BPLZB - 31051, 31-051 SEMI-GLOSS CATACLEAR

  • MSDS: BPLZB
  • Manufacturer: RUDD CO INC
  • Product Name: 31051, 31-051 SEMI-GLOSS CATACLEAR
  • National Stock Number: 8010-00N033314
Product Identification

Product ID:31051, 31-051 SEMI-GLOSS CATACLEAR
MSDS Date:05/15/1986
FSC:8010
NIIN:00N033314
MSDS Number: BPLZB

Responsible Party
RUDD CO INC
1630 15TH AVE WEST
SEATTLE, WA 98119
US

Emergency Phone: 206-284-5400

Info Phone: 206-284-5400

Cage: 0VKG8

Contractor
RUDD COMPANY INC.
SEATTLE, WA 98119-2717 US

Telephone: 206-284-5400/800-424-9300(CHEMTREC)

Cage: 02958

Ingredients

70 @ 20C.

CAS: 78-93-3

RTECS: EL6475000

Fraction By Weight: <0.5%

OSHA PEL 200 PPM;300 PPM STEL

ACGIH TLV: 200 PPM;300 PPM STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


96 @ 20C.

CAS: 67-56-1

RTECS: PC1400000

Fraction By Weight: <5%

OSHA PEL S,200PPM/250STEL

ACGIH TLV: S,200PPM/250STEL; 93

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


ACETIC ACID, ETHYL ESTER; (ETHYL ACETATE) (SARA III).

CAS: 141-78-6

RTECS: AH5425000

Fraction By Weight: <0.5%

OSHA PEL 400 PPM

ACGIH TLV: 400 PPM

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


2-PENTANONE, 4-METHYL-; (METHYL ISOBUTYL KETONE) (SARA

CAS: 108-10-1

RTECS: SA9275000

Fraction By Weight: <5%

OSHA PEL 100 PPM/75 STEL

ACGIH TLV: 50 PPM/75 STEL; 9293

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


2 @ 20C.

CAS: 8006-61-9

RTECS: LX3300000

Fraction By Weight: <0.5%

OSHA PEL 300 PPM;500 PPM STEL

ACGIH TLV: 300 PPM;500 PPM STEL


7 @ 20C.

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 25%

OSHA PEL 100 PPM;150 PPM STEL

ACGIH TLV: 100 PPM;150 PPM STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


40 @ 20C.

CAS: 64-17-5

RTECS: KQ6300000

Fraction By Weight: 15%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM


5.5 @ 20C.

CAS: 71-36-3

RTECS: EO1400000

Fraction By Weight: 10%

OSHA PEL 100 PPM

ACGIH TLV: S, C 50 PPM; 9293

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


1 @ 20C.

CAS: 50-00-0

RTECS: LP8925000

Fraction By Weight: 0.58%

OSHA PEL SEE 1910.1048

ACGIH TLV: C 0.3 PPM; A2; 9293

EPA Report Quantity: 100 LBS

DOT Report Quantity: 100 LBS


ETHANOL, 2-PROPOXY; (ETHYLENE GLYCOL MONOPROPYL ETHER).

CAS: 2807-30-9

RTECS: KM2800000

Fraction By Weight: <5%

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:ACUTE:INHAL:CNS DEPRESSION FROM
PROLONGED EXPOSURE TO HIGH CONCENTRATION CAUSES HEADACHE,
DIZZINESS, APPETITE LOSS, COORDINATION LOSS, WEAKNESS.
SKIN/EYE/INGEST:MINOR IRRITANT, NOT EXPECTED TO BE TOXI C.
CHRONIC:REPEATED EXPOSURE DEFATS SKIN. CHEMICAL CARCIOGENIC
POTENTIAL:FORMALDEHYDE, HUMAN UNCERTAIN.(EFTS OF OVEREXP)
Explanation of Carcinogenicity:FORMADEHYDE:GROUP 2A (IARC), ANTICIPATED
TO BE CARCINOGEN (NTP), OSHA REGULATED; GASOLINE:GROUP 2B (IARC).
Effects of Overexposure:HLTH HAZ:IN CHRONIC INHALATION STUDIES, HIGH
CONCENTRATIONS CAUSE NASAL CANCER IN LABORATORY RATS.
Medical Cond Aggravated by Exposure:ANESTHESIA, RESPIRATORY TRACT
IRRITATION, DERMATITIS, NAUSEA.

First Aid

First Aid:INGEST:CALL MD IMMEDIATELY . INHAL:REMOVE FROM EXPOSURE,
RESTORE BREATHING, CALL MD. SKIN:FLUSH IMMED W/COPIOUS AMOUNTS OF
WATER FOR AT LEAST 15 MINUTES. CALL MD. EYES:FLUSH IMMED W/COPIOUS
AMOU NT OF WATER FOR AT LEAST 15 MINUTES. CALL MD.

Fire Fighting

Flash Point:54.0F,12.2C
Lower Limits:1%
Extinguishing Media:FOAM, CO*2, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
. WATER SPRAY MAY BE INEFT. WATER SPRAY, PREF FOG, MAY BE USED TO
COOL UNRUPTURED CNTNRS.
Unusual Fire/Explosion Hazard:DANGEROUS WHEN EXPOSED TO HEAT/FLAME. CAN
REACT VIGOROUSLY W/OXIDIZING AGENTS. WATER STREAM WILL SPREAD OIL
FIRES, FIGHT LIKE GASOLINE FLASH OIL FIRE.

Accidental Release

Spill Release Procedures:ELIMINATE IGNITION SOURCES, VENTILATE AREA
WELL, REMOVE SPILL W/INERT ABSORBENT MATERIAL & NON-SPARKING
(ALUMINUM, BRASS OR COPPER) TOOLS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT STORE >120F. DO NOT PUNCTURE.
AVOID HOT METAL SURFACES.
Other Precautions:DO NOT APPLY NEAR FIRE, SPARK OR OPEN FLAME. KEEP OUT
OF REACH OF CHILDREN. INTENTIONAL MISUSE BY DELIBERATELY
CONCENTRATING & INHALING CONTENTS CAN BE HARMFUL/FATAL.

Exposure Controls

Respiratory Protection:OUTDOOR/OPEN AREAS:USE NIOSH/MSHA APPRVD MECH
FILTER RESP TO REMOVE SOLID AIRBORNE PARTICLES OF OVERSPRAY. IN
RESTRICTED VENT AREAS:USE NIOSH/MSHA APPRVD CARTRIDGE RESP TO KEEP
MISTS & VAPS BELOW TLVS . IN CONFINED AREAS:USE NIOSH/ (SUPDAT)
Ventilation:PROVIDE GEN MECH VENT OR LOC EXHST TO KEEP VAP CONCS BELOW
TLV OF MATLS IN INGS SECT & LEL IN FIRE & EXPLO HAZ SECT.
Protective Gloves:IMPERMEABLE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:USE PROT CLTHG TO PVNT SKIN CONT. USE HEAD
CAPS WHEN NEC. EYE WASHES & SAFETY SHOWERS IN WORKPLACE ARE RECOM.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
RESP PROT:MSHA APPRVD FRESH-AIR SUPPLYING RESP OR SCBA.

Chemical Properties

Boiling Pt:B.P. Text:>165F,>74C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:65.19

Stability

Stability Indicator/Materials to Avoid:YES
OXIDIZING MATERIALS.
Stability Condition to Avoid:DO NOT STORE >120F, POOR VENT, CONC VAPS,
INGEST.
Hazardous Decomposition Products:CO, CO*2, IRRITATING FUMES, SMOKE.

Disposal

Waste Disposal Methods:COLLECT ABSORBENT/SPILL MIXTURE INTO METAL
CONTAINERS & ADD ENOUGH WATER TO COVER. DISPOSE OF ACCORDING TO
LOCAL, STATE & FEDERAL REGULATIONS. DO NOT INCINERATE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.