Text:257F,125C
Spec Gravity:1.36 @ 75 F
Solubility in Water:0.25 %
Appearance and Odor:WHITE POWDER WITH LITTLE OR NO ODOR.
Percent Volatiles by Volume:NEGLIG

Stability

Stability Indicator/Materials to Avoid:YES
CONTACT WITH STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:AVOID CREATING DUST. CONC DUST MAY PRESENT
AN EXPLOSION HAZARD.
Hazardous Decomposition Products:POSSIBLE COMBUSTION PRODUCTS MAY
INCLUDE CARBON MONOXIDE (CO) AND PHENOLIC VAPORS.

Disposal

Waste Disposal Methods:DISPOSE OF THE MATERIAL IN ACCORDANCE WITH
LOCAL, STATE AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.