BMVST - 200 SYSTEM KNIGHT/LAGGI TAPE-PRIMER-CEMENT

  • MSDS: BMVST
  • Manufacturer: RUSTOL CHEMICALS CO LTD
  • Product Name: 200 SYSTEM KNIGHT/LAGGI TAPE-PRIMER-CEMENT
  • National Stock Number: 8030-00N029239
Product Identification

Product ID:200 SYSTEM KNIGHT/LAGGI TAPE-PRIMER-CEMENT
MSDS Date:11/06/1989
FSC:8030
NIIN:00N029239
MSDS Number: BMVST

Responsible Party
RUSTOL CHEMICALS CO LTD
TACHIBANA BLDG 9-12 KYOBASHI
2-CHOME, CHUO-KU, TOKYO JAPAN 104

Emergency Phone: 415-956-4097

Info Phone: 415-956-4097

Cage: RUSTO

Contractor
RUSTOL CHEMICALS CO LTD
2-CHOME, CHUO-KU, TOKYO JAPAN 104 US

Telephone: 415-956-4097

Cage: RUSTO

Ingredients

CYCLOHEXANONE (SARA III)

CAS: 108-94-1

RTECS: GW1050000

OSHA PEL S, 50 PPM

ACGIH TLV: S, 25 PPM; 9293

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


CHROMIC ACID, ZINC SALT; (ZINC CHROMATE)

CAS: 13530-65-9

RTECS: GB3290000

OSHA PEL 0.1 MG/M3 (CRO3)

ACGIH TLV: 0.01 MG/M3 (CR)

Hazards

LD50 LC50 Mixture:LD50: (ORAL,RAT) > 5 G/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:EYE: IRRITATING TO EYES. REDDENING CAN
OCCUR WITHIN ONE HOUR. PERSONS HAVING EYE CONTACT CAN EXPECT
TRANSIENT IRRITATION, NOT PERMANENT DAMAGE. SKIN: READILY ABSORBED
THROUGH SKIN. PROLONGED SKIN CONT ACT MAY RESULT IN IRRITATION AND
DERMATITIS. INHALATION: VAPORS MAY CAUSE IRRITATION OF RESPIRATORY
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:ZINC CHROMATE: GROUP 1(NTP, IARC).
Effects of Overexposure:HLTH HAZ: SYSTEM AND NERVOUS SYSTEM IMPAIRMENT.
INGEST: CEMENT AND PRIMER ARE SLIGHTLY TOX UPON INGEST. PROLONGED
BREATHING OF VAPORS, SKIN CONTACT, OR INGESTION MAY CAUSE
IRRITATION. SYMPTOMS OF OVER EXPOSURE MAY INCLUDE DIZZINESS,
NAUSEA,HEADACHE, VOMITING, UNCOORDINATION, CONFUSION, DROWSINESS,
AND UNCONSCIOUSNESS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. CONSULT
PHYSICIAN. SKIN: USE HAND CLEANER AND FOLLOW WITH GOOD WASHING WITH
SOAP & WATER. INHALATION: REMOVE TO FRESH AIR. INGESTION: CONSULT
PHYSICIAN IMMEDIATELY.

Fire Fighting

Flash Point:97.0F,36.1C
Lower Limits:0.9%
Upper Limits:7.0%
Extinguishing Media:WATER, FOAM, CO2, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE KNOWN.

Accidental Release

Spill Release Procedures:COLLECT SPILLED MATL USING ABSORB & PLACE IN
DOT APPRVD CNTNR FOR SHIPMENT. PROPER SHIPPING NAME TO BE USED IS
"HAZ WASTE SOLID ORM E". BE SURE CONTENTS ARE SOLID BY USING
SUFFICIENT ABSORB. LIQ SHOUL D NOT EXCEED 20% OF TOTAL VOLUME.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPARKS, AND OPEN
FLAMES. AVOID EYE CONTACT. AVOID PROLONGED BREATHING OF VAPORS.
Other Precautions:USE ONLY IN WELL VENT AREAS W/SUFF AIR MOVEMENT TO
MAINTAIN VAP LEVS AT RECOGNIZED HEALTH AND SAFETY LEVELS. KEEP
CONTAINERS CLOSED WHEN NOT IN USE. GLYCOL ETHERS MAY BE
REPRODUCTIVE TOXICANTS. AVOID USE OF PRODS DURING PREGNANCY.

Exposure Controls

Respiratory Protection:IN CONFINED ARES OF POORLY VENTILATED AREAS, USE
NIOSH/MSHA APPROVED HALF MASK RESPIRATOR EQUIPPED WITH ORGANIC
VAPOR CARTRIDGES.
Ventilation:USE OUTDOORS OR IN WELL VENTILATED AREAS. LOCAL EXHAUST
SHOULD BE GREATER THAN 60 FPM.
Protective Gloves:RUBBER GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

HCC:F4
Vapor Pres:<20
Vapor Density:3.8
Spec Gravity:1.6
Evaporation Rate & Reference:<0.6 (BUOAC=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:ESTER/SOLVENT ODOR.
Percent Volatiles by Volume:30

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS.
Stability Condition to Avoid:SPARKS, OPEN FLAME.
Hazardous Decomposition Products:CO, ALDEHYDES, NOXIOUS FUMES.

Disposal

Waste Disposal Methods:KNIGHT/LAGGI SYS MUST BE DISP OF AS RCRA HAZ
WASTE EPA HAZ WASTE NUMBER D001. UNUSED MATL CAN BE DISPOSED OF IN
SIMILAR MANNER OR INCINERATED AT PERMITTED HAZ WASTE FACILITY.
DISPOSE OF I/A/W LOCAL, S TATE & FEDERAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.