BPFBV - M83769,BATTERY PRODUCTS,MILITARY AIR

Product Identification

Product ID:M83769,BATTERY PRODUCTS,MILITARY AIR
MSDS Date:05/23/1991
FSC:6140
NIIN:00-406-2633
MSDS Number: BPFBV

Responsible Party
TELEDYNE BATTERY PRODUCTS,A TELEDYNE INC CO
840 W BROCKTON AVE
REDLANDS, CA 92375
US

Emergency Phone: 714-793-3131,800-424-9300(CHEMTREC)

Info Phone: 714-793-3131

Preparer: GEORGE R.KINNARD

Cage: DO686

Contractor
TELEDYNE BATTERY PRODUCTS
431 REDLANDS, CA 92373 US

Telephone: 800-535-5053 (INFOTRAC)

Cage: DO686

Ingredients

LEAD (SARA III)

CAS: 7439-92-1

RTECS: OF7525000

Fraction By Weight: 26-35%

OSHA PEL 0.05 MG/M3;1910.1025

ACGIH TLV: 0.15 MG/M3;DUST 9192

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


LEAD OXIDE (SARA III)

CAS: 7439-92-1

RTECS: OF7525000

Fraction By Weight: 39-49%

OSHA PEL .05MG PB/M31910.1025

ACGIH TLV: .15 MG PB/M3 DUST 92

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


ANTIMONY (SARA III)

CAS: 7440-36-0

RTECS: CC4025000

Fraction By Weight: <1%

OSHA PEL 0.5 MG/M3

ACGIH TLV: 0.5 MG SB/M3; 9192

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ARSENIC (SARA III)

CAS: 7440-38-2

RTECS: CG0525000

Fraction By Weight: <0.10%

OSHA PEL 0.5 MG/M3 (AS)

ACGIH TLV: 0.01,A1 MG/M3; 9394

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


TIN

CAS: 7440-31-5

RTECS: XP7320000

Fraction By Weight: <1%

OSHA PEL 2 MG/M3

ACGIH TLV: 0.2 MG/M3; 9192


SULFURIC ACID (SARA III)

CAS: 7664-93-9

RTECS: WS5600000

Fraction By Weight: 25-26%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3; 9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

LD50 LC50 Mixture:LD50 (ORAL RAT) IS 2140 MG/KG (H2SO4)
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:EYES: SULFURIC ACID MAY CAUSE
IRRITATION,CORNEAL BURNS,CONJUCTIVITIS,SEVERE OR PERMANENT
INJURY,BLINDNESS. SKIN: ACID MAY CAUSE IRRITATION OR BURNS.
INHALATION: ACID CAN CAUSE BURNS OF NOSE/THROAT/UPP ER RESPIRATORY
TRACT AND LUNG IRRITATION,PULMONARY EDEMA. INGESTION:ACID MAY CAUSE
BURNS TO MOUTH,ESOPHAGUS AND STOMACH.
Explanation of Carcinogenicity:LEAD IS LISTED AS PROBABLY CARCINOGENIC
TO HUMANS BY NTP AND IARC.
Effects of Overexposure:EYES: IRRITATION, CORNEAL BURNS, CONJUCTIVITIS,
BLINDNESS. SKIN: IRRITATION, BURNS. INHALATION: NOSE, THROAT AND
BRONCHIAL TUBES IRRITATION AND CHRONIC INFLAMMATION, DIFFICULTY IN
BREATHING. INGESTION : BURNS TO MOUTH, ESOPHAGUS AND STOMACH.
Medical Cond Aggravated by Exposure:PERSONS WITH A HISTORY OF AILMENTS
OR WITH A PRE-EXISTING DISEASE INVOLVING THE EYES, SKIN OR
RESPIRATORY TRACT MAY BE AT INCREASED RISK FROM EXPOSURE.

First Aid

First Aid:EYES: FLUSH WITH LARGE AMOUNTS OF WATER. GET MEDICAL
ATTENTION. SKIN: REMOVE CONTAMINATED CLOTHING. WASH AREA WITH LARGE
AMOUNTS OF WATER. GET MEDICAL ATTENTION. INHALATION: MOVE TO FRESH
AIR. IF NOT BREATHING GIVE CPR. GET MEDICAL ATTENTION. INGESTION:
DO NOT INDUCE VOMITING. GIVE PATIENT LARGE AMOUNTS OF WATER IF
CONSCIOUS. GET MEDICAL ATTENTION.

Fire Fighting

Extinguishing Media:USE DRY CHEMICAL EXTINGUISHER. BATTERY CASE WILL
BURN.
Fire Fighting Procedures:USE OF WATER IN EXTINGUISHING BURNING
BATTERIES MAY CAUSE SPATTERING DUE TO THE PRESENCE OF MOLTEN LEAD.
WEAR SELF-CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:AFTER ELECTROLYTE IS ADDED AND BATTERY IS
BEING CHARGED, HYDROGEN GAS IS PRODUCED. BATTERY MAY EXPLODE IF
HYDROGEN GAS TRAPPED INSIDE THE CASE SHOULD IGNITE.

Accidental Release

Spill Release Procedures:SHOULD A BATTERY BREAK OPEN, ISOLATE AREA.
ELECTROLYTE SHOULD BE ABSORBED WITH A NON-ORGANIC TYPE ABSORBENT
SUCH AS DRY SAND OR EARTH. AVOID DILUTION WITH WATER. LEAD SPILLED
FROM THE BATTERY SHOULD B E VACUUMED, DO NOT SWEEP OR USE
COMPRESSED AIR.
Neutralizing Agent:USE SODA ASH OR BAKING SODA TO NEUTRALIZE THE
ELECTROLYTE.

Handling

Handling and Storage Precautions:AVOID THE USE OF UNINSULATED TOOLS. IF
THEY ARE REQUIRED, TAKE CARE NOT TO ELECTRICALLY SHORT THE
TERMINALS. REMOVE METAL JEWELRY BEFORE SERVICING.
Other Precautions:UNDER NORMAL CONDITIONS OF USE, EXPOSURE TO LEAD OR
LEAD CONTAINING COMPOUNDS DOES NOT OCCUR. SHOULD A BATTERY BREAK
OPEN AND A LEAD SPILL OCCURS, PRECAUTIONS SHOULD BE TAKEN TO
PREVENT LEAD DUST FROM BECOMING AIR BORNE.

Exposure Controls

Respiratory Protection:UNDER NORMAL CONDITIONS OF USE, RESPIRATORY
PROTECTION IS NOT REQUIRED. HOWEVER, IF CONDITIONS ARISE THAT
REQUIRE THEIR USE, USE ONLY NIOSH/MSHA RESPIRATORS APPROVED FOR
DUST, FUME AND MIST.
Ventilation:BATTERY CHARGING AREAS MUST BE ADEQUATELY VENTILATED TO
PREVENT HAZARDOUS CONCENTRATIONS OF FLAMMABLE GAS OR ACID MIST.
Protective Gloves:RUBBER GLOVES APPROVED FOR SULFURIC ACID
Eye Protection:CHEMICAL SPLASH GOGGLES AND FACE SHIELD
Other Protective Equipment:EYE WASH STATION AND SAFETY SHOWER.
INDUSTRIAL-TYPE IMPERVIOUS WORK CLOTHING, BOOTS AND APRON AS
REQUIRED.
Work Hygienic Practices:WASH AFTER HANDLING AND BEFORE EATING,
DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
MSDS DATA PRIMARILY WRITTEN FOR THE ELECTROLYTE; SULFURIC ACID. THE
ELECTROLYTE POSES THE GREATEST HAZARD DURING NORMAL OPERATIONS.
THIS LEAD ACID STORAGE BATTERY IS CLASSIFIED AS A MANUFACTURED
ARTIC LE (40 CFR 372.3). THE HAZARDOUS MATERIALS (LEAD, ANTIMONY
AND ARSENIC) ARE NOT RELEASED UNDER NORMAL CONDITIONS OF USE.

Chemical Properties

HCC:C1
Boiling Pt:=95.C, 203.F
B.P. Text:203F,95C
Vapor Pres:10 @18F
Vapor Density:>1
Spec Gravity:1.285
pH:1
Evaporation Rate & Reference:<1 (STD=UKNOWN)
Solubility in Water:COMPLETE
Appearance and Odor:NO ODOR. BATTERY CASE IS PINK OR TRANSLUCENT.
ELECTROLYTE IS CLEAR LIQUID.

Stability

Stability Indicator/Materials to Avoid:YES
CONTACT OF ELECTROLYTE WITH ORGANIC MATERIAL.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER. AVOID
OVERCHARGING.
Hazardous Decomposition Products:SULFURIC ACID MIST, SULFUR DIOXIDE AND
CARBON MONOXIDE MAY BE RELEASED WHEN ELECTROLYTE DECOMPOSES.

Disposal

Waste Disposal Methods:BOTH ELECTROLYTE AND SCRAP BATTERIES ARE
REGULATED HAZARDOUS WASTE. SCRAP BATTERIES CONTAIN MATERIALS WHICH
ARE RECYCLABLE AND MUST BE RETURNED TO AUTHORIZED RECYCLER.
ELECTROLYTE SHOULD BE HAULED TO A PERMITTED TREATMENT FACILITY.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.