BMXCC - U-1000

Product Identification

Product ID:U-1000
MSDS Date:12/01/1989
FSC:8010
NIIN:01-201-7657
MSDS Number: BMXCC

Responsible Party
STERLING LACQUER MFG. CO. INC.
3150 BRANNON AVE
ST. LOUIS, MO 63139
US

Emergency Phone: 314-776-4450

Info Phone: 314-776-4450

Cage: 60003

Contractor
STERLING LACQUER MFG CO
ST. LOUIS, MO 63139-1422 US

Telephone: 314-776-4450

Cage: 60003

Ingredients

HOMOPOLYMER OF HEXAMETHYLENE DIISOCYANATE (HDI)

CAS: 28182-81-2

RTECS: NQ9170000

Fraction By Weight: 30%


ETHYL ACETATE (SARA III)

CAS: 141-78-6

RTECS: AH5425000

Fraction By Weight: 15%

OSHA PEL 400 PPM

ACGIH TLV: 400 PPM; 9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


PROPYLENE GLYCOL MONOMETHYL ETHER ACETATE

CAS: 108-65-6

RTECS: AI8295000

Fraction By Weight: 30%

OSHA PEL 100 PPM

ACGIH TLV: 100 PPN


N-BUTYL ACETATE (SARA III)

CAS: 123-86-4

RTECS: AF7350000

Fraction By Weight: 10%

OSHA PEL 150 PPM/200 STEL

ACGIH TLV: 150 PPM/200STEL;9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


XYLENES (O-,M-,P- ISOMERS) (SARA III)

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 5 - 10%

OSHA PEL 100 PPM/150 STEL

ACGIH TLV: 100 PPM/150STEL;9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INHALATION;IRRITATION TO RESPIRATORY
TRACT OR NARCOSIS. SKIN/EYES;IRRITATING, MAY INJUR EYE TISSUE IF
NOT PROPERLY REMOVED. INGESTION; MODERATELY TOXIC; MAY CAUSE
NASEAU, VOMITING, AND DIARREHA.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:RESPIRATORY PROBLEMS.

First Aid

First Aid:EYES; FLUSH WITH WATER FOR 15 MINUTES, GET MEDICAL ATTENTION.
SKIN; REMOVE CONTAMINATED CLOTHING, WASH AFFECTED AREA WIYH SOAP
AND WATER. INHALATION; REMOVE TO FRESH AIR, OBTAIN MEDICAL
ATTENTION IF N EEDED. INGESTION; DO NOT INDUCE VOMITING, GET
IMMEDIATE MEDICAL ATTENTION.

Fire Fighting

Flash Point Method:TCC
Flash Point:24.0F,-4.4C
Lower Limits:1.1
Upper Limits:13.1
Extinguishing Media:FOAM, CO2, DRY CHEMICALS
Fire Fighting Procedures:WEAR SCBA OPERATED IN POSITIVE PRESSURE MODE,
USE WATER FOG NOZZLE TO COOL CLOSED CONTAINERS.
Unusual Fire/Explosion Hazard:DO NOT USE WATER,FLAMMABLE LIQUID, CAN
RELEASE VAPORS THAT FORM FLAMMABLE MIXTURES AT TEMPERATURES AT OR
ABOVE FLASH POINT. ISOLATE ALL IGNITION SOURCES.

Accidental Release

Spill Release Procedures:ABSORB WITH VERMICULITE OR OTHER ABSORBENT
MATERIAL,ELIMINATE ALL IGNITION SOURCES, STOP SPILL AT SOURCE AND
PREVENT SPREADING.
Neutralizing Agent:NA

Handling

Handling and Storage Precautions:STORE IN DRY AREA, KEEP CONTAINERSS
TIGHTLY CLOSED.PROTECT FROM PHYSCIAL DAMAGE, STORE BELOW 120F. ALL
MSDS REQUIREMENTSMUST BE ADHERED TO.
Other Precautions:STORE LARGE QUANTITIES IN BUILDINGS DESIGNED TO
COMPLY WITH OSHA1910.106. KEEP CONTAINERS UPRIGHT TO PREVENT
SPILLS, DO NOT STORE NEAR HEAT,SPARKS OR OPEN FLAMES, KEEP AWAY
FROM CHILDREN. AVOID SKIN C ONTACT DO NOT TAKE INTERNALLY

Exposure Controls

Respiratory Protection:IF TLV ARE EXCEEDED A NIOSH/MSHA APPROVED AIR
SUPPLY RESPIRATOR IS ADVISED. ENGINEER OR ADMINISTRATIVE CONTROLS
SHOULD BE IMPLEMENTED.
Ventilation:SUFFICENT TO KEEP BELOW TLV LEVELS.
Protective Gloves:SOLVENT RESISTANT
Eye Protection:CHEMICAL SPLASH GOGGLES.
Other Protective Equipment:TO PREVENT PROLONGED OR REPEATED CONTACT.
WEAR IMPERVOUS CLOTHING AND BOOTS.
Work Hygienic Practices:WASH WITH SOAP AND WATER BEFORE EATINH OR
SMOKING.
Supplemental Safety and Health
NONE

Chemical Properties

HCC:F2
Boiling Pt:B.P. Text:>167F,>75C
Vapor Pres:NOT GIVEN
Vapor Density:> AIR
Spec Gravity:1.0
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:NEGIBLE
Appearance and Odor:LIQUID, SOLVENT ODOR

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:AVOID EXCESSIVE HEAT
Hazardous Decomposition Products:CARBON DIOXIDE/CARBON MONOXIDE.

Disposal

Waste Disposal Methods:DESTROY BY LIQUID INCINERATION, CONTAMINATED
ABSORBENT MAY BE DEPOSITED IN A SANITARY LANDFILL INACCORDANCE WITH
LOCAL,STATE AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.