BNKYP - LECTRA-MOTIVE CLEANER, 765-1313

  • MSDS: BNKYP
  • Manufacturer: CRC CHEMICALS
  • Product Name: LECTRA-MOTIVE CLEANER, 765-1313
  • National Stock Number: 6850-00N026445
Product Identification

Product ID:LECTRA-MOTIVE CLEANER, 765-1313
MSDS Date:07/01/1986
FSC:6850
NIIN:00N026445
MSDS Number: BNKYP

Responsible Party
CRC CHEMICALS
885 LOUIS DR
WARMINSTER, PA 18974
US

Emergency Phone: 215-674-4300

Info Phone: 215-674-4300

Cage: CRCCE

Contractor
CRC INDUSTRIES, INC.
WARMINSTER, PA 18974-2820 US

Telephone: 215-674-4300/800-424-9300

Cage: 10136

Ingredients

ETHANE, 1,1,1-TRICHLORO-; (1,1,1-TRICHLOROETHANE)

CAS: 71-55-6

RTECS: KJ2975000

Fraction By Weight: 72%

OSHA PEL 350 PPM;450 PPM STEL

ACGIH TLV: 350 PPM;450 PPM STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


ETHYLENE, TETRACHLORO-; (PERCHLOROETHYLENE)

CAS: 127-18-4

RTECS: KX3850000

Fraction By Weight: 24%

OSHA PEL 100 PPM

ACGIH TLV: 25PPM/100,A3 STEL;94

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


CARBON DIOXIDE

CAS: 124-38-9

RTECS: FF6400000

Fraction By Weight: 4%

OSHA PEL 5000 PPM

ACGIH TLV: 5000PPM/30000STEL;93


OF HCL &/OR PHOSGENE. MAY DISPLACE O*2 IN

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE - INHAL: HEADACHES, DIZZINESS,
ANESTHESIA, UNCONSCIOUSNESS. EYES: CAUSES PAIN AND SOME IRRITATION.
SKIN: CAUSES IRRITATION ON REPEATED EXPOSURES. CHRONIC - REPEATED
OVEREXPOSURES MAY CAUSE LIVER AND KIDNEY EFFECTS. CHLOROCARBON
MATLSHAVE PRDCED SENSITIZATION OF MYOCARDIUM TO EPINEPHRINE IN LAB
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:TETRACHLORETHYLENE IARC GROUP 2B;
ANTICIPATED TO BE A CARCINOGEN.(NTP).
Effects of Overexposure:HLTH HAZ: ANIMALS AND MAY HAVE A SIMILAR EFFECT
IN HUMANS. ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE
CONTRAINDICATED EXCEPT FOR LIFE-SUSTAINING USES IN HUMANS ACUTELY
OR CHRONICALLY EXPOSED TO CHLOROC ARBONS .
Medical Cond Aggravated by Exposure:HIGH LEVELS (8000 PPM +) OF VAPOR
MAY CAUSE CARDIAC ARRTHYMIAS.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR, APPLY ARTIFICIAL RESPIRATION IF
NECESSARY. IF SYMPTOMS PERSIST, CALL MD. EYES: FLUSH FOR A MINIMUM
OF 15 MIN W/LARGE AMOUNTS OF WATER. IF SYMPTOMS PERSIST, CALL MD.
SKIN: R EMOVE CONTAMINATED CLOTHING. WASH EXPOSED SKIN W/SOAP. IF
SYMPTOMS PERSIST, CALL MD. INGEST: DO NOT INDUCE VOMITING. IF
SYMPTOMS PERSIST, CALL MD.

Fire Fighting

Flash Point:NONE
Lower Limits:7.5%
Upper Limits:14.5%
Extinguishing Media:WATER FOG.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
& FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:AEROSOLS MAY EXPLODE IF THEIR TEMPERATURE
EXCEEDS 130F. THERMAL DECOMPOSITION PRODUCTS MAY INCLUDE HCL AND
PHOSGENE .

Accidental Release

Spill Release Procedures:USUALLY NOT A PROBLEM WITH AEROSOLS. AREA
SHOULD BE VENTILATED AND ABSORBENT USED TO PICK UP EXCESS MATERIAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN A COOL DRY AREA.
Other Precautions:AVOID PRLNG SKIN CONT/BRTHG VAPS. SINCE VAPS ARE
HEAVIER THAN AIR, AEROSOLS SHLD NOT BE USED IN CONFINED AREAS OR
LOW SPOTS W/O ADEQ VENT. IF VAPS ARE SUSPECTED IN LOW AREA, DO NOT
ENTER UNLESS SPECIA L BRTHG APPARATUS IS USED (SUPP DATA)

Exposure Controls

Respiratory Protection:ABOVE TLV, USE NIOSH/MSHA APPROVED
SELF-CONTAINED AIR MASK OR VAPOR MASK.
Ventilation:LOCAL EXHAUST TO MAINTAIN VAPOR CONCENTRATION BELOW TLV.
USE MECHANICAL (GENERAL) MEANS IF NECESSARY.
Protective Gloves:SOLVENT RESISTANT GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NOT NORMALLY REQUIRED FOR AEROSOL PRODUCTS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SOL IN H*2O: SLIGHT SOLUBILITY IN H*2O. GOOD SOLVENT FOR MANY ORGANIC
MATLS. FL PT METH: TCC, TOC, COC. OTHER PREC: AND AN OBSERVER IS
PRESENT FOR ASSISTANCE. KEEP AEROSOLS AWAY FROM HEAT. NO SMKG IN
AREA OF USE. DO NOT USE IN GEN VICIN OFARC WELDING/OPEN FLAMES/HOT
SURF. HEAT &/OR UV RADIA MAY CAUSE FORMATION (ING 4)

Chemical Properties

Boiling Pt:B.P. Text:>165F,>74C
Vapor Pres:85
Vapor Density:4.8
Spec Gravity:1.385
Evaporation Rate & Reference:RAPID (BUTYL ACETATE = 1)
Solubility in Water:SEE SUPP DATA
Appearance and Odor:COLORLESS LIQUID - IRRITATING ODOR AT HIGH CONC.

Stability

Stability Indicator/Materials to Avoid:YES
AVOID STORAGE IN ALUMINUM CONTAINERS OR CONTACT WITH ALUMINUM AND ZINC
POWDER.
Stability Condition to Avoid:AVOID EXPOSURES TO OPEN FLAMES, ARCS AND
HIGH TEMP.
Hazardous Decomposition Products:THERMAL - HYDROGEN CHLORIDE, CHLORINE
AND SOME PHOSGENE.

Disposal

Waste Disposal Methods:DISCARDED FILLED CANS OR PARTIALLY USED CANS ARE
HAZARDOUS WASTE. DISPOSE OF IN CONFORMANCE TO FEDERAL, STATE, AND
LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.