BMWPN - 348

Product Identification

Product ID:348
MSDS Date:10/21/1991
FSC:8010
NIIN:00-079-3756
MSDS Number: BMWPN

Responsible Party
ILLINOIS BRONZE PAINT COMPANY
300 EAST MAIN STREET
LAKE ZURICH, IL 60047-2580
US

Emergency Phone: 800-228-5635

Info Phone: 312-488-8001

Cage: 91794

Contractor
ILLINOIS BRONZE PAINT COMPANY
LAKE ZURICH, IL 60047-2580 US

Telephone: 800-228-5635

Cage: 91794

Ingredients

TITANIUM DIOXIDE

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: <5%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


XYLENES (O-,M-,P- ISOMERS) (SARA III)

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 5 - 10%

OSHA PEL 100 PPM/150 STEL

ACGIH TLV: 100 PPM/150STEL;9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


TOLUENE (SARA III)

CAS: 108-88-3

RTECS: XS5250000

Fraction By Weight: 15 - 20%

OSHA PEL 200 PPM/150 STEL

ACGIH TLV: 50 PPM; 9293

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ACETONE (SARA III)

CAS: 67-64-1

RTECS: AL3150000

Fraction By Weight: 35 - 40%

OSHA PEL 1000PPM

ACGIH TLV: 750PPM/1000STEL;9293

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ETHYL-3-ETHOXYPROPIONATE

CAS: 763-69-9

RTECS: UF3325000

Fraction By Weight: <5%


ISOBUTANE

CAS: 75-28-5

RTECS: TZ4300000

Fraction By Weight: 15%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM


PROPANE

CAS: 74-98-6

RTECS: TX2275000

Fraction By Weight: 15%

OSHA PEL 1000 PPM

ACGIH TLV: ASPHYXIANT; 9192

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:IN CONFINED AREA VAPORS IN A HIGH
CONCENTRATION ARE ANESTHIC
Effects of Overexposure:INHALATION; ANESTHETIC, IRRITITANT TO SKIN AND
UPPER RESPIRATORY SYSTEM, LIGHT JEADNESS, STAGGERING
QUAIT,GIDDEINESS AND POSSIBLE NAUSEA.
Medical Cond Aggravated by Exposure:NONE

First Aid

First Aid:INHALATION;REMOVE TO FRESH AIR. EYES;FLUSH WITH WATER FOR AT
LEAST 15 MINUTES. SKIN;WASH WITH SOAP AND WATER. INGESTION;CALL
PHYSCIAN IMMEDIATELY,DO NOT INDUCE VOMITING.

Fire Fighting

Flash Point Method:TCC
Flash Point:<20F,<-7CPROPELL
Lower Limits:NA
Upper Limits:NA
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL OR FOAM.
Fire Fighting Procedures:WATER MAY BE INEFFECTIVE-WATER MAY BE USED TO
KEEP FIRE EXPOSED CONTAINERS COOL.
Unusual Fire/Explosion Hazard:DO NOT SPRAY NEAR FLAME, KEEP AT ROOM
TEMPERATURE AS EXPOSURE TO DIRECT SUNLIGH OR OTHER HEATING MAY
CAUSE BURSTING.

Accidental Release

Spill Release Procedures:REMOVE ALL IGNITION SOURCES, VENTILATE ,AVOID
BREATHING VAPORS AND REMOVE WITH AN INERT COMPOUND.
Neutralizing Agent:NA

Handling

Handling and Storage Precautions:DO NOT STORE ABOVE 120F,EXPOSURE TO
DIRECT SUNLIGH MAY CAUSE CAN TO BURST.
Other Precautions:KEEP AWAY FROM CHILDREN,DO NOT PUNCTURE OR
INCINERATE. DO NOT SPRAY NEAR FIRE OR OPEN FLAME.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED ORGANIC VAPOR RESPIRATOR
IF TLV LEVELS ARE EXCEEDED.
Ventilation:LOCAL,TO KEEP BELOW ESTABLISHED LEVELS.
Protective Gloves:FOR REPEATED OR PROLONG CONTACT.
Eye Protection:YES WITH UNPERFORATED SIDE SHIELD.
Other Protective Equipment:NA
Work Hygienic Practices:PRUDENT
Supplemental Safety and Health
NONE

Chemical Properties

HCC:V3
Boiling Pt:B.P. Text:<0F,<-18C
Melt/Freeze Pt:M.P/F.P Text:NA
Vapor Pres:NA
Vapor Density:>AIR
Spec Gravity:NA
Evaporation Rate & Reference:>ETHER
Solubility in Water:NA
Appearance and Odor:BLACK COATING
Percent Volatiles by Volume:8887

Stability

Stability Indicator/Materials to Avoid:YES
NONE
Stability Condition to Avoid:DO NOT STORE ABOVE 120F
Hazardous Decomposition Products:CARBON MONOXIDE/ CARBON DIOXIDE
Conditions to Avoid Polymerization:HEAT OPEN FLAMES.

Disposal

Waste Disposal Methods:DO NOT INCINERATE, DISPOSE IN ACCORDANCE WITH
LOCAL,STATE AND FEDERAL REGULATION.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.