BNPWG - LEAD DRY CHARGED STORAGE BATTERY
- MSDS: BNPWG
- Manufacturer: CONCORDE BATTERY CORP
- Product Name: LEAD DRY CHARGED STORAGE BATTERY
- National Stock Number: 6140-01-123-2617
Product Identification
Product ID:LEAD DRY CHARGED STORAGE BATTERY
MSDS Date:01/01/1988
FSC:6140
NIIN:01-123-2617
MSDS Number: BNPWG
Responsible Party
WEST COVINA, CA 91790
US
Emergency Phone: 818-962-4006
Info Phone: 818-962-4006
Preparer: ED TORRES
Cage: 63017
Contractor
Telephone: 800-255-3924/818-813-1234
Cage: 63017
Ingredients
LEAD METAL.OSHA PEL AND ACGIH TLV ARE FOR INORGANIC DUST
CAS: 7439-92-1
RTECS: OF7525000
OSHA PEL 0.05 MG(PB)/M3
ACGIH TLV: 0.15 MG(PB)/M3
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
LEAD SULFATE.OSHA PEL AND ACGIH TLV FOR INORGANIC LEAD DUST
CAS: 7446-14-2
RTECS: OG4375000
OSHA PEL 0.05 MG(PB)/M3
ACGIH TLV: 0.15 MG(PB)/M3
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
LEAD OXIDE.ACGIH TLV FOR INORGANIC LEAD DUST AND FUME.
CAS: 1317-36-8
RTECS: OG1750000
OSHA PEL 0.05 MG(PB)/M3
ACGIH TLV: 0.15 MG(PB)/M3
SULFURIC ACID.LEAD COMPOUNDS ARE SATURATED WITH SULFURIC
CAS: 7664-93-9
RTECS: WS5600000
OSHA PEL 1 MG/M3
ACGIH TLV: 1 MG/M3
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
LD50 LC50 Mixture:N/K
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:SULFURIC ACID IS CORROSIVE.LEAD IS
KNOWN TO CAUSE REPRODUCTIVE DISORDERS (FEMALE,MALE AND/OR
DEVELOPMENTAL)(CAL PROP 65,1987).
Explanation of Carcinogenicity:INORGANIC LEAD AND LEAD COMPOUNDS:INADEQ
EVID FOR CARCIN IN HUMAND;SUFFICIENT EVID FOR CARCIN IN ANIMALS
(IARC 1987).
Effects of
Overexposure:EYES/SKIN:CORROSIVE.INGESTION:CORROSIVE.DIAGNOSIS OF
ACUTE LEAD POISONING MAY OCCUR WITH BLOOD LEVELS AS LOW AS 0.05
MG/M3 OR 60 MG/M3 OF WHOLE BLOOD.SIGNS ARE
WEAKNESS,LASSITUDE,INSOMNIA,WEIGHT LOSS AND PARALYSIS OF EXTENSOR
MUSCLES.INHALATION:CORROSIVE.
Medical Cond Aggravated by Exposure:N/K
First Aid
First Aid:EYES:FLUSH WITH LARGE AMOUNTS OF WATER FOR AT LEAST 15
MINUTES .SKIN:WASH WITH LARGE QUANTITIES OF WATER FOR 15
MINUTES.INGESTION/INHALATION:ACID PRECAUTIONS DO APPLY.
Fire Fighting
Flash Point:NONFLAMMABLE
Lower Limits:N/K
Upper Limits:N/K
Extinguishing Media:DRY CHEMICAL OR CARBON DIOXIDE SHOULD BE USED ON
FIRE.
Fire Fighting Procedures:USE FULL BODY PROTECTIVE CLOTHING AND FULL
FACEPIECE WITH SELF CONTAINED BREATHING APPARATUS OPERATED IN A
POSITIVE MODE.
Unusual Fire/Explosion Hazard:PRODUCT WILL BURN IN FIRE.LEAD OXIDE CAN
REACT VIGOROUSLY WITH STRONG OXIDIZING AGENTS AND WILL PRODUCE A
FUME,VAPOR & DUST THAT MAY BE TOXIC.COLOR:BLACK.
Accidental Release
Spill Release Procedures:DUST MATERIAL SHOULD BE VACUUMED,PARTICULATE
MATTER SHOULD BE STORED IN DRY CONTAINERS FOR DISPOSAL.DO NOT USE
COMPRESSED AIR OR DRY SWEEPING AS MEANS FOR CLEAN-UP.
Neutralizing Agent:N/K
Handling
Handling and Storage Precautions:LEAD COMPOUNDS ARE SATURATED WITH
SULFURIC ACID.ACID PRECAUTIONS DO APPLY.STORE IN A DRY LOCATION.
Other Precautions:USE PROPER AND ADEQUATE VENTILATION.
Exposure Controls
Respiratory Protection:USE DISPOSAL RESPIRATORS THAT ARE IN ACCORDANCE
WITH DUSTS,MISTS,AND FUME.
Ventilation:LOCAL EXHAUST.
Protective Gloves:RUBBER GLOVES.
Eye Protection:CHEMICAL SPLASH GOGGLES.
Other Protective Equipment:COVERALLS OR OTHER BODY CLOTHING SHALL BE
WORN DURING PRODUCT USAGE AND LAUNDERED.
Work Hygienic Practices:HYGIENE PRACTICES SHOULD BE FOLLOWED WITH OSHA
REGULATIONS AND GUIDELINES.
Supplemental Safety and Health
CONTRACT #:DAAK01-88-C-0061
Chemical Properties
HCC:N1
Decomp Temp:Decomp Text:N/K
Solubility in Water:INSOLUBLE
Appearance and Odor:BLACK PLASTIC BOX WITH NO ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
LEAD OXIDE CAN REACT VIGOROUSLY WITH STRONG OXIDIZING AGENTS TO PRODUCE
TOXIC FUME,VAPOR & DUST.
Stability Condition to Avoid:N/K
Hazardous Decomposition Products:PRODUCED ONLY IN A FIRE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.
Disposal
Waste Disposal Methods:DISP MUST BE IAW FED,STATE,& LOC
REGS.COORDINATION W/ SUPPORTING INSTALLATION/MACOM ENVIRONMENTAL
COORDINATION PRIOR TO DISP IS REC TO DETERM APPROPRIATE DISP METH
.SPENT BATTERIES SHOULD BE SEN T TO A LEAD SMELTER FOR DISPOSAL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.