Product Identification
Product ID:C5540, TE SOLVENT (LIQUID)
MSDS Date:06/01/1987
FSC:6850
NIIN:00N030122
MSDS Number: BPDQW
Responsible Party
KENNESAW, GA 30144
US
Emergency Phone: 404-424-4888
Info Phone: 404-424-4888
Preparer: S.H. STEIN
Cage: 2M589
Contractor
Telephone: 770-424-4888/800-645-5244
Cage: 2M589
Ingredients
(ORAL, RAT) 13,000 MG/KG.
CAS: 64-17-5
RTECS: KQ6300000
Fraction By Weight: 4%
OSHA PEL 1000 PPM
ACGIH TLV: 1000 PPM
(ORAL,
CAS: 76-13-1
RTECS: KJ4000000
Fraction By Weight: 95%
OSHA PEL 1000PPM;1250PPM STEL
ACGIH TLV: 1000PPM;1250PPM STEL
(ORAL, RAT) 1,210
CAS: 79-24-3
RTECS: KI5600000
Fraction By Weight: 1%
OSHA PEL 100 PPM
ACGIH TLV: 100 PPM
CAUSE DEFAT OF SKIN RSLTG IN IRRIT. MATL IS
RTECS: 9999999ZZ
EXPERIMENTAL ANIMALS, EXPOSURE AT APPROX 500 PPM
RTECS: 9999999ZZ
CHALLENGE, HAS INDUCED SERIOUS CARDIAC
RTECS: 9999999ZZ
IN 100 ML WATER). NEVER GIVE ANYTHING BY
RTECS: 9999999ZZ
ASPIRATING MATL INTO LUNGS IS A GREATER HAZ THAN
RTECS: 9999999ZZ
BECAUSE OF POSS INCREASED RISK OF
RTECS: 9999999ZZ
EPINEPHRINE, SHOULD BE CONSIDERED ONLY AS A LAST
RTECS: 9999999ZZ
WITH ANIMALS INDICATE ETHANOL MAY HAVE
RTECS: 9999999ZZ
RELEASED. MECHANICAL VENTILATION SHOULD BE USED IN
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:SEE INGREDIENTS
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CHLOROFLUOROCARBON (CFC) MATLS HAVE
PRDCD SENSIT OF THE MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS &
COULD HAVE A SIMILAR EFT IN HUMANS.ADRENOMIMETICS (E.G.,
EPINEPHRINE) MAY BE CONTRAINDICATED EXCEPT F OR LIFE-SUSTAINING
USES IN HUMANS ACUTELY/CHRONICALLY EXPOS TO CFC'S .(EFTS OF
OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:INHAL:VAP IS HVR THAN AIR & CAN CAUSE
SUFFOCATION BY REDUCING O*2 AVAILABLE FOR BRTHG. BRTHG HIGH CONC OF
VAP MAY CAUSE LIGHT-HEADEDNESS, GIDDINESS, SHORTNESS OF BRTH & MAY
LEAD TO NARCOSIS, CARDIAC IRREGULARITIES, UNCON/DEATH. EYE: CONT
MAY CAUSE IRRIT, SOLV CONTAINS ETHANOL. INGEST: ALTHOUGH (SUPP
DATA)
Medical Cond Aggravated by Exposure:INDIVIDUALS W/PREEXISTING DISEASES
OF LIVER, RETINA, CNS, GI TRACT/REPRODUCTIVE ORGANS MAY HAVE
INCREASED SUSCEPTIBILITY TO THE TOX OF EXCESSIVE EXPOSURES TO
ALCOHOLS IN THIS BLEND. TESTS (ING 11)
First Aid
First Aid:INHAL: EXCESSIVE VAP INHAL: MOVE TO FRESH AIR. IF NEC, GIVE
ARTF RESP/O*2. DO NOT GIVE EPINEPHRINE/SIMILAR DRUGS AS SUCH DRUGS
MAY INDUCE VENTRICULAR ARRHYTHMIA. EYE: IN CASE OF CONT, IMMED
FLUSH W/PL ENTY OF WATER FOR AT LEAST 15 MIN. CALLMD. SKIN: FLUSH
W/WATER. GET MED ATTN IF IRRIT IS PRESENT. INGEST: IMMED GIVE 2
GLASSES OF WATER OR ACTIVATED CHARCOAL SLURRY (50G ACTIVATED
CHARCOAL (ING 7)
Fire Fighting
Flash Point Method:TOC
Flash Point:NONE
Extinguishing Media:FOAM, CO2.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD PRESSURE DEMAND SCBA &
FULL PROT EQUIP . ADDITION OF EXCESS WATER WILL EXTRACT ALCOHOL &
MAY FORM A FLAMM, SUPERNATANT LIQ LAYER.
Unusual Fire/Explosion Hazard:PRESSURIZED AEROSOL CNTNRS AT ELEVATED
TEMPS MAY VENT, RUPTURE/BURST & ADD TO FLYING & FALLING
DEBRIS.INTENSE HEAT MAY CAUSE DECOMP W/EMISSION OF (SUPP DATA)
Accidental Release
Spill Release Procedures:VENTILATE AREA. REMOVE POSSIBLE IGNITION
SOURCES. WIPE UP SPILL AND ALLOW TO EVAPORATE. WASH HANDS WITH SOAP
AND WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:DO NOT STORE NEAR SOURCES OF HEAT, IN
DIRECT SUNLIGHT OR NEAR TEMPERATURES EXCEED 49C/120F. DO NOT
PUNCTURE OR DAM CONTAINERS. ROTATE STOCK.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN THE GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR
UV RADIATION MAY CAUSE THE FORMATION OF CHLORIDES, FLUORIDES AND/OR
PHOSGENE (FP N).
Exposure Controls
Respiratory Protection:UNDER NORMAL MANUFACTURING CONDITIONS, NO
RESPIRATORY PROTECTION IS REQUIRED WHEN USING THIS PRODUCT.
NIOSH/MSHA APPROVED SCBA IS REQUIRED IF A LARGE SPILL OCCURS.
Ventilation:NORM VENT FOR STANDARD MANUFACTURING PRECS IS GENERALLY
ADEQ. LOC EXHST SHLD BE USED WHEN LG AMTS ARE (ING 12)
Protective Gloves:BUTYL GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EXPLO HAZ: HALOGEN ACIDS. THERMAL DECOMP PRODS MAY INCLUDE CHLORIDES,
FLUORIDES & PHOSGENE . HAZ DECOMP PROD:HYDROFLUORIC ACIDS, POSSIBLY
CARBONYL HALIDES. HLTH HAZ:ORAL TOX OF MATL IS VERY LOW, INGEST OF
PROD IS TO BE AVOIDED. SKIN:NOT A CORR/IRRITANT AFTER SINGLE CONT.
HOWEVER, RPTD LIQ CONT CAN (ING 4)
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:112F,44C
Vapor Pres:362 @ 77F
Vapor Density:2.9 @ 77F
Spec Gravity:1.51 G/CC @ 77F
pH:NEUT
Evaporation Rate & Reference:0.5 (ETHER=1)
Solubility in Water:MODERATE
Appearance and Odor:CLEAR COLORLESS LIQUID; FAINT SOLVENT ODOR.
Percent Volatiles by Volume:100
Stability
Stability Indicator/Materials to Avoid:YES
ALKALI OR ALKALINE EARTH METALS - POWDERED AL, ZN, BE, ETC.
Stability Condition to Avoid:AVOID SPRAYING NEAR OPEN FLAMES AND HIGH
TEMPERATURES.
Hazardous Decomposition Products:COMPOUND CAN BE DECOMPOSED BY HIGH
TEMPS (OPEN FLAMES, GLOWING SURFS, ETC.) FORMING HYDROCHLORIC &
(SUPP DATA)
Disposal
Waste Disposal Methods:COMPLY WITH FEDERAL, STATE AND LOCAL
REGULATIONS. RECLAIM BY DISTILLATION OR REMOVE TO PERMITTED WASTE
DISPOSAL FACILITY.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.