BMWRF - 30372
- MSDS: BMWRF
- Manufacturer: SHERWIN WILLIAMS CO
- Product Name: 30372
- National Stock Number: 8010-00-251-3661
Product Identification
Product ID:30372
MSDS Date:07/25/1988
FSC:8010
NIIN:00-251-3661
MSDS Number: BMWRF
Responsible Party
CLEVELAND, OH 44115-1042
US
Emergency Phone: 216-566-2917
Info Phone: 216-566-2902
Cage: 54636
Contractor
Telephone: 800-251-2486/216-566-2242
Cage: 54636
Ingredients
HYDROTREATED HEAVY NAPHTHA
CAS: 64742-48-9
Fraction By Weight: 0-5%
HYDROTREATED LIGHT PETROLEUM DISTILLATE
CAS: 64742-47-8
Fraction By Weight: 35-55%
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM
NAPHTHA, MEDIUM ALIPHATIC
CAS: 64742-88-7
Fraction By Weight: 0-5%
DIPROPYLENE GLYCOL METHYL ETHER
CAS: 34590-94-8
RTECS: JM1575000
Fraction By Weight: 0-5%
OSHA PEL S,100PPM/150STEL
ACGIH TLV: S,100PPM/150STEL9192
PROPYLENE GLYCOL MONOMETHYL ETHER ACETATE
CAS: 108-65-6
RTECS: AI8295000
Fraction By Weight: 0-5%
OSHA PEL 100 PPM
ACGIH TLV: 100 PPN
TALC (CONTAINING ASBESTOS)
CAS: 14807-96-6
RTECS: MW2700000
Fraction By Weight: 0-15%
OSHA PEL 0.2 FIBERS/CC
ACGIH TLV: 0.2 FIBERS/CC; 9192
TITANIUM DIOXIDE
CAS: 13463-67-7
RTECS: XR2275000
Fraction By Weight: 0-30%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST; 9293
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:UNKNOWN OSHA:NO
Health Hazards Acute and Chronic:IRRITATION OF EYES,SKIN AND
RESPIRATORY SYSTEM.MAY CAUSE NERVOUS SYSTEM DEPRESSION,
Effects of Overexposure:HEADACHE,DIZZINESS, NAUSEA, LOSS OF
COORDINATION, REDDINESS AND BURNING OR ITCHING. UNCONSCIOUNESS OR
DEATH.
Medical Cond Aggravated by Exposure:NONE RECOGNIZED
First Aid
First Aid:INHALATION;LEAVE THE AREA,GET FRESH AIR,IF PROBLEMS ARISE
LATER GET MEDICAL ATTENTION.SKIN;WASH WITH SOAP AND WATER,REMOVE
CONTAMINATED CLOTHING AND WASH BEFORE REUSE. EYES;FLUSH WITH LARGE
AMOUNTS OF WATER FOR 15MINUTESGET MEDICAL ATTENTION. INGESTION;
GET MEDICAL ATTENTION
Fire Fighting
Flash Point Method:PMCC
Flash Point:102F,39C
Lower Limits:0.9
Upper Limits:NOT GIVEN
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM
Fire Fighting Procedures:FULL PROTECTIVE EQUIPMENT INCLUDING SCBA,WATER
SPRAY MAY BE INEFFECTIVE. IF WATER IS USED FOG NOZZLES ARE
PREFERRED. WATER MAY BE USED TO COOL CONTAINERS.
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY EXPLODE WHEN
EXPOSED TO EXYTREME HEAT,APPLICATION TO HOT SURFACE REQUIRE SPECIAL
PRECAUTIONS. OVEREXPOSURE TO PRODUCT MAY CAUSE HEALTHPROB
Accidental Release
Spill Release Procedures:REMOVE ALL IGNITION SOURCES, VENTILATE AREA,
COVER SPILL WITH ABSORBENT MATERIAL,
Neutralizing Agent:NA
Handling
Handling and Storage Precautions:KEEP AWAY FROM OPEN FLAMES AND EXTREME
HEAT. KEEP CONTAINERS CLOSED WHEN NOT IN USE,DO NOT TAKE
INTERNALLY,KEEP OUT OF REACH OF CHILDREN
Other Precautions:READ AND FOLLOW WARNING LABEL OF ALL PRODUCTS,
INTENTIONAL MISUSE BY DELIBERATLY CONCENTRATING AND INHALING CAN BE
HARMFUL AND OR FATAL.
Exposure Controls
Respiratory Protection:WHERE OVERSPRAY IS PRESENT A POSITIVE PRESSURE
AIR SUPPLY RESPIRATOR SHOULD BE WORN.
Ventilation:LOCAL AND MECHANICAL TO KEEP LEVELS BELOW TVL
Protective Gloves:AS SUGGESTED BY GLOVE SUPPLIER
Eye Protection:SPECTACLES WITH PERFORATED SIDESHIELDS.
Other Protective Equipment:USE BARRIER CREAMS ON EXPOSED SKIN.
Work Hygienic Practices:PRUDENT
Supplemental Safety and Health
NA
Chemical Properties
HCC:F4
Boiling Pt:B.P. Text:240F,116C
Vapor Pres:NOT GIVEN
Vapor Density:>AIR
Spec Gravity:NOT GIVEN
Evaporation Rate & Reference:
Appearance and Odor:NOT GIVEN
Stability
Stability Indicator/Materials to Avoid:YES
WATER,ALCHOL, AMINES.
Stability Condition to Avoid:NONE GIVEN
Hazardous Decomposition Products:BY FIRE, CARBON DIOXIDE,CARBON
MONOXIDE
Disposal
Waste Disposal Methods:INCINERATE IN APPROVED FACILITY, DO NOT
INCINERATE IN CLOSED CONTAINERS. DISPOSE OF IN ACCORDANCE WITH
LOCAL, STATE AND FEDERAL GUIDLINES.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.