BPKFC - SLIP-X 301

  • MSDS: BPKFC
  • Manufacturer: AMERICAN COLLOID CO
  • Product Name: SLIP-X 301
  • National Stock Number: 6850-00N032058
Product Identification

Product ID:SLIP-X 301
MSDS Date:03/28/1990
FSC:6850
NIIN:00N032058
MSDS Number: BPKFC

Responsible Party
AMERICAN COLLOID CO
ONE NORTH ARLINGTON 1500 WEST SHURE DR
ARLINGTON HEIGHTS, IL 60004-1434
US

Emergency Phone: 708-392-4600

Info Phone: 708-392-4600

Cage: 84066

Contractor
AMERICAN COLLOID COMPANY
ARLINGTON HEIGHTS, IL 60004-1434 US

Telephone: 312-392-4600

Cage: 84066

Ingredients

ETHYLENE GLYCOL (SARA III)

CAS: 107-21-1

RTECS: KW2975000

Fraction By Weight: 16-50%

OSHA PEL 50 PPM, C

ACGIH TLV: 50 PPM VAP/MIST, C

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


BENTONITE

CAS: 1302-78-9

RTECS: CT9450000

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: CAN CAUSE IRRIT. SKIN: CAN CAUSE
SLIGHT IRRITATION. INHAL: EXCESSIVE INHAL OF VAPS CAN CAUSE NASAL &
RESP IRRIT. INGEST: CAN CAUSE GI IRRIT, NAUS, VOMIT & DIARR.
ETHYLENE GLYCOL HAS BEEN SHOWN T O PRODUCE DOSE-RELATED TERATOGENIC
EFFECTS IN RATS & MICE WHEN GIVEN BY GAVAGE/IN DRINKING WATER AT
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: HIGH CONC. WHILE THERE IS NO
CURRENTLY AVAIL INFORMATION TO SUGGEST THAT ETHYLENE GLYCOL HAS
CAUSED BIRTH DEFECTS IN HUMANS IT IS RECOMMENDED THAT EVERY EFFORT
SHOULD BE MADE TO PVNT INGEST OF ANY ETHYLENE GLYCOL & TO KEEP
PERSONNEL EXPOSURE BELOW ACGIH TLV. HAS BEEN SUGGESTED AS CAUSE OF
LIVER (SUPP DATA)
Medical Cond Aggravated by Exposure:NONE KNOWN.

First Aid

First Aid:EYES: FLUSH WITH WATER FOR AT LEAST 15 MIN. SKIN: THOROUGHLY
WASH EXPOSED AREA WITH SOAP AND WATER, REMOVE CONTAMINATED
CLOTHING. INGEST: IMMEDIATELY DRINK 2 GLASSES OF WATER AND INDUCE
VOMITING. GET MEDICAL ATTENTION. NEVER GIVE ANYTHING BY MOUTH TO
AN UNCONSCIOUS PERSON.

Fire Fighting

Flash Point:240F,116C
Lower Limits:3.2%
Extinguishing Media:WATER, FOG, CO2, OR DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE KNOWN.

Accidental Release

Spill Release Procedures:SML SPILL:ABSORB LIQUID ON PAPER, VERMICULITE,
FLOOR ABSORBENT, OR OTHER ABSORB MATL & TRANSFER TO HOOD. LRG
SPILL:ELIM ALL IGNIT SOURCES. PERSONS NOT WEARING PROT EQUIP SHOULD
BE EXCLUDED FROM AREA O F SPILL UNTIL CLEAN-UP HAS BEEN (SUPP DATA)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID REPEATED OR PROLONGED CONTACT
WITH SKIN.
Other Precautions:SLIPPERY CHARACTERISTIC CAN CAUSE FALLS IF SPILLS NOT
EFFECTIVELY CLEANED UP.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR IF TLV IS
LIKELY TO BE EXCEEDED.
Ventilation:LOCAL OR MECHANICAL (GENERAL): AS APPROPRIATE
Protective Gloves:NITRILE RUBBER
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:WEAR IMPERVIOUS CLOTHING AND BOOTS TO
PREVENT REPEATED OR PROLONGED SKIN CONTACT.
Work Hygienic Practices:USE GOOD HOUSEKEEPING PRACTICES.
Supplemental Safety and Health
SPILL PROC: COMPLETED. STOP SPILL AT SOURCE, DIKE AREA OF SPILL TO
PREVENT SPREADING, PUMP LIQUID TO SALVAGE TANK. REMAINING LIQUID
MAY BE TAKEN UP ON SAND, CLAY, EARTH, FLOOR ABSORBENT, OR OTHER
ABSO RBENT MATERIAL AND SHOVELED INTO CONTAINERS. EFTS OF OVEREXP:
ABNORMALITIES, KIDNEY DAMAGE, CNS EFFECTS IN HUMANS.

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:400F,204C
Vapor Pres:<0.1 @ 68F
Vapor Density:2.2
Spec Gravity:1.3-2.0(H2O=1)
Evaporation Rate & Reference:< 1 (BUTYL ACETATE=1)
Solubility in Water:100%
Appearance and Odor:YELLOW VISCOUS LIQUID.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:WHEN BURNED MAY FORM CO2 AND CO, ETC.

Disposal

Waste Disposal Methods:FOLLOW FEDERAL, STATE AND LOCAL REGULATIONS FOR
DISPOSAL.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.