BNMVR - SODIUM PHOSPHATE P 32 SOLUTION

  • MSDS: BNMVR
  • Manufacturer: MALLINCKRODT MEDICAL INC
  • Product Name: SODIUM PHOSPHATE P 32 SOLUTION
  • National Stock Number: 6505-00N030331
Product Identification

Product ID:SODIUM PHOSPHATE P 32 SOLUTION
MSDS Date:01/01/1992
FSC:6505
NIIN:00N030331
MSDS Number: BNMVR

Responsible Party
MALLINCKRODT MEDICAL INC
2703 WAGNER PLACE
MARYLAND HEIGHTS, MO 63043
US

Emergency Phone: 314-344-3800

Info Phone: 314-344-3800

Cage: FO650

Contractor
MALLINCKRODT MEDICAL INC
MARYLAND HEIGHTS, MO 63043-3421 US

Telephone: 314-770-7800/314-895-2000

Cage: FO650

Ingredients

SODIUM PHOSPHATE P-32 (SARA III)

CAS: 7635-46-3

Fraction By Weight: <0.001%


ACETIC ACID, SODIUM SALT, (SODIUM ACETATE)

CAS: 127-09-3

RTECS: AJ4300010

Fraction By Weight: <1%


SODIUM CHLORIDE

CAS: 7647-14-5

RTECS: VZ4725000

Fraction By Weight: 0.9%


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 99%

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:HAZ NON RADIOACTIVE INGRED FOUND
IN SODIUM PHOSPHATE P-32 SOLUTION ARE SKIN & EYE IRRIT, BUT DUE TO
SMALL QTY PRESENT IN EACH CONTR, NO ADVERSE EFTS ARE EXPECTED TO
OCCUR FROM THESE COMPONENTS. INHAL:SOLIUM PHOSPHATE DOES NOT
EASILY BECOME AIRBORNE. NOT EXPECTED TO BE A HLTH HAZ. INGEST:MAY
(EFTS OF OVEREXPOS)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:CAUSE ASYMPTOMATIC PHYSIOLOGICAL
UPTAKE BY SPECIFIC TARGET ORGANS/TISSUE. SKIN:NOT EXPECTED TO
PRODUCE ANY ACUTE ADVERSE HLTH EFTS. EYE:MAY CAUSE MECH IRRIT.
CHRONIC:HLTH RISK ASSOC W/CHRONIC RADIATION EXPOS (CANCER,
LEUKEMIA, GENETIC & TERATOGENIC EFTS) ARE BELIEVED TO INVOLVE LEV
OF RADIATION EXPOS (SUPDAT)
Medical Cond Aggravated by Exposure:NO INFORMATION FOUND.

First Aid

First Aid:INHAL:NOT EXPECTED TO REQ FIRST AID MEASURES. INGEST:NOTIFY
RADIA SAFETY PERSONNEL IMMED. AMT OF MATL INGESTED SHOULD BE
ASSESSED & DOCUMENTED. SKIN:WASH AFFECTED AREA THORO W/SOAP & WATER
UNTIL NO MO RE RADIOACTIVITY CAN BE REMOVED. ALWAYSBLOT DRY. DO NOT
ABRADE SKIN. NOTIFY RADIA SAFETY PERSONNEL. EYE:WASH W/WATER FOR AT
LEAST 15 MIN/UNTIL NO MORE RADIOACTIVITY CAN BE REMOVED. NOTIFY
(SUPDAT)

Fire Fighting

Extinguishing Media:USE ANY MEANS SUITABLE FOR EXTINGUISHING
SURROUNDING FIRE.
Fire Fighting Procedures:NOT CONSIDERED TO BE A FIRE HAZARD. USE
NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NOT CONSIDERED TO BE A FIRE HAZARD.

Accidental Release

Spill Release Procedures:IF PROD IS RECIEVED IN LEAKING CONDTN/ANY
LOSS/RELEASE OF RADIOACTIVE CONTENTS OCCURS, NOTIFY RADIA SAFETY
DEPARTMENT & MALLINCKRODT AT (314)344-3800. ALL CLEANUP OPERATIONS
SHOULD BE PERFORMED ACCORD TO STANDARD OPERATING PROCEDURES
(SOP'S) (SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE AT 15-30C. HANDLING TIME SHOULD
BE KEPT TO MIN & APPROP SHIELDING SHOULD BE USED. HANDLING DEVICES
SUCH AS SYRINGE SHIELDS/TONGS SHOULD BE USED.
Other Precautions:STORAGE & DISP OF PROD SHOULD BE CONTROLLED IN MANNER
WHICH IS IN COMPLIANCE W/APPROP REGS OF FED/STATE GOVERNMENT AGENCY
AUTHORIZED TO LICENSE USE OF RADIONUCLIDE. VIAL CONTAINING DRUG
SHOULD BE KEPT WITHIN ITS CONTR/WITHIN(SUPDAT)

Exposure Controls

Respiratory Protection:NOT EXPECTED TO REQUIRE PERSONAL RESPIRATOR
USAGE. USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE
OF CONCERN .
Ventilation:PROPERLY SEALED CONTAINERS ARE NOT EXPECTED TO REQUIRE ANY
SPECIAL VENTILATION.
Protective Gloves:DISPOSABLE PLASTIC, LATEX/RUBBER GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NO SMOKING, EATING/DRINKING SHOULD BE ALLOWED
IN ANY AREA WHERE RADIOACTIVE MATERIALS ARE HANDLED OR STORED.
Supplemental Safety and Health
EFTS OF OVEREXPOS:WHICH ARE MUCH HIGHER THAN THOSE PERMITTED
OCCUPATIONALLY. FIRST AID PROC:RADIATION SAFETY PERSONEL. SPILL
PROC:ESTABLISHED FOR YOUR FACILITY. OTHER PREC:HEAVIER SHIELDING.
AVOID CON TACT WITH RADIOACTIVE CONTENTS WHICH WOULD CAUSE
UNNECESSARY EXPOSURE TO RADIATION.

Chemical Properties

HCC:A2
Boiling Pt:B.P. Text:212F,100C
Melt/Freeze Pt:M.P/F.P Text:32.0F,0.0C
Spec Gravity:285
Solubility in Water:SOLUBLE
Appearance and Odor:CLEAR COLORLESS LIQUID IN A 10 ML GLASS VIAL.
ODORLESS.

Stability

Stability Indicator/Materials to Avoid:YES
NO INFORMATION FOUND.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:MAY EMIT RADIOACTIVE FUMES CONTAINING
P-32 WHEN HEATED TO DECOMPOSITION.

Disposal

Waste Disposal Methods:RADIOACTIVE WASTE SHOULD BE DISPOSED OF
ACCORDING TO SOP'S ESTABLISHED BY YOUR RADIATION SAFETY OFFICER.
ENSURE COMPLIANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.