BNDYR - 15066 CHROMIUM STANDARD DISSOLVED IN OIL
- MSDS: BNDYR
- Manufacturer: EM SCIENCE A DIV OF EM INDUSTRIES
- Product Name: 15066 CHROMIUM STANDARD DISSOLVED IN OIL
- National Stock Number: 6850-00F022254
Product Identification
Product ID:15066 CHROMIUM STANDARD DISSOLVED IN OIL
MSDS Date:08/15/1988
FSC:6850
NIIN:00F022254
MSDS Number: BNDYR
Responsible Party
GIBBSTOWN, NJ 08027
Emergency Phone: 609 354-9200
Info Phone: 609 354-9200
Cage: FO814
Contractor
Telephone: 856-423-6300
Cage: FO814
Ingredients
CHROMIUM METAL, CHROMIUM, CHROME (SUSPECTED A1 HUMAN
CAS: 7440-47-3
RTECS: GB4200000
OSHA PEL 1 MG/CUM
ACGIH TLV: 0.5 MG/CUM
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
MINERAL OIL; PETROLATUM-LIQUID; WHITE MINERAL OIL, PARAFFIN
CAS: 8012-95-1
RTECS: PY8030000
OSHA PEL 5 MG/CUM
ACGIH TLV: 5 MG/CUM
Hazards
Routes of Entry: Inhalation:NO Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:INGESTION: IRRITATION.
Explanation of Carcinogenicity:CHROMIUM IS A SUSPECTED A1 HUMAN
CARCINOGEN BY NTP, IARC & ICGIH.
First Aid
First Aid:SKIN: WASH THOROUGHLY W/SOAP & WATER. EYES: FLUSH THOROUGHLY
W/WATER FOR AT LEAST 15 MINS. INHALATION: REMOVE TO FRESH AIR; GIVE
ARTIFICIAL RESPIRATION IF BREATHING HAS STOPPED. INGESTION: IF
CONSCIO US, INDUCE VOMITING. OBTAIN MEDICAL ATTENTION IN ALL CASES.
Fire Fighting
Flash Point:145F
Extinguishing Media:WATER SPRAY, FOAM, DRY CHEMICAL, OR CO2.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:MODERATE FIRE HAZARD. COMBUSTIBLE LIQUID.
Accidental Release
Spill Release Procedures:DIKE SPILL, TAKE UP W/ABSORBENT & CONTAINERIZE
FOR PROPER DISPOSAL.
Handling
Handling and Storage Precautions:KEEP CONTAINER CLOSED. STORE IN A
COOL, DRY AREA AWAY FROM IGNITION SOURCES. DON'T BREATHE VAPOR OR
SOLUTION MIST. DON'T TAKE INTERNALLY.
Other Precautions:DON'T GET IN EYES, ON SKIN, OR ON CLOTHING. WASH
THOROUGHLY AFTER HANDLING. COMBUSTIBLE LIQUID.
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR SHOULD BE WORN IN
THE ABSENCE OF ADEQUATE VENTILATION.
Ventilation:MATERIAL SHOULD BE HANDLED OR TRANSFERED IN AN APPROVED
FUME HOOD OR W/ADEQUATE VENTILATION.
Protective Gloves:NEOPRENE OR EQUIVALENT
Eye Protection:SAFETY GLASSES W/SIDE SHIELDS
Other Protective Equipment:IMPERVIOUS PROTECTIVE CLOTHING, EYE WASH
Supplemental Safety and Health
Chemical Properties
Solubility in Water:INSOLUBLE
Appearance and Odor:COLORLESS LIQUID
Stability
Stability Indicator/Materials to Avoid:YES
OXIDIZERS
Stability Condition to Avoid:HEAT, IGNITION SOURCES
Disposal
Waste Disposal Methods:TO BE PERFORMED IN COMPLIANCE W/ALL CURRENT
LOCAL, STATE & FEDERAL REGULATIONS. COMBUSTIBLE LIQUID, NA1993
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.